PubMed Health⌕ Search

Biomedical subjects

M Reiser

Publications and source records attributed to M Reiser.

At least 55 records · Page 3Linked to original sources

[Sub-specialization within the field of radiology].

Medical knowledge and skills are accumulating at an ever increasing speed. Therefore, it becomes more and more difficult for a single one to have a complete overview of a whole discipline. This general observation also applies for radiology. Radiology has to cooperate with almost all medical disciplines and has to provide competent experts. It is therefore mandatory to support differentiation within the field of radiology and at the same time to save coherence and future developments.

Germany↗

[DRG and OPS-301: effects on the acquisition performance in radiology].

Reimbursement for inpatient services rendered based on comparable daily care rates, case-based flat rates, and special fees as practiced until now has been replaced by the system of diagnosis-related groups. Up until 2004, operation and procedure system (OPS 301) codes could be processed completely automatically by appropriate adaptation of the radiology information system (RIS). Because of further differentiation of OPS codes in the 2005 version, it is no longer possible to unambiguously determine OPS codes automatically. Our goal was to fulfill these additional requirements with as little extra effort as possible. In 36 of 2138 procedures during an observation period of 12 days, i.e., 4/day, manual input on the part of the radiology technical assistant and quality assurance by the diagnosing physician were necessary. This is only needed in complicated procedures for which the minor added effort is negligible in comparison to the entire effort expended for the procedure. We were thus able to achieve the goal of near automation of ascertaining OPS codes.

Databases, Factual↗

[PACS: storage and retrieval of digital radiological image data].

BACKGROUND: Efficient handling of both picture archiving and retrieval is a crucial factor when new PACS installations as well as technical upgrades are planned. MATERIALS AND METHODS: For a large PACS installation for 200 actual studies, the number, modality,and body region of available priors were evaluated. In addition, image access time of 100 CT studies from hard disk (RAID), magneto-optic disk (MOD), and tape archives (TAPE) were accessed. RESULTS: For current examinations priors existed in 61.1% with an averaged quantity of 7.7 studies. Thereof 56.3% were within 0-3 months, 84.9% within 12 months, 91.7% within 24 months, and 96.2% within 36 months. On average, access to images from the hard disk cache was more than 100 times faster then from MOD or TAPE. CONCLUSION: Since only PACS RAID provides online image access, at least current imaging of the past 12 months should be available from cache. An accurate prefetching mechanism facilitates effective use of the expensive online cache area. For that, however, close interaction of PACS, RIS, and KIS is an indispensable prerequisite.

Database Management Systems↗

[Possibilities for workflow optimization in radiology departments beyond RIS and PACS].

Technological progress and the rising cost pressure on the healthcare system have led to a drastic change in the work environment of radiologists today. The pervasive demand for workflow optimization and increased efficiency of its activities raises the question of whether by employment of electronic systems, such as RIS and PACS, the potentials of digital technology are sufficiently used to fulfil this demand. This report describes the tasks and structures in radiology departments, which so far are only insufficiently supported by commercially available electronic systems but are nevertheless substantial. We developed and employed a web-based, integrated workplace system, which simplifies many daily tasks of departmental organization and administration apart from well-established tasks of documentation. Furthermore, we analyzed the effects exerted on departmental workflow by employment of this system for 3 years.

Database Management Systems↗

[Digital teaching archive. Concept, implementation, and experiences in a university setting].

Film-based teaching files require a substantial investment in human, logistic, and financial resources. The combination of computer and network technology facilitates the workflow integration of distributing radiologic teaching cases within an institution (intranet) or via the World Wide Web (Internet). A digital teaching file (DTF) should include the following basic functions: image import from different sources and of different formats, editing of imported images, uniform case classification, quality control (peer review), a controlled access of different user groups (in-house and external), and an efficient retrieval strategy. The portable network graphics image format (PNG) is especially suitable for DTFs because of several features: pixel support, 2D-interlacing, gamma correction, and lossless compression. The American College of Radiology (ACR) "Index for Radiological Diagnoses" is hierarchically organized and thus an ideal classification system for a DTF. Computer-based training (CBT) in radiology is described in numerous publications, from supplementing traditional learning methods to certified education via the Internet. Attractiveness of a CBT application can be increased by integration of graphical and interactive elements but makes workflow integration of daily case input more difficult. Our DTF was built with established Internet instruments and integrated into a heterogeneous PACS/RIS environment. It facilitates a quick transfer (DICOM_Send) of selected images at the time of interpretation to the DTF and access to the DTF application at any time anywhere within the university hospital intranet employing a standard web browser. A DTF is a small but important building block in an institutional strategy of knowledge management.

Computer-Assisted Instruction↗

[Speech recognition: impact on workflow and report availability].

With ongoing technical refinements speech recognition systems (SRS) are becoming an increasingly attractive alternative to traditional methods of preparing and transcribing medical reports. The two main components of any SRS are the acoustic model and the language model. Features of modern SRS with continuous speech recognition are macros with individually definable texts and report templates as well as the option to navigate in a text or to control SRS or RIS functions by speech recognition. The best benefit from SRS can be obtained if it is integrated into a RIS/RIS-PACS installation. Report availability and time efficiency of the reporting process (related to recognition rate, time expenditure for editing and correcting a report) are the principal determinants of the clinical performance of any SRS. For practical purposes the recognition rate is estimated by the error rate (unit "word"). Error rates range from 4 to 28%. Roughly 20% of them are errors in the vocabulary which may result in clinically relevant misinterpretation. It is thus mandatory to thoroughly correct any transcribed text as well as to continuously train and adapt the SRS vocabulary. The implementation of SRS dramatically improves report availability. This is most pronounced for CT and CR. However, the individual time expenditure for (SRS-based) reporting increased by 20-25% (CR) and according to literature data there is an increase by 30% for CT and MRI. The extent to which the transcription staff profits from SRS depends largely on its qualification. Online dictation implies a workload shift from the transcription staff to the reporting radiologist.

Database Management Systems↗

[MR imaging in congenital disorders of the brain].

MR imaging is an excellent tool for use in diagnosing congenital malformations of the brain. Such malformations cannot be reliably recognized or classified without an insight in to the basic processes of the fetal development of the brain. Cortical malformations are classically divided into (1) malformations of neuronal proliferation, i.e. of stem cell proliferation in the periventricular germinal matrix zone, (2) disorders of neuronal migration, i.e. of the radial migration of the neurons from the periventricular germinal matrix zone to the cortical surface, and (3) disorders of cortical organisation. Other cerebral malformations are agenesis or dysgenesis of the corpus callosum, encephaloceles and various kinds of holoprosencephaly. Chiari malformations and disorders on the Dandy-Walker spectrum are relatively common, primarily infratentorial disorders. Rarer infratentorial disorders are Joubert syndrome, rhombencephalosynapsis and Lhermitte Duclos syndrome.

Adolescent↗

[Radiological intervention in multiply injured patients].

The most frequent cause of mortality during the first 4 h following severe trauma is uncontrollable hemorrhage from large arteries and parenchymal organs, whereas traumatic injuries of the heart and aorta are responsible for sudden death occurring at the accident site. It is therefore mandatory to diagnose and treat these injuries rapidly. Multislice spiral computed tomography is a highly useful imaging modality for severely injured patients. In this group of patients, various interventional procedures such as embolisation, stenting and temporary balloon occlusion may contribute to saving lives. In ruptures of the aorta and major arteries, stenting and temporary balloon occlusion may prevent exsanguination. Transcatheter embolisation is useful in hemorrhage from visceral organs, arteriovenous fistulas and secondary onset hemorrhage.

Algorithms↗

Image guided interstitial laser thermotherapy: a canine model evaluated by magnetic resonance imaging and quantitative autoradiography.

OBJECTIVE: To determine the applicability and safety of a new canine model suitable for correlative magnetic resonance imaging (MRI) studies and morphological/pathophysiological examination over time after interstitial laser thermotherapy (ILTT) in brain tissue. MATERIAL AND METHODS: A laser fibre (Diode Laser 830 nm) with an integrated temperature feedback system was inserted into the right frontal white matter in 18 dogs using frameless navigation technique. MRI thermometry (phase mapping i.e. chemical shift of the proton resonance frequency) during interstitial heating was compared to simultaneously recorded interstitial fiberoptic temperature readings on the border of the lesion. To study brain capillary function in response to ILTT over time quantitative autoradiography was performed investigating the unidirectional blood-to-tissue transport of carbon-14-labelled alpha amino-isobutyric acid (transfer constant K of AIB) 12, 36 hours, 7, 14 days, 4 weeks and 3 months after ILTT. RESULTS: All laser procedures were well tolerated, laser and temperature fibres could be adequately placed in the right frontal lobe in all animals. In 5 animals MRI-based temperature quantification correlated strongly to invasive temperature measurements. In the remaining animals the temperature fibre was located in the area of susceptibility artifacts, therefore, no temperature correlation was possible. The laser lesions consisted of a central area of calcified necrosis which was surrounded by an area of reactive brain tissue with increased permeability. Quantitative autoradiography indicated a thin and spherical blood brain barrier lesion. The magnitude of K of AIB increased from 12 hours to 14 days after ILTT and decreased thereafter. The mean value of K of AIB was 19 times (2 times) that of normal white matter (cortex), respectively. CONCLUSION: ILTT causes transient, highly localised areas of increased capillary permeability surrounding the laser lesion. Phase contrast imaging for MRI thermomonitoring can currently not be used for reliable temperature readings in vivo. The suggested new canine model proved to be safe, accurate, easy to use, and provides clinical, radiographic, pathological and physiological correlations.

Aminoisobutyric Acids↗

[Visualization and quantification of large bowel motility with functional cine-MRI].

PURPOSE: To develop and evaluate a method to visualize and quantify large bowel motility using functional cine MRI. METHODS: Fifteen healthy individuals (8 males, 7 females, 20 to 45 years old) with no history or present symptoms of bowel disorders were enrolled in a functional cine MRI examination at 6 a. m. after a starving phase for at least eight hours before and after oral administration of Senna tea (mild stimulating purgative). Two consecutive sets of repeated measurements of the entire abdomen were performed using a 1.5 T MRI system with coronal T2-weighted HASTE sequences anatomically adjusted to the course of the large bowel. A navigator technique was used for respiratory gating at the level of the right dorsal diaphragm. The changes in diameter (given in cm) were measured at 5 different locations of the ascending (AC), transverse (TC) and descending colon (DC), and assessed as parameters for the bowel motility. RESULTS: The mean values as a statistical measure for large bowel relaxation were determined. Before ingestion of Senna tea, the mean diameter measured 3.41 cm (ascending colon), 3 cm (transverse colon) and 2.67 cm (descending colon). After the ingestion of Senna tea, the mean diameter increased to 3.69 cm (ascending colon) to 3.4 cm (transverse colon) and to 2.9 cm (descending colon). A statistically significant difference was demonstrated with the Wilcoxon test (level of confidence 0.05). For the determination of dynamic increase, the changes of the statistical scatter amplitude to the mean value were expressed as percentage before and after the ingestion of Senna tea. Thereby, an increase in variation and dynamic range was detected for the AC (112.9 %) and DC (100 %), but a decrease in the dynamics for the TC (69 %). CONCLUSION: A non-invasive method for the assessment of bowel motility was developed for the first time. The use of functional cine MRI utilizing a prokinetic stimulus allowed visualisation and quantification of large bowel motility. Further studies have to determine whether this technique is clinically relevant.

Adult↗

[Recommendations for the selection of storage media for archiving digital radiological image data based on the comparison of retrieval times at different PACS archive levels].

PURPOSE: Recommendations for archiving digital radiological image data based on the comparison of retrieval times for different PACS archive levels. MATERIALS AND METHODS: For a large PACS installation (Agfa Impax, Release 4.1), image retrieval times for radiological standard examinations (chest radiographs with 2, MRI with 250, CT with 100 and 1000 images; n = 120, each) from hard disk array, magneto-optical disk (MOD), and magnetic tape archives (TAPE) were examined in high and low network traffic load. RESULTS: Even large CT examinations (1000 images) were available from hard disk arrays within 4.0 +/- 0.8 s, smaller studies within 1.8 +/- 0.3 s. Radiographic image retrieval from MOD (30 +/- 4.7 s) was more then 50 % faster than from TAPE. For typical cross-sectional studies, the velocity gain amounted to 19 %. For both technologies, no significant difference was found for large CT examinations (651 +/- 144 s). For high and low network traffic load scenarios, image retrieval times from hard disk, MOD, and TAPE archives increased by 87 %, 7 %, and 22 %, respectively. CONCLUSION: Hard disk arrays are specifically suited as departmental intermediate storage media because they allow fast access to current and previous examinations within a short time. Performance properties enable both MOD and TAPE systems to serve as long-term archives. However, MOD archives are less flexible in the expansion of storage capacity and at present the medium costs per memory unit are about 2 - 3 times higher than for tape archives. The use of existing MOD-archives may be adequate as intermediate archives. For new PACS installations or system expansions, however, it is recommended to combine a sufficiently large local data memory (RAID) with data storage on tape archives outside the radiological unit that can be used by other departments as well. Future development of hard disk prices will show whether archiving for the whole data retention period may be handled by RAID systems. In any case, prefetching problems and waiting periods for demanded pre-studies would not occur any more.

Humans↗

[Role of osteoporosis in trauma diagnostics].

PURPOSE: To evaluate the current bone mineral density (BMD) distribution in elderly patients hospitalized due to traumatic hip fracture and to assess the necessity of concomitant pharmacotherapy of underlying osteoporosis. MATERIALS AND METHODS: 58 female patients > or = 50 years (mean 81 years) with proven hip fracture were included. The diagnosis of fracture was established either by conventional radiography (CR) or by computed tomography (CT). BMD was assessed prospectively by means of dual energy X-ray absorption (DXA) measurement of the lumbar spine and/or femoral neck. DXA data was routinely achieved by analysis of T- and Z-values of the BMD. Distribution of BMD was assessed. Results for both measurement sites were compared using T-test and Pearson correlation analysis. RESULTS: 56/58 patients with proven hip fracture received DXA of the lumbar spine, 51 DXA of the femoral neck. The mean BMD was 0.829 +/- 0.137 g/cm (2) (lumbar spine) and 0.451 +/- 0.126 g/cm (2) (femur). T-values were - 2.8 +/- 1.14 (lumbar spine) and - 3.53 +/- 0.97 (femur). Compared to the normal distribution (lumbar spine), 53 patients (94.6 %) had diminished BMD (T < or = - 1). Of these 15 (26.8 %) had osteopenia (T > - 2.5) and 38 (67.9 %) had osteoporosis (T < or = - 2.5) according to WHO definition. With respect to femoral bone measurement, all patients (100 %) had diminished BMD (T < or = - 1), 9 patients (17.6 %) had osteopenia (T > - 2.5) and 42 patients (82.4 %) had osteoporosis (T < or = - 2.5). Results for different measurement sites differed significantly and were weakly correlated. CONCLUSION: This data indicate that diminished BMD in terms of osteopenia or osteoporosis is a frequent finding in hip fractures of elderly females. A large majority of these elderly patients therefore should be treated according to recent guidelines for treatment of osteoporosis. Our data indicate that this entity is potentially underdiagnosed and should be considered by radiologists as well as traumatologists.

Absorptiometry, Photon↗

Initial clinical results with a new needle screen storage phosphor system in chest radiograms.

PURPOSE: To evaluate image quality and anatomical detail depiction in dose-reduced digital plain chest radiograms using a new needle screen storage phosphor (NIP) in comparison to full dose conventional powder screen storage phosphor (PIP) images. MATERIALS AND METHODS: 24 supine chest radiograms were obtained with PIP at standard dose and compared to follow-up studies of the same patients obtained with NIP with dose reduced to 50 % of the PIP dose (all imaging systems: AGFA-Gevaert, Mortsel, Belgium). In both systems identical versions of post-processing software supplied by the manufacturer were used with matched parameters. Six independent readers blinded to both modality and dose evaluated the images for depiction and differentiation of defined anatomical regions (peripheral lung parenchyma, central lung parenchyma, hilum, heart, diaphragm, upper mediastinum, and bone). All NIP images were compared to the corresponding PIP images using a five-point scale (- 2, clearly inferior to + 2, clearly superior). Overall image quality was rated for each PIP and NIP image separately (1, not usable to 5, excellent). RESULTS: PIP and dose reduced NIP images were rated equivalent. Mean image noise impression was only slightly higher on NIP images. Mean image quality for NIP showed no significant differences (p > 0.05, Mann-Whitney U test). CONCLUSION: With the use of the new needle structured storage phosphors in chest radiography, dose reduction of up to 50 % is possible without detracting from image quality or detail depiction. Especially in patients with multiple follow-up studies the overall dose can be decreased significantly.

Adult↗

In vivo cartilage deformation after different types of activity and its dependence on physical training status.

BACKGROUND: Knowledge of the deformational behaviour of articular cartilage in vivo is required to understand the pathogenesis of osteoarthritis and the mechanical target environment of prospective cartilage transplant recipients. OBJECTIVES: To study the in vivo deformational behaviour of patellar and femorotibial cartilage for different types of physiological activities; and to test the hypothesis that in vivo deformation of cartilage is modified by intense physical exercise. METHODS: Magnetic resonance imaging and 3D digital image analysis were used to determine cartilage volume before and after physical activity in the patella of 12 volunteers (knee bends, squatting, normal gait, running, cycling). Deformation of femorotibial cartilage was investigated in 10 subjects (knee bends, static compression, high impact loading). Patellar cartilage deformation after knee bends was compared in seven professional weight lifters, seven sprinters, and 14 untrained volunteers. RESULTS: Patellar cartilage deformation was -5.9% after knee bends, -4.7% after squatting, -2.8% after normal walking, -5.0% after running, and -4.5% after cycling. The pattern of patellar cartilage deformation corresponded to the range of motion involved in the particular activity. Tibial cartilage deformation was greatest under high impact loading (-7%), but small for other activities. No significant difference was found between athletes and non-athletic controls. CONCLUSIONS: Patellar cartilage deformation shows a "dose dependent" response, where more intense loading leads to greater deformation. Relatively little deformation was observed in the femorotibial joint, except during high impact activities. The findings provide no evidence that adult human cartilage properties are amendable to training effects in vivo.

Adult↗

The University of Maryland electron ring: a platform for study of galactic dynamics on a laboratory scale.

The University of Maryland electron ring (UMER) is a novel experimental storage ring designed to investigate the dynamics of large systems of collisionless particles that nevertheless interact via collective mechanisms. Heavily diagnosed and designed to circulate a 100 mA electron beam at 10 keV for several turns, UMER allows us to follow the evolution of the beam over a large number of dynamical periods. Given the similarity of dynamics between the Coulomb forces and gravitational forces, it is possible to design beam experiments that will simulate such astrophysical events as galactic merger, for instance. The cross-comparison of beam experiments with accelerator simulation codes provides invaluable benchmarks of transient processes akin to, for example, violent relaxation in stellar systems that are otherwise impossible to obtain.

Journal Article↗

Transient benign osteopetrosis in a calf persistently infected with bovine virus diarrhoea virus.

A two-day-old Simmental calf was admitted suffering from a fracture of the right femur. The radiographs showed striking changes in all bones, evident as alter-noting zones of dense and less dense tissue (bone-in-bone) in the right femur and striped densities in the vertebral bodies. A stainless steel plate was used to repair the fracture, which healed well. The calf developed normally but was diagnosed as persistently infected with bovine virus diarrhoea (BVD) virus. It was kept in isolation and examined physically and radiographically during the following 13 months. The radiographic changes diminished during the first three months and at 13 months were barely visible. The animal was euthanatized, and immunohistochemistry revealed BVD virus antigen in numerous tissues. The radiographic abnormalities seen in this case are similar to those of the transient form of osteopetrosis in humans. Osteopetrosis in humans is currently thought to have a genetical cause, whereas it appears to be associated with viral disease in animals.

Animals↗

Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose.

The aim of the study was to implement an abdominal CT angiography protocol using 100 kVp and to compare SNR and CNR, as well as subjective image quality, to a standard CT angiography protocol using 120 kVp on a 16 detector-row CT scanner. Forty-eight patients were referred for routine abdominal CT angiography on a 16 detector-row CT scanner. Patients were scanned using either 120 or 100 kVp at constant mAs settings. Vessel opacification was provided by automated contrast injection using similar injection protocols. Density measurements were performed along the aorto-iliac axis with SNR and CNR calculation. In addition, the estimated effective patient radiation dose was calculated. Results of both protocols were compared. The 100-kVp protocol (432+/-80 HU) showed a significantly higher vessel density than the 120-kVp (333+/-90 HU; P<0.001) protocol, corresponding to an average increase in signal intensity of 30.7%. SNR (36.0 vs 37.0) and CNR (31.1 vs 31.7) for the 100-kV protocol were not significantly lower that those for the standard protocol (P=0.79 and P=0.87), whilst the average estimated dose was significantly lower using the 100-kVp protocol (6.7+/-0.4 vs 10.1+/-1.2 mSv; P<0.0001). Tube kVp reduction from 120 to 100 kVp allows for significant reduction of patient dose in abdominal CT angiography, without significant change in SNR,CNR and image quality.

Adult↗

IT services in a completely digitized radiological department: value and benefit of an in-house departmental IT group.

To analyze the benefit of a departmental IT group in comparison to support by hospital IT groups or system manufacturers in a completely digitized radiological department. The departmental IT group comprises a fulltime IT specialist, two student assistants and four clinical employees participating 1 day/week. For 18 months IT problems were quantified and specified according to urgency, responsibility and affected system by use of an intranet-based reporting system. For each IT service provider the performance and duration of problem solution was evaluated. In 18 months 3,234 IT problems emerged. 88.7% were solved by the departmental IT group. In 474 cases (14.7%) a solution within 2 h was required. The departmental IT group solved 35.8% within 30 min, system manufacturers needed 18 h 38 min in mean. The departmental IT group solved 90.2% of the problems within a time limit. System manufacturers met the limit in 60.1% with a mean duration of 7 days 21 h. In 6.7% of the cases, support by system manufacturers was indispensable. A considerable proportion of IT problems in completely digitized radiological departments can be solved by a departmental IT group, providing a fast and cost-efficient first-level IT support with effective prevention of major breaks in the workflow. In a small number of cases support by system manufacturers remains necessary.

Computer Communication Networks↗