Gram-negative water bacteria in hemodialysis systems.

Gram-negative bacteria can multiply relatively fast in a variety of hospital associated fluids ranging from distilled, deionized, reverse osmosis, and softened water, which are normally considered devoid of nutrients, to intravenous solutions and fluids associated with hemodialysis. Excessive levels of these bacteria in the dialysate of artificial kidney machines can be responsible for pyrogenic reactions or sepsis or both.

Gram-Negative Aerobic Bacteria↗

Thermoradiation inactivation of naturally occurring bacterial spores in soil.

Samples of soil collected from the Kennedy Space Center near the spacecraft assembly facilities were found to contain microorganisms very resistant to conventional sterilzation techniques. The inactivation kinetics of the naturally occurring spores in soil were investigated by using dry heat and ionizing radiation, first separately and then simultaneously. Dry-heat inactivation kinetics of spores was determined at 105 and 125 C; radiation inactivation kinetics was determined for dose rates of 660 and 76 krads/h at 25 C. Simultaneous combinations of heat and radiation were then investigated at 105, 110, 115, 120, and 125 C, with a dose rate of 76 krads/h. Combined treatment was found to be highly synergistic, requiring greatly reduced radiation doses to accomplish sterilization of the population.

Cell Survival↗

Factors that influence microbial contamination of fluids associated with hemodialysis machines.

Studies were conducted on the microbiological quality of fluids associated with different types of dialysis systems located in six dialysis centers and 14 homes. Included were (i) single-pass systems employing either parallel flow (Kiil or Gambro) or capillary cartridge dialyzers and (ii) recirculating single-pass and batch recirculating systems using coil dialyzers. Microbiological assays were performed on the water used to prepare dialysis fluid, the concentrated dialysate, and either pre- and postdialyzer dialysate (single-pass systems) or the dialysate contained in storage reservoirs and recirculating cannisters (recirculating systems). The levels of microbial contamination consisting of gram-negative bacteria were directly related to the type of dialysis system, method of water treatment, distribution system, and in some instances, the type of dialyzer. Recirculating single-pass and batch recirculating systems consistently contained significantly higher levels of contamination than single-pass systems. These results were directly related to the design of recirculating systems which permits carbon- and nitrogen-containing waste products dialyzed from the patient to accumulate, be used as nutrients by microorganisms, and subsequently allow for 2- to 4-log increases in contamination levels during a dialysis treatment. In contrast, levels of contamination in single-pass machines were related more to the quality of the water used to prepare dialysis fluid and the adequacy of cleaning and disinfection procedures than to the design of the system.

Acinetobacter↗

Morphological, biochemical, and growth characteristics of pseudomonas cepacia from distilled water.

Studies were conducted on three strains of Pseudomonas cepacia isolated and maintained in distilled water and on a laboratory-subcultured strain transferred to distilled water. Optimum growth rates and maximum population yields of the four strains in distilled water were obtained at 37 C, although high population levels (10(6)-10(7)/ml) were reached and maintained over extended incubation periods at temperatures from 18 C to 42 C. Two strains were able to grow in distilled water at temperatures ranging from 12 C to 48 C and to survive 48 h and 21 days at 50 C and 10 C, respectively. Cells from distilled water cultures inoculated into Trypticase soy broth showed an immediate two- to three-log drop at upper and lower temperature limits; survivors were able to initiate logarithmic growth. Results obtained in morphological, biochemical, and antibiotic tests affirmed the strain differences noted in growth studies.

Aerobiosis↗

Bacillus sp. ATCC 27380: a spore with extreme resistance to dry heat.

An unusual mesophilic Bacillus sp. was isolated from heated soil, and a cleaned spore preparation showed extraordinary resistance to dry heat (D(125C) = 139 h) and relative sensitivity to moist heat (D(80C) = 61 min). Biochemical tests and morphology fit no described species.

Bacillus↗

Factors affecting comparative resistance of naturally occurring and subcultured Pseudomonas aeruginosa to disinfectants.

A strain of Pseudomonas aeruginosa was isolated in pure culture from the reservoir of a hospital mist therapy unit by an extinction-dilution technique; its natural distilled water environment was used as a growth and maintenance medium. After a single subculture on Trypticase soy agar, the strain showed a marked decrease in resistance to inactivation by acetic acid, glutaraldehyde, chlorine dioxide, and a quaternary ammonium compound when compared with naturally occurring cells grown in mist therapy unit water. The following factors were observed to affect the relative resistances of naturally occurring and subcultured cells of the P. aeruginosa strain: (i) temperature at which the cultures were incubated prior to exposure to disinfectants, (ii) growth phase of the cultures at the time of exposure to disinfectants, (iii) nature of the suspending menstruum for disinfectants, and (iv) exposure to fluorescent light during incubation of inocula prior to testing. The applied significance of these findings may alter the present concepts of disinfectant testing as well as routine control procedures in the hospital environment.

Acetates↗

Pseudomonas aeruginosa: growth in distilled water from hospitals.

Pseudomonas aeruginosa can grow relatively fast in distilled water obtained in hospitals and achieve high cell contaminations which remain stable for long periods of time. Cells grown in distilled water react quite differently to chemical and physical stresses than cells grown in standard laboratory culture media.

Bacteriological Techniques↗

Relative frequency distribution of d(125 C) values for spore isolates from the mariner-Mars 1969 spacecraft.

Bacterial spore crops were prepared from 103 randomly selected aerobic mesophilic isolates collected during a spore assay of Mariner-Mars 1969 spacecraft conducted by the Jet Propulsion Laboratory. D(125 c) values, which were determined by the fractional-replicate-unit-negative-most-probable number assay method using a forced air oven, ranged from less than 5 min to a maximum of 58 min. Subsequent identification of the 103 isolates indicated that there was no relationship between species and dry-heat resistance. A theoretical dry-heat survival curve of the "population" was nonlinear. The slope of this curve was determined almost exclusively by the more resistant organisms, although they represented only a small portion of the "population."

Journal Article↗

Dry-heat inactivation kinetics of naturally occurring spore populations.

Twenty-three soil samples were collected from areas of the United States where major spacecraft assembly and launch facilities are in operation. Soil samples were treated with ethyl alcohol, ultrasonic energy, and gross filtration. The resultant suspensions consisted of viable, naturally occurring bacterial spores and were used to inoculate stainless-steel strips. The strips were suspended in a forced air oven and assays were made at 5-min intervals for the number of viable spores. Most survivor curves were nonlinear. Subsequently, spore crops of heat-sensitive and heat-resistant soil isolates were found to have linear survivor curves at 125 C which were unaffected by the presence or absence of sterile soil particles from the parent sample. When two spore crops, one of which was heat-resistant and the other heat-sensitive, were mixed, the resultant nonlinear curves were unaffected by the presence or absence of sterile parent soil. Therefore, the survivor curves obtained originally with the soils were the result of heterogeneous spore populations rather than of protection afforded by soil particles in our test system. These results question the rationale both of assuming logarithmic death and of using decimal-reduction values obtained with subcultured standard reference spores in the derivation of dry-heat sterilization cycles for items contaminated with naturally occurring spore populations.

Journal Article↗

Comparison of microbial contamination levels among hospital operating rooms and industrial clean rooms.

Microbial contamination in industrial clean rooms was compared quantitatively and qualitatively with that of hospital operating rooms. The number of aerobic mesophilic microorganisms which accumulated on stainless-steel strips exposed for periods up to 21 weeks to the intramural air of four operating rooms was at least 1 log higher than the accumulation on strips exposed in four clean rooms, and was essentially the same as that found in two factory areas. Volumetric air samplings showed that there were significantly higher numbers of airborne viable particles per cubic foot of air in operating rooms than in industrial clean rooms. In contrast to clean rooms, where most of the airborne contaminants were those associated with human hair, skin, and respiratory tract, the hospital operating rooms showed a very high level of microorganisms associated with dust and soil.

Air Microbiology↗