PubMed Health⌕ Search

Biomedical subjects

M Rabuffetti

Publications and source records attributed to M Rabuffetti.

At least 19 recordsLinked to original sources

Real-time human motion estimation using biomechanical models and non-linear state-space filters.

In the field of sports biomechanics and rehabilitation engineering, the possibility of computing, in real time, the angular displacements and derivatives of human joints, from a video of motion sequences, represents an appealing goal. In particular, applications of biofeedback protocols in rehabilitation can benefit from this capability. The focus of the investigation was concerned with the application of biomechanical models, comprising of a kinematic chain and surface envelopes, and state-space filters, to the computation, in real time and with high accuracy, of the angular data and derivatives. By minimising the distances, measured with TV cameras, between the 2D marker projections and the corresponding back-projected markers located on the mannequin, the configuration of the biomechanical model was automatically updated. The use of state-space estimation allowed the computation of smooth derivatives of the orientation data. Owing to the non-linearity of the functions involved, the derivatives of the observation model were obtained through a multidimensional extension of Stirling's interpolation formula. Proper algorithms were developed to cope with the model calibration, initialisation and data labelling. Extensive experiments on real and simulated motions proved the reliability (maximum angular error less than 1 degree, maximum point reconstruction less than 1 mm) of the developed system, which is robust to false matching caused by marker occlusions. Moreover, orientation artifacts due to skin motion can be reduced by a factor of 50%.

Algorithms↗

Optimised procedure for the calibration of the force platform location.

An innovative optimised method, including an experiment and a mathematical model, for the calibration of the force platform location in the optoelectronic reference frame is proposed. The calibration experiment adopts a bearing-marker testing object contacting the platform and does not directly measure the platform location. The experiment is designed in order to avoid the main drawbacks possibly occurring in commonly adopted methods. The mathematical model of the experiment estimates the expected ground reaction. An optimisation algorithm identifies the optimal platform location as the one that best matches the measured outcome of the calibration experiment with the corresponding model estimate. The innovative calibration procedure has been assessed in terms of inter-tester reliability and compared with commonly used calibration procedures of platform location. These results evidenced how the introduction of such optimised procedure could improve the reliability of the calibrated platform location and, consequently, of the kinetic variables considered in posture and gait analysis.

Algorithms↗

Touch-screen system for assessing visuo-motor exploratory skills in neuropsychological disorders of spatial cognition.

A new computerised test adopting touch-screen technology has been developed to assess the visuo-motor exploration of extra-personal space. The test was derived from well-known paper-and-pencil cancellation tasks used widely in the diagnosis and quantitative assessment of unilateral spatial neglect (USN), a neuropsychological syndrome that is more frequent and severe after damage to the right cerebral hemisphere. A main component deficit of USN is the defective visuo-motor exploration of the side of space contralateral to the side of the lesion (contralesional), namely, in right-sided brain-damaged patients it occurs on the left side and vice versa. The computer-based paradigm consisted of a visuo-motor spatial exploratory task: the subjects were instructed to touch, in any order they wished, all the targets they detected on a computer touch-screen. This measured the time of occurrence and the spatial co-ordinates of each touch event and forwarded the data to the computer for storage; the computer provided feedback to the subject by 'tagging' the touched target. The paradigm allowed the calculation of accuracy and latency indexes and recorded the exploratory pathway taken by each subject. A pilot study was performed in ten normal subjects and 15 brain-damaged patients, with and without psychometric evidence of USN; the results showed that the equipment was able to provide quantitative indexes related to the spatial-temporal aspects of exploratory ability, which are useful for diagnostic purposes, and revealed significant differences between the controls and patients with USN: the overall average values of latency and crossing indexes increased in patients with USN, compared with the controls (latency from 0.77 to 1.90s; path crossing index from 7.0% to 59.5%), and the significantly negative USN patient latency gradient (-2.79 against a null control value) evidenced a worsening of performance towards the left side.

Aged↗

Self-marking of anatomical landmarks for on-orbit experimental motion analysis compared to expert direct-marking.

The on-orbit application of movement analysis methodology, on-board space stations, for studying the gravity role in motor functions, requires a careful adaptation of the currently adopted techniques in order to obtain reliable data. In those operative conditions, differently from common on-ground experimental activities, a non-specialist operator, an astronaut of the space station crew, is expected to self-administer the experimental protocol, particularly self-marking specific anatomical landmarks. The present paper proposes a movement analysis methodology, which fits the specific constraints of space activity and matches the objective of maximising reliability and minimising on-orbit time, and reports normative data about accuracy and precision of the self-marking of an extended set of anatomical landmarks. The same set of landmarks has been considered also for direct-marking performed by experts in motion analysis and their results have been compared to self-marking ones. The paper contents will support the design of future space experimental campaigns and is, in general, applicable to any on-ground scientific investigation, possibly increasing data reliability.

Adult↗

Spot check of the calibrated force platform location.

In a movement analysis laboratory, stereophotogrammetric motion capture systems and force platforms must share one absolute reference frame that allows the computation of joint moments and powers. The correct calibration of the platform location identifies the transformation between force plate and absolute reference systems, which determines the spatial coherence among the equipments' measurements. The aim of this study was to develop and test a spot check for the assessment of platform location calibration. Platform location calibration was assessed by comparing the measured outcome of an experiment performed with a pointed rigid rod bearing a set of markers with the corresponding expected results, computed with a model. A set of indices was then proposed to define a confidence volume in which the true ground reaction force is expected to be. The spot check was applied to a real laboratory setup and the effects of simulated platform mislocations were analysed. It was verified that the hip joint moment may be equally affected by a single marker misplacement of about 20mm during platform location calibration, an occurrence that was clearly identified by the spot check, and by a hip centre location inaccuracy of 30mm.

Biomechanical Phenomena↗

Ground reaction: intrinsic and extrinsic variability assessment and related method for artefact treatment.

Ground reaction (GR) components measured by a dynamometric platform represent the dynamic interaction of the moving human body with the ground and depend on the subject-platform relative position and orientation. The observed variability among the GR measurements of the walking trials of an individual is either due to variability in the motor performance (intrinsic variability) or due to changes in the direction of walking and in the position and orientation of the striking foot relative to the platform (extrinsic variability). A method, based on the median operator, is presented here which lets us quantify the two components of variability. The application of the method to a large data set of normal subjects evidenced changes in progression direction/foot orientation (95th percentile value is 6.9 degrees ), which can dramatically change the patterns of GR components. This result warns about improper analysis of ground reaction measurement. An algorithm for restoring GR measurements affected by artefact was derived from the above method. This tool can be of valuable aid in clinical practice where patients' conditions suggest to not insist on repetition of trials even if the required number of correct foot placements has not been achieved. The artefact correction algorithm has been applied to a large data set artificially corrupted to evaluate its robustness.

Adult↗

Production of leukotrienes in a model of focal cerebral ischaemia in the rat.

1. The aim of this work was to evaluate the role of leukotrienes in brain damage in vivo in a model of focal cerebral ischaemia in the rat, obtained by permanent occlusion of middle cerebral artery. 2. A significant (P < 0.01) elevation of LTC(4), LTD(4) and LTE(4) (cysteinyl-leukotrienes) levels occurred 4 h after ischaemia induction in the ipsilateral cortices of ischaemic compared to sham-operated animals (3998 +/- 475 and 897 +/- 170 fmol g(-1) tissue, respectively, P < 0.01). 3. The NMDA receptor antagonist MK-801 and the adenosine A(2A) receptor antagonist SCH 58261 were administered in vivo at doses known to reduce infarct size and compared with the leukotriene biosynthesis inhibitor MK-886. 4. MK-886 (0.3 and 2 mg kg(-1) i.v.) and MK-801 (3 mg kg(-1) i.p.) decreased cysteinyl-leukotriene levels (-78%, P < 0.05; -100%, P < 0.01; -92%, P < 0.01, respectively) 4 h after permanent occlusion of the middle cerebral artery, whereas SCH 58261 (0.01 mg kg(-1) i.v.) had no significant effects. 5. MK-886 (2 mg kg(-1) i.v.) was also able to significantly reduce the cortical infarct size by 30% (P < 0.05). 6. We conclude that cysteinyl-leukotriene formation is associated with NMDA receptor activation, and that it represents a neurotoxic event, the inhibition of which is able to reduce brain infarct area in a focal ischaemic event.

Animals↗

Inhibition of caspase-1-like activity by Ac-Tyr-Val-Ala-Asp-chloromethyl ketone induces long-lasting neuroprotection in cerebral ischemia through apoptosis reduction and decrease of proinflammatory cytokines.

Broad spectrum caspase inhibitors have been found to reduce neurodegeneration caused by cerebral ischemia. We studied whether blockade of group I caspases, mainly caspase-1, using the inhibitor Ac-YVAD.cmk reduced infarct volume and produced prolonged neuroprotection. Ac-YVAD.cmk (300 ng/rat) was injected intracerebroventricularly 10 min after permanent middle cerebral artery occlusion in the rat. Drug treatment induced a significant reduction of infarct volume not only 24 hr after ischemia (total damage, percentage of hemisphere volume: control, 41.1 +/- 2.3%; treated, 26.5 +/- 2.1%; p < 0.05) but also 6 d later (total damage: control, 30.6 +/- 2.2%; treated, 23.0 +/- 2.2%; p < 0.05). Ac-YVAD. cmk treatment resulted in a reduction not only of caspase-1 (control, 100 +/- 20.3%; treated, 3.4 +/- 10.4%; p < 0.01) but also of caspase-3 (control, 100 +/- 30.3%; treated, 13.2 +/- 9.5%; p < 0.05) activity at 24 hr and led to a parallel decrease of apoptosis as measured by nucleosome quantitation (control, 100 +/- 11.8%; treated, 47 +/- 5.9%; p < 0.05). Six days after treatment no differences in these parameters could be detected between control and treated animals. Likewise, brain levels of the proinflammatory cytokines IL-1beta and TNF-alpha were reduced at 24 hr (39.5 +/- 23.7 and 51.9 +/- 10.3% of control, respectively) but not at 6 d. Other cytokines, IL-10, MCP-1, MIP-2, and the gaseous mediator nitric oxide, were not modified by the treatment. These findings indicate that blockade of caspase-1-like activity induces a long-lasting neuroprotective effect that, in our experimental conditions, takes place in the early stages of damage progression. Finally, this effect is achieved by interfering with both apoptotic and inflammatory mechanisms.

Amino Acid Chloromethyl Ketones↗

Instrumented staircase for ground reaction measurement.

A staircase was developed to record ground reactions during stair climbing at different slopes (inclinations). Each step is instrumented with six strain-gauge-based force transducers which allow the measurement of three-dimensional ground reaction force and moment as well as the centre of pressure (COP) location. A specific sensor arrangement permits accurate recording, especially of the COP location. The overall design of the staircase and details of a single instrumented step are presented. Static and dynamic characteristics have been evaluated by different experimental procedures. Preliminary results of ground reaction forces are shown.

Biomechanical Phenomena↗

Are perception and action affected differently by the Titchener circles illusion?

In the present study, we investigated the effects of the Titchener circles illusion in perception and action. In this illusion, two identical discs can be perceived as being different in size when one is surrounded by an annulus of smaller circles and the other is surrounded by an annulus of larger circles. This classic size-contrast illusion, known as Ebbinghaus or Titchener Circles Illusion, has a strong perceptual effect. By contrast, it has recently been demonstrated that when subjects are required to pick up one of the discs, their grip aperture during reaching is largely appropriate to the size of the target. This result has been considered as evidence of a clear dissociation between visual perception and visuomotor behaviour in the intact human brain. In this study, we suggest and investigate an alternative explanation for these results. We argue that, in a previous study, while perception was subjected to the simultaneous influence of the large and small circles displays, in the grasping task only the annulus of circles surrounding the target object was influential. We tested this hypothesis by requiring 18 subjects to perceptually estimate and grasp a disc centred in a single annulus of Titchener circles. The results showed that both the perceptual estimation and the hand shaping while grasping the disc were similarly influenced by the illusion. Moreover, the stronger the perceptual illusion, the greater the effect on the grip scaling. We discuss the results as evidence of an interaction between the functional pathways for perception and action in the intact human brain.

Adult↗

Long-term adaptation of postural control in microgravity.

Orbital microgravity represents a unique environment, which allows the isolation of variables assumed to be involved in the mechanism of body positioning in space. In this context, the alignment of the trunk axis along allocentric references and the positioning of the body center of mass inside the supporting base compete for the role of the primary-controlled variable when assuming erect posture. This paper reports the quantitative evaluation of the postural strategies exhibited by two subjects with feet fixed to the floor of the space module along a 4-month period of exposure to microgravity. With respect to previous findings in parabolic flights and short term space missions, the analysis focused on long-term process of sensorimotor adaptation to weightlessness. Results show that while trunk-axis orientation is preserved and used as a stable postural frame of reference, the positioning of the body center of mass appears to be significantly biased backward and turns out to be involved in a long-term process of adaptation throughout the entire flight towards the re-emergence of a typically terrestrial postural regulation compatible with equilibrium.

Adult↗

Kinematic characteristics of standing disequilibrium: reliability and validity of a posturographic protocol.

OBJECTIVE: To investigate retest reliability and concurrent validity of the fundamental measurements made of a posturographic protocol that employs quiet standing to quantify the severity and the nature of patients' postural disturbances. STUDY DESIGN: Retrospective complete block design. SETTING: Geriatric rehabilitation department. PARTICIPANTS: Thirty-six participants (age range, 67 to 86 yrs) having normal, moderate, or severe levels of disequilibrium. METHODS: Quiet standing was evaluated on three occasions using a three-dimensional motion analysis system and a force platform. Eight testing conditions, designed to vary task difficulty by controlling the contributions of vision, foot proprioception, and base-of-support width, were administered. MAIN OUTCOME MEASURES: Retest reliability of body sway, joint alignment, body position, and motor coordination indicators were evaluated by intraclass correlation coefficients (ICCs). Concurrent validity of protocol measures was evaluated by the prediction of disequilibrium from a stepwise linear discriminant analysis. RESULTS: ICCs indicated high level of retest reliability for all variables but those of motor coordination, which was not influenced by testing conditions. Discriminant analysis resulted in a four-factor discriminator that included measures of body sway, position, alignment, and motor coordination. The derived linear discriminate function correctly classified 96% of the patients' level of disequilibrium. CONCLUSIONS: The posturographic protocol has the potential to be a useful tool for evaluating severity and nature of postural instability and the effects of pharmacologic and rehabilitative treatment. Results also indicate that combining direct body measurements with force-plate data has the potential to expose the underlying impairments that cause disequilibrium, determine their pathogenesis, and evaluate compensatory strategies.

Aged↗

Validation protocol of models for centre of mass estimation.

The estimation of the body centre-of-mass (COM) position requires the modelling of the human body as a system of rigid segments and the measurement of the position of related external anatomical landmarks. Many models for COM position estimation have been proposed with different levels of complexity and, in some cases, specific protocols have been used for model accuracy evaluation. In this paper, we propose a general method for the quantitative assessment of any COM model in relation to a determined set of movements. It consists of an experimental protocol and of a set of comparative indices, which quantify the congruence among the estimated kinematic variables and their expected values. The general applicability of the method is specifically addressed to models' comparison, aiming to support the user in the process of choice and validation of the most suitable model for her/his purposes. In this frame, the results of the analytical comparison among two kinematic models with different levels of complexity are reported.

Algorithms↗

Multifactorial estimation of hip and knee joint centres for clinical application of gait analysis.

Estimation of joint centres is required in gait analysis for kinematic and kinetic elaboration. In general, the method is based on regression equations and palpation of bone prominences. A kinematic approach can also be used at the hip joint but appears to be more demanding for the patients. The method presented here combines different independent approaches and is aimed at reducing the estimation errors caused by from skin motion artefacts and statistical variance of anthropometric data. It is based on minimising an optimisation function in which data from gait kinematics, anthropometric measurements and statistically derived morphological parameters are properly weighted. The procedure is suitable for clinical applications where the range of motion might be reduced and the patients can not perform complicated exercises. Validation has been made on ten normal subjects and ten patients with spina bifida. The results show that the reproducibility of the estimation and the congruency with the external measurements is improved with respect to both the morphologically based approach and the kinematic method. Copyright 1998 Elsevier Science B.V.

Journal Article↗

Functionally oriented and clinically feasible quantitative gait analysis method.

A protocol for clinical gait analysis is described, and data from 30 normal adult female subjects are presented. Extensive application to pathologic subjects has proven to be feasible and sufficiently accurate. The method is based on a particular location and attachment of retro-reflective markers on the body and on a particular arrangement of four TV cameras. A motion analyser measures the 3D coordinates of each marker. A modelling approach, based on individual anthropometric measurements, and a functional approach, based on kinematical considerations, are used to estimate the location of hip, knee, and ankle joint centers and the orientation of the flexion-extension axis of the knee. 3D relative and absolute movements of pelvis and lower limbs are obtained and shown to be consistent with functional anatomy.

Adult↗

Transient expression of the 5alpha-reductase type 2 isozyme in the rat brain in late fetal and early postnatal life.

The enzyme 5alpha-reductase plays a key role on several brain functions controlling the formation of anxiolytic/anesthetic steroids derived from progesterone and deoxycorticosterone, the conversion of testosterone to dihydrotestosterone, and the removal of excess of potentially neurotoxic steroids. Two 5alpha-reductase isoforms have been cloned: 5alpha-reductase type 1 is widely distributed in the body, and 5alpha-reductase type 2 is confined to androgen-dependent structures. In this study, the gene expression of the two 5alpha-reductase isozymes has been analyzed in fetal, postnatal, and adult rat brains by RT-PCR followed by Southern analysis. 5Alpha-reductase type 1 messenger RNA is always detectable in the rat brain [from gestational day 14 (GD14) to adulthood]. 5Alpha-reductase type 2 messenger RNA expression is undetectable on GD14, increases after GD18, peaks on postnatal day 2, then decreases gradually, becoming low in adulthood. This pattern of expression appears to be correlated with the rate of production of testosterone by the testis. The possible control by androgens of gene expression of the two isozymes has been studied in brain tissues of animals exposed in utero to the androgen antagonist flutamide; the sex of the animals was determined by genetic sex screening of the SRY gene located on the Y-chromosome. In the brain of male embryos, flutamide treatment inhibited the expression of 5alpha-reductase type 2; this effect was much less pronounced in females. Moreover, 5alpha-reductase type 2 gene expression in cultured hypothalamic neurons is highly induced by testosterone and by the phorbol ester 12-O-tetradecanoyl-phorbol-13 acetate. The transient, androgen-regulated, expression of 5alpha-reductase type 2 overlaps the critical period of development, which may be important for sexual differentiation of the brain and for the formation of anxiolytic/anesthetic steroids involved in the stress responses associated with parturition.

3-Oxo-5-alpha-Steroid 4-Dehydrogenase↗

Identification of type 1 5alpha-reductase in myelin membranes of male and female rat brain.

The formation of the 5alpha-reduced metabolites of testosterone (T) and of progesterone (P) is a very active process in the brain, since the enzyme 5alpha-reductase (5alpha-R) is present in almost any central nervous system (CNS) structure. A particularly elevated 5alpha-R activity has been shown in myelin sheaths. Two isoforms of the enzyme have been cloned, with different localisation as well as different biochemical properties. The present study was performed to determine whether both isoforms of the 5alpha-R, or only one of them, are/is responsible for the enzymatic activity observed in myelin. Kinetic analyses have been performed on purified myelin membranes prepared from the male or female rat brain, using both T and P as substrates. The 5alpha-R present appears to possess a pH optimum at basic values. The Vmax values obtained in the Lineweaver-Burk analysis were comparable in male and female preparations independently on whether T or P were used as the substrates, suggesting that a single enzymatic form is present in all samples examined; the Km obtained using [14C]T (Km: male 1.14 microM; female 1.46 microM) or [14C]P (Km: male 0.5 microM; female 0.64 microM) as substrates, were in good agreement with those obtained for the recombinant type 1 isoform. These data suggest that the type 1 isoform is the most relevant 5alpha-R present in myelin. To confirm this, a new polyclonal antibody was raised against the type 1 5alpha-R enzymatic protein, and used in immunohistochemical studies. The experiments were performed on the optic nerve, a myelinated structure very rich in 5alpha-R activity and the results clearly indicated the presence of a specific type 1 enzyme immunoreactivity in the myelin sheaths of axons.

3-Oxo-5-alpha-Steroid 4-Dehydrogenase↗