Demonstration of mitral valve function by cine computed tomography using a new long axis view.

Comparison was made between contrast enhanced cine computed tomography (Cine/CT) and echocardiography in the imaging of the mitral valve in 14 patients. The mitral valve was seen in all 14 patients by Cine/CT using a new long axis view. There was agreement with echocardiography in 12 patients. Abnormalities in mitral valve movement were detected by Cine/CT. Left atrial size and contraction was measured by Cine/CT with a difference in left atrial ejection fraction observed between 13 patients with no evidence of mitral disease and 3 patients with mitral disease.

Adult↗

Comparison of left ventricular ejection fraction by cine computed tomography and single plane right anterior oblique ventriculography.

Cine Computed Tomography (CCT) is a minimally invasive technique which offers high temporal (50 msec scan time) and spatial (2 line pairs) resolution. Left ventricular ejection fraction (LVEF) has been determined by this technique in dogs and normal subjects but no comparison has been made with contrast left ventriculography by cardiac catheterization. Ten patients, 9 male and 1 female, mean age 61 (range 46-70) had LVEF determined by both single plane RAO left ventriculography and CCT. Patients were studied in the fasting state, on different days without change in medication. LVEF by CCT was determined in the long axis, a new view which has been developed for CCT to be comparable to the RAO view of contrast left ventriculography by catheterization. This view is obtained by positioning the patient head first into the scanner, supine, with a counterclockwise table slew (20 degrees) without table tilt. Contrast is introduced via a median antecubital vein, and injected in a prolonged bolus of 7-13 seconds dependent on arm to heart circulation time. Scans are performed in the cine mode (17 frames/sec) timed during maximal opacification of the right and left ventricles. Four or six contiguous levels are imaged as required to slice the entire left ventricular cavity. End-systolic and end-diastolic frames are identified. Left ventricular cavity areas are determined by computerized planimetry after the Hounsfield level number is set at half the difference between the contrast in the cavity and the myocardium and setting the window width at one giving a black and white image. Left ventricular end-diastolic volume (LVEDV) and end-systolic volume (LVESV) per slice are summated to obtain LVEDV and LVESV from which LVEF is desired.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Rapid acquisition computed tomographic assessment of left ventricular regional wall motion using a new long axis view.

A long axis view to demonstrate left ventricular regional wall motion was devised for the ultrafast CT scanner. The patients are positioned supine, head first, into the scanner. The scan table is slewed 20 degrees counter-clockwise in the horizontal plane without tilt. A bolus of contrast is injected via a median antecubital vein. Contiguous level R wave triggered cine studies are obtained during peak passage of contrast through the heart to image the entire left ventricular cavity. Fourteen patients had left ventricular wall motion compared by long axis CT and RAO 30 degrees single plane ventriculography at catheterization. In all cases, regional wall motion in comparable segments by both methods was in agreement. It is concluded that the ultrafast CT long axis view permits diagnosis of left ventricular regional wall motion abnormalities. This view images the apex and sections the interventricular septum and lateral free wall horizontally. Unlike conventional CT views, it is comparable to the RAO left ventriculogram.

Cardiac Catheterization↗

The effect of beta-adrenoceptor agonists and antagonists on gastric emptying in man.

1. The effect of beta-adrenoceptor agonists and antagonists on gastric emptying of a solid meal labelled with Indium113m was measured by a gamma camera in healthy volunteers or patients with hypertension. Each subject acted as his own control. 2 In ten subjects given isoprenaline (10 or 20 mg) sublingually 30 min before the meal, gastric emptying half-times were significantly prolonged (P less than 0.05). No effect was observed when isoprenaline was given immediately before the meal. 3 Salbutamol, 4 mg four times daily for 1 week also significantly prolonged gastric emptying in four subjects (P less than 0.05). 4 The effect of isoprenaline on gastric emptying was blocked by propranolol 40 mg four times daily for 1 week. 5 In ten subjects propranolol 40 mg four times daily alone for 1 week was found to significantly speed up gastric emptying (P less than 0.005), suggesting that emptying of the normal stomach is subject to some degree of adrenergic inhibition.

Adrenergic beta-Agonists↗

The effect on paracetamol absorption of stimulation and blockade of beta-adrenoceptors.

1 The effect of drugs acting on beta-adrenoceptors on the absorption and excretion of paracetamol was studied in 26 volunteers and nine patients with mild hypertension, each subject acting as his/her own control. 2 Isoprenaline given 30 min before paracetamol significantly slowed absorption, the effect being dose related, and blocked by prior administration of propranolol. 3 When isoprenaline was given immediately before the paracetamol, absorption was not altered, although a cardiovascular response was seen. 4 Oral salbutamol also delayed paracetamol absorption. 5 Propranolol given alone increased the rate of paracetamol absorption. 6 These results with the changes in the rate of gastric emptying produced by these agents.

Acetaminophen↗

Does the Kensey catheter keep a coaxial position inside the arterial lumen? An in-vitro angioscopic study.

Angioscopy was used to evaluate the "self-centering" ability of three Kensey catheters (KC) with different flexibility: one 8Fr "peripheral" and two 5Fr "coronary" (I & II). Angioscopic observations were made inside arteries, 5-18 mm in diameter. There was a good correlation between flexibility and self-centering of the KC [r = 0.83, p less than 0.05]. Increasing the flow rate of rinsing solution from 18 to 60 ml/min prolonged coaxial position from 8.9 +/- 3.3 to 36 +/- 2.2 sec/min of activation [p less than 0.001]. A smaller effect on coaxial position was exerted by increasing cam speed from 5.2 +/- 0.7 to 19.2 +/- 1.6 sec/min (p less than 0.001). In conclusion, angioscopy showed that the KC has a limited ability to maintain a coaxial position inside the arterial lumen and operators cannot rely on its self-centering property.

Angioplasty, Balloon, Coronary↗

Treatment of acute lower limb ischemia following the use of the Duett sealing device: report of three cases and review of the literature.

Three cases of local thrombolysis in the treatment of acute lower limb ischemia complicating the utilization of the Duett sealing device are presented. Routine usage of several vascular closure devices after cardiac catheterization and percutaneous coronary intervention (PCI) has been adopted in our institution during the last 3 years (September 1999 to April 2003). The Duett closure device has been used in 420 patients (post-coronary angiography, 359; post-PCI, 61). Three patients (0.7%) demonstrated acute leg ischemia used by inadvertent intravascular administration of the sealing material related to this device. All three were treated successfully by catheter-directed local thromolysis (tissue plasminogen activator 5 mg bolus followed initially by 1 mg/hr and consequently by 0.5-1.0 mg/hr depending upon the development of significant hematoma and lasting for 24 hr). In conclusion, interventional treatment using local thrombolysis should be the first-line treatment in acute lower limb ischemia complicating the utilization of the Duett sealing device.

Acute Disease↗

Can rotational atherectomy cause thermal tissue damage? A study of the potential heating and thermal tissue effects of a rotational atherectomy device.

PURPOSE: Thermal tissue damage (TTD) is customarily associated with some lasers. The thermal potential of rotational atherectomy (RA) devices is unknown. We investigated the temperature profile and potential TTD as well as the value of fluid flushing of an RA device. METHODS: We used a high-resolution infrared imaging system that can detect changes as small as 0.1 degree C to measure the temperature changes at the tip of a fast RA device with and without fluid flushing. To assess TTD, segments of porcine aorta were subjected to the rotating tip under controlled conditions, stained by a special histochemical stain (picrisirius red) and examined under normal and polarized light microscopy. RESULTS: There was significant heating of the rotating cam. The mean "peak" temperature rise was 52.8 +/- 16.9 degrees C. This was related to rotational speed; thus the "peak" temperature rise was 88.3 +/- 12.6 degrees C at 80,000 rpm and 17.3 +/- 3.8 degrees C at 20,000 rpm (p < 0.001, t-test). Fluid flushing at 18 ml/min reduced, but did not abolish, heating of the device (11.8 +/- 2.9 degrees C). A crater was observed in all segments exposed to the rotating tip. The following features were most notable: (i) A zone of "thermal" tissue damage extended radially from the crater reaching adventitia in some sections, especially at high speeds. This zone showed markedly reduced or absent birefringence. (ii) Fluid flushing of the catheter reduced the above changes but increased the incidence and extent of dissections in the media, especially when combined with high atherectomy speeds. (iii) These changes were observed in five of six specimens exposed to RA without flushing, but in only one of six with flushing (p < 0.05). (iv) None of the above changes was seen in control segments. CONCLUSION: RA is capable of generating significant heat and potential TTD. Fluid flushing reduced heating and TTD. These findings warrant further studies in vivo, and may influence the design of atherectomy devices.

Analysis of Variance↗

Cine-computed tomography of cor triatriatum.

A case of cor triatriatum in a 51-year-old man was demonstrated by rapid acquisition cine-CT (CCT). The CCT findings are compared with cardiac catheterization and two-dimensional echocardiography.

Cineradiography↗