On the albumin-dependence of measurements of free thyroxin. II. Patients with non-thyroidal illness.

We studied the relation between thyroxin-binding proteins and free thyroxin (FT4) measurements by five radioimmunoassays (RIA) and an FT4 index (FT4I) in patients with non-thyroidal illness (NTI). The one-step FT4 RIAs and the FT4I frequently failed to identify the true FT4 status (as determined by equilibrium dialysis) of NTI patients. In these patients, falsely low FT4 results with one-step RIAs and FT4I were associated with decreasing total T3 and T4 concentrations, which, furthermore, paralleled decreasing serum albumin concentrations. All NTI patients with "low T3, low T4 syndrome" had subnormal albumin concentration. The two-step RIAs and equilibrium dialysis showed normal FT4 concentrations in most patients with NTI. However, sera from a subset of NTI patients with "low T3 syndrome" gave above-normal FT4 results with these methods. From their predictably poor performance in the presence of a subnormal albumin concentration, we conclude that the one-step FT4 RIAs and FT4I are inappropriate for testing the thyrometabolic status of NTI patients.

Diagnostic Errors↗

A model for assessing interference.

Most studies of analytical interference indicate the magnitude but not the type of interference. We developed a model for interference that assesses the magnitude of the following types of interference: independent of analyte concentration, dependent on analyte concentration, and a combination of the two. The experimental design for the model is an orthogonally arranged matrix with progressively increasing concentrations of analyte and interfering agent. Multiple regression with these independent variables (concentration of analyte, concentration of interfering agent, and the product of the two) is used to determine the magnitude, direction, and significance of each type of interference. Applying the model to study interference by hemoglobin with determinations of creatinine, direct bilirubin, and total bilirubin showed that hemoglobin interferes with determination of creatinine independent of the analyte concentration, interferes with total bilirubin dependent on the analyte concentration, and interferes with direct bilirubin by a combination of these two.

Bilirubin↗

Comparison of automated and manual methods for urinalysis.

The authors compared results for accuracy and precision obtained by a semiautomated prototype International Remote Imaging Systems, Inc. (IRIS) urinalysis workstation (IUW) with those from quantitative manual urinalysis (QMU). Three technologists skilled in urinalysis each performed 172 urinalyses with both the IUW and QMU methods. The results show that the IUW method is likely to yield comparable counts for particulate analytes compared with the QMU, except for casts. The QMU reported significantly (P less than 0.001) more casts than the IUW method. This difference is related to at least a ninefold greater volume of untreated urine examined by the QMU method than the IUW method. The IUW method may provide a more accurate result than the QMU method at very low and high concentrations of particulate analytes. The result from 24 blind duplicate urines also analyzed by each of the three technologists with both methods showed comparable precision for particulate analytes between the two methods except for red blood cells; the QMU method had significantly (P less than 0.001) better precision for this analyte.

Automation↗

On the albumin dependence of measurements of free thyroxin. I. Technical performance of seven methods.

We evaluated three one-step (analog) and two two-step radioimmunoassay for free thyroxin (FT4), and a FT4 index calculated from the total T4 (TT4) and thyroxin-binding globulin (TBG) ratio for technical performance, for correlation with the reference FT4 method (equilibrium dialysis), and for dependence on TBG and albumin concentrations. The one-step methods (Amerlex, Coat-A-Count, and GammaCoat) showed greater precision than the two-step procedures (GammaCoat and Spiria). Results by the latter two techniques, however, correlated better with those by equilibrium dialysis than did those by the analog methods or by TT4/TBG. Only the GammaCoat two-step method had a slight but statistically significant (inverse) correlation with TBG concentration. All three analog methods and TT4/TBG showed a marked dependence on albumin concentration, whereas the Spiria technique showed only a slight dependence. Only equilibrium dialysis was independent of both the TBG and albumin concentration. Thus, despite their good precision, the analog (one-step) FT4 methods and the TT4/TBG approach cannot be expected to produce valid results when the concentration of albumin in serum is abnormally low or high.

Dialysis↗

Sonic fragility of the head-tail bond of bacteriophage P22.

The binding of tail parts to the head of phage P22 is normally irreversible, but after adsorption to host cells sonication releases many of the tail parts intact. This release is dependent on the power of sonication, but is independent of the length of sonication from 2 to 32 s. This phenomenon has been used to show that the upper limit of the number of P22 particles that can bind to a cell is no lower than 700.