PubMed Health⌕ Search

Biomedical subjects

M Rawhouser

Publications and source records attributed to M Rawhouser.

2 recordsLinked to original sources

Recent improvements in a completely implanted total artificial heart.

The total artificial heart under development by the Pennsylvania State University and 3M Health Care has undergone a number of design improvements to improve reliability, manufacturability, implantability, and performance. These improvements are nearing completion in preparation for formal durability testing. The redesigned implanted electronics canister, consisting of a welded titanium shell with hermetic connectors, contains the control, telemetry, and energy transmission electronics, as well as a 9 cell, 800 mAhr Ni-Cd battery pack. Functional changes include a reduction in the battery recharge time from 14 hours to 4 hours, and a new inductive telemetry system. The energy transmission system operating frequency has been increased from 160 kHz to 200 kHz. Electromagnetic interference filters and a more efficient control mode have also been implemented. The energy converter has been modified to incorporate a new motor with integral Hall effect position sensors, and new cable, and compliance chamber conduit fittings. High flex life cable is now used for the motor and coil cables. Two prototype durability mock circulatory loops have been built and are being tested. Substantial progress has been made in the completion of manufacturing documentation, and in the implementation of a quality system.

Animals↗

Postoperative pulmonary complications in calves after implantation of an electric total artificial heart.

In long-term studies testing the Penn State Total Artificial Heart involving 30 calves, seven calves died of pulmonary complications within 2 weeks after receiving the implant (Group 1 [G1]) and seven calves survived from 2 weeks to 3 months without infection (Group 2 [G2]). Comparative studies were performed using multiple variables: cardiopulmonary bypass (CPB) time, cardiac index, central venous pressure, leukocyte count, hematocrit, total protein, albumin, serum glutamic oxaloacetic transaminase (GOT), creatinine, water balance, and transfused blood volume. In G1, CPB time was longer than in G2 (182 +/- 19 vs 156 +/- 17 minutes, respectively, p = 0.018). Postoperative minimum total protein and albumin in G1 were lower than those in G2 (56.5% +/- 6.0% and 59.0% +/- 5.5% of preoperative values vs 68.4% +/- 8.5% and 67.8% +/- 6.1%, respectively, p = 0.011 and 0.015). Water balance in G2 was more positive than in G1 (11.7 +/- 6.8 vs 1.4 +/- 8.3 L, respectively, p = 0.020). Other variables showed no significant differences. Microscopic findings of the lung in G1 were congestion, hemorrhage, aggregation of neutrophils, and proteinaceous material within the interstitial tissues and alveoli.

Animals↗