PubMed HealthSearch

Biomedical subjects

M Rodahl

Publications and source records attributed to M Rodahl.

3 recordsLinked to original sources

Bone response to surface-modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thicknesses.

The bone formation around titanium implants with varied surface properties is investigated. Machined and electropolished samples with and without thick, anodically formed surface oxides were prepared, surface characterized and inserted in the cortical bone of rabbits (1, 3 and 6 weeks). Scanning electron microscopy, scanning Auger electron spectroscopy and atomic force microscopy revealed marked differences in oxide thickness, surface topography and roughness, but no significant differences in surface chemical composition, between the different groups of implants. Light microscopic morphology and morphometry showed that all implants were in contact with bone and had a large proportion of bone within the threads at 6 weeks. The smooth, electropolished implants, irrespective of anodic oxidation, were surrounded by less bone than the machined implants after 1 week. After 6 weeks the bone volume as well as the bone-implant contact were lower for the merely electropolished implants than for the other three groups. Our study shows that a high degree of bone contact and bone formation are achieved with titanium implants which are modified with respect to oxide thickness and surface topography. However, the result with the smooth (electropolished) implants indicates that a reduction of surface roughness, in the initial phase, decreases the rate of bone formation in rabbit cortical bone.

Animals

Titanium with different oxides: in vitro studies of protein adsorption and contact activation.

Adsorption of albumin (HSA) and fibrinogen (Fib) from human blood plasma onto titanium surfaces with varying oxide properties was studied with an enzyme-linked immunosorbent assay. The intrinsic activation of blood coagulation (contact activation) was studied in vitro using a kallikrein-sensitive substrate. The sample surfaces were characterized with Fourier transform Raman spectroscopy. Auger electron spectroscopy and atomic force microscopy. Low Fib and high HSA adsorption was observed for all titanium samples except for the radio frequency plasma-treated and water-incubated samples, which adsorbed significantly lower amounts of both. Oxide thickness and carbon contamination showed no influence on protein adsorption or contact activation. Smooth samples with a surface roughness (Rrms) < 1 nm showed some correlation between surface wettability and adsorption of Fib and HSA, whereas rough surfaces (Rrms > 5 nm) did not. To varying degrees, all titanium surfaces indicated activation of the intrinsic pathway of coagulation as determined by their kallikrein formation in plasma.

Adsorption

Bone response to surface modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology.

In a series of experimental studies, bone formation was analysed around systematically modified titanium implants. In the present study, machined, electropolished and anodically oxidized implants were prepared, surface characterized and inserted in the cortical bone of rabbits (7 wks and 12 wks). SEM, scanning Auger electron spectroscopy and atomic force microscopy revealed no differences in surface composition but marked differences in oxide thickness, surface topography and roughness. Light microscopic morphology and morphometry showed that all implants were in contact with bone, and had a large proportion of bone within the threads. The smooth, electropolished implants were surrounded by less bone than the machined implants with similar oxide thickness, (4-5 nm) and the anodically oxidized implants with thicker oxides (21 nm and 180 nm, respectively) after 7 wks. These studies show that a high degree of bone contact and bone formation can be achieved with titanium implants which are modified with respect to oxide thickness and surface topography. However, it appears that a reduction of surface roughness may influence the rate of bone formation in rabbit cortical bone.

Animals