Using simple mathematical functions to simulate pathological structures--input for digital mammography clinical trial.

In this study a set of structures has been simulated to represent a range of clinically relevant breast cancer mammographic lesions including solid tumours and microcalcifications. All structures have been created using simple random-based mathematical functions and have been inserted into a subset of digital mammography images at appropriate contrast levels into various regions of the breast, including dense fibroglandular and adipose tissue. These structures and their appearance in these clinical images were evaluated in terms of how realistic they looked. They will be used as the input to a large-scale clinical trial designed to examine the effect of significant dose reduction in digital mammography by comparing the detectability of such structures in images acquired at full and quarter automatic exposure control (AEC) dose level and in images with simulated noise levels in between.

Adipose Tissue↗

Can the average glandular dose in routine digital mammography screening be reduced? A pilot study using revised image quality criteria.

There is a need for tools that in a simple way can be used for the evaluation of image quality related to clinical requirements in mammography. The aim of this work was to adjust the present European image quality criteria to be relevant also for digital mammography images, and to use as simple and as few criteria as possible. A pilot evaluation of the new set of criteria was made with mammograms of 28 women from a General Electric Senographe 2000D full-field digital mammography system. One breast was exposed using the standard automatic exposure mode, the other using about half of that absorbed dose. Three experienced radiologists evaluated the images using visual grading analysis technique. The results indicate that the new quality criteria can be used for the evaluation of image quality related to clinical requirements in digital mammography in a simple way. The results also suggest that absorbed doses for the mammography system used may be substantially reduced.

Aged↗

Threshold pixel size for shape determination of microcalcifications in digital mammography: a pilot study.

The effect of pixel size on shape determination in screening digital mammography systems was studied using a shape identification task as the measured outcome. Ten microcalcifications on screen-films were digitised to a range of pixel sizes (2.5-200 microm) and extracted from computed radiography (CR) images (50 microm) acquired under equivalent imaging conditions. Fifteen observers attempted to identify the shape of each microcalcification at each pixel size. The results were collated to provide a fraction of correct responses vs. pixel size curve for each microcalcification. Averaging over all shapes, pixel values >100 microm lead to a significant decrease in shape determination ability (p < 0.01) for digitised screen-film. For CR images, half the shapes were not properly identified. Hence, although 20-100 microm was sufficient for microcalcification shape determination for digitised screen-film images, 50 microm was only borderline sufficient for the CR digital images.

Breast Diseases↗

Clinical evaluation of a new set of image quality criteria for mammography.

The European Commission (EC) quality criteria for screen-film mammography are used as a tool to assess image quality. A new set of criteria was developed and initially tested in a previous study. In the present study, these criteria are further evaluated using screen-film mammograms that have been digitised, manipulated to simulate different image quality levels and reprinted on film. Expert radiologists have evaluated these manipulated images using both the original (EC) and the new criteria. A comparison of three different simulated dose levels reveals that the new criteria yield a larger separation of image criteria scores than the old ones. These results indicate that the new set of image quality criteria has a higher discriminative power than the old set and thus seems to be more suitable for evaluation of image quality in mammography.