PubMed Health⌕ Search

Biomedical subjects

M R Stacey

Publications and source records attributed to M R Stacey.

17 recordsLinked to original sources

Comparison of face masks in the bag-mask ventilation of a manikin.

BACKGROUND AND OBJECTIVE: We conducted a study investigating the effectiveness of four face mask designs in the bag-mask ventilation of a special manikin adapted to simulate a difficult airway. METHODS: Forty-eight anaesthetists volunteered to bag-mask ventilate the manikin for 3 min with four different face masks. The primary outcome of the study was to calculate mean percentage leak from the face masks over 3 min. Anaesthetists were also asked to rate the face masks using a visual analogue score. RESULTS: The single-use scented intersurgical face mask had the lowest mean leak (20%). This was significantly lower than the mean leak from the single-use, cushioned 7,000 series Air Safety Ltd. face mask (24%) and the reusable silicone Laerdal face mask (27%) but not significantly lower than the mean leak from the reusable anatomical intersurgical face mask (23%). CONCLUSIONS: There was a large variation in both performance and satisfaction between anaesthetists with each design. This highlights the importance of having a variety of face masks available for emergency use.

Anesthesia↗

A comparison of direct laryngoscopy and jaw thrust to aid fibreoptic intubation.

We compared two manoeuvres, jaw thrust and laryngoscopy, to open the airway during fibreoptic intubation in 50 patients after induction of anaesthesia in a crossover study. Patients were randomly allocated to receive either jaw thrust or conventional Macintosh laryngoscopy first. Airway clearance was assessed at both the soft palate and the epiglottis. Direct laryngoscopy provided significantly better airway clearance at the level of the soft palate than jaw thrust (44 (88%) vs 31 (62%), respectively; p = 0.002). At the level of the larynx, airway clearance was equally good in both groups (45 (90%) vs 46 (92%), respectively; p = 0.56). The times to view the larynx (median (interquartile range [range]) 4 (3-5 [2-35]) s vs 3 (3-4 [2-8]) s, respectively) and intubation time (20 (17-23 [11-83]) s vs 18 (15-20 [11-28]) s, respectively) were also similar.

Adult↗

An evaluation of the modified Airway Management Device.

We evaluated the modified Airway Management Device (AMDTM) in 60 spontaneously breathing anaesthetised patients. The insertion and removal of the device was very easy and atraumatic. The airway was secured on the first attempt in 41 patients (70%; 95% CI 57-80%). The most important problem was loss of airway, which occurred in 11 patients (19%; 11-30%) during maintenance of anaesthesia. The AMD was dislodged during maintenance in one patient. There was a loss of the airway in 12 patients (20%; 12-31%); in 10, it was maintained with simple airway manoeuvres or a laryngeal mask airway and tracheal intubation was required in two patients. Ten of these patients were male and two were female; the failure rate was 33% (12-31%) among the male patients and 6% (2-22%) among the female patients. The cuff volumes ranged from 4 ml to 80 ml and cuff pressures from 6 cm H2O to 92 cm H2O. Blood was seen on removal in three patients (6%; 2-16%) and nine patients (18%; 10-30%) experienced sore throat after removal of the device.

Adult↗

Thyroplasty under general anesthesia using a laryngeal mask airway and fibreoptic bronchoscope.

PURPOSE: To report the management of a patient, with unilateral vocal cord paralysis, undergoing thyroplasty, under general anesthesia. CLINICAL FEATURES: A 25-yr-old man developed hoarseness and occasional episodes of pulmonary aspiration, caused by unilateral vocal cord paralysis. He was scheduled for thyroplasty, in an attempt to ease phonation and to decrease or prevent further episodes of pulmonary aspiration. He refused local anesthesia with sedation and it was therefore decided to attempt the procedure under general anesthesia. The paralysed vocal cord was displaced inwards by a wedge inserted through a window in the thyroid cartilage. We assessed the ideal position of the wedge by using a fibreoptic bronchoscope and laryngeal mask airway during general anesthesia, instead of phonation. CONCLUSION: We describe the successful use of a general anesthetic for a thyroplasty, a procedure normally done under local anesthesia with or without sedation, in a patient who was keen to have surgery, but who refused local anesthesia with sedation.

Adult↗

Topical ibuprofen for skin analgesia prior to venepuncture.

The analgesic effect of topical ibuprofen was investigated in ten volunteers. There were no significant differences in visual analogue scale pain scores for pinprick after 15 and 60 min of application of ibuprofen, placebo and EMLA cream. Comparison of visual analogue scale scores for venous cannulation after similar durations of ibuprofen and EMLA creams found significantly (p < 0.014) lower scores for EMLA at 60 min. We do not consider ibuprofen cream to be clinically useful for venous cannulation.

Administration, Topical↗

Use of the laryngeal mask for closed circuit anesthesia.

We examined whether the laryngeal mask could be used effectively in 70 patients breathings spontaneously during closed-circuit anesthesia. After administration of oxygen 101.min-1, anesthesia was induced and the laryngeal mask inserted. After 6 min of denitrogenation (3.51.min-1 nitrous oxide and 1.51.min-1 oxygen), the fresh-gas flow was decreased to the minimum required to maintain refilling of a ventilator bellows (Carden Ventmasta); nitrous oxide was turned off. A vaporiser outside the breathing system was set either by observing an end-tidal agent monitor or at 3-5 times greater than the required end-tidal concentration. The total fresh gas flow, hemodynamics and respiratory variables were monitored. Several types of operations were performed and lasted 9-126 min (mean 37 min). The average total fresh gas flow during the closed circuit period was 340 ml.min-1 (range 200-500 ml.min-1). Blood pressure, heart rate and respiration were stable throughout anesthesia and there were no major side effects attributable to the technique. We believe that closed-circuit anesthesia in patients breathing spontaneously through the laryngeal mask, as described here, can be used safely, conveniently and effectively. This technique is suitable for surgical operations of short duration.

Adolescent↗

Effects of magnesium sulphate on suxamethonium-induced complications during rapid-sequence induction of anaesthesia.

Twenty patients were studied in a double-blind manner to investigate whether magnesium sulphate, when given during a rapid-sequence induction of anaesthesia, lessens the side effects caused by suxamethonium. Patients were randomly allocated to two groups; equal volumes of either magnesium sulphate (40 mg.kg-1) or saline were given during rapid-sequence induction of anaesthesia, after thiopentone but before the administration of suxamethonium (1.5 mg.kg-1). The changes in the serum potassium concentration, the degree of muscle fasciculations and the presence of postoperative myalgia were recorded. The mean serum potassium concentration increased by 0.08 mmol.l-1 in the magnesium group and by 0.1 mmol.l-1 in the control group at 2 min after injection of suxamethonium; in neither group was there a significant increase from baseline values. The systolic blood pressure and heart rate increased in both groups after tracheal intubation. The incidence of fasciculations was significantly lower in the magnesium group. Magnesium did not clinically prolong muscle relaxation. There was no difference between the groups in the incidence of myalgia after surgery (one patient in each group). Since no significant increase in the serum potassium concentration was demonstrated, no assessment could be made of the effect of magnesium sulphate on the serum potassium concentration after administration of suxamethonium.

Adolescent↗