Anatomical model matching with fuzzy implicit surfaces for segmentation of thoracic volume scans.

Many segmentation methods for thoracic volume data require manual input in the form of a seed point, initial contour, volume of interest etc. The aim of the work presented here is to further automate this segmentation initialization step. In this paper an anatomical modeling and matching method is proposed to coarsely segment thoracic volume data into anatomically labeled regions. An anatomical model of the thorax is constructed in two steps: 1) individual organs are modeled with blended fuzzy implicit surfaces and 2) the single organ models are grouped into a tree structure with a solid modeling technique named constructive solid geometry (CSG). The combination of CSG with fuzzy implicit surfaces allows a hierarchical scene description by means of a boundary model, which characterizes the scene volume as a boundary potential function. From this boundary potential, an energy function is defined which is minimal when the model is registered to the tissue-air transitions in thoracic magnetic resonance imaging (MRI) data. This allows automatic registration in three steps: feature detection, initial positioning and energy minimization. The model matching has been validated in phantom simulations and on 15 clinical thoracic volume scans from different subjects. In 13 of these sets the matching method accurately partitioned the image volumes into a set of volumes of interest for the heart, lungs, cardiac ventricles, and thorax outlines. The method is applicable to segmentation of various types of thoracic MR-images, provided that a large part of the thorax is contained in the image volume.

Heart↗

A model for the modulation transfer function of cardiovascular x-ray systems.

RATIONALE AND OBJECTIVES: To derive a theoretical model for the modulation transfer function (MTF) of the complete imaging chain of a cardiovascular x-ray system. A sufficiently accurate MTF model may be used in quantitative coronary arteriographic applications to decrease the systematic overestimation of small coronary vessels. The model could be used to restore blurred images in image restoration applications and also may be used for image quality assurance measurements. METHODS: Digital images of a step wedge phantom were acquired at different modes (5-, 7-, and 9-inch) of the image intensifier and at different kilovolt levels of the x-ray generator. From these images the MTFs that were used to estimate the parameters of the model were assessed. RESULTS: The total MTF of the cardiovascular x-ray imaging chain consisting of image intensifier, video camera, optical elements, and analog/digital converter can be modeled by the simple formula MTF = e-(w/f)R, where w is the frequency in linepairs per millimeter. The constants frequency f and the device index n are parameters that can be derived for an individual x-ray system using the phantom. In this formula, the contribution from the focus of the x-ray source has been excluded. The mean square error (MSE) between the measured values and those assessed from the theoretical model of the MTF for the horizontal direction was found to be equal to 0.00003 for the 5-inch mode of image intensifier, and for the vertical resolution at the 9-inch mode this MSE was equal to 0.00038. In addition, we have demonstrated that the contributions of the video camera and the image intensifier to the total MTF can be replaced by an imaginary electron-optical device. CONCLUSION: An accurate representation for the MTF of a cardiovascular x-ray system has been derived. This MTF model can be used in x-ray image quality assurance measurements and in quantitative image processing applications.

Cardiovascular System↗