PubMed Health⌕ Search

Biomedical subjects

M S Firstenberg

Publications and source records attributed to M S Firstenberg.

34 records · Page 2Linked to original sources

Color M-mode Doppler flow propagation velocity is a preload insensitive index of left ventricular relaxation: animal and human validation.

OBJECTIVES: To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). BACKGROUND: The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. METHODS: We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. RESULTS: In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). CONCLUSIONS: Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.

Aged↗

Disk embolization of a Björk-Shiley convexo-concave mitral valve: a cause of sudden cardiovascular collapse and mesenteric ischemia.

Strut fracture and disk embolization of a Björk-Shiley convexo-concave valve is uncommon, but it should always be considered as a cause of sudden cardiovascular collapse in patients with such valves. Recognition of this clinical scenario is essential, given the importance of early diagnosis and the prevalence of these valves worldwide. We present a fatal case of disk embolization of a mitral prosthesis presenting with cardiogenic shock and mesenteric ischemia.

Aged↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging.

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Adult↗

Transesophageal echocardiography assessment of severe ostial left main coronary stenosis.

Doppler echocardiography is commonly used in the assessment of stenotic valvular orifices. We describe the application of transesophageal echocardiography for the detection of a critical ostial left main coronary stenosis. Because preoperative coronary angiography often is not routinely performed in young patients undergoing valve surgery, application of Doppler echocardiography can potentially prevent catastrophic complications, particularly in atypical cases.

Adult↗

Real-time transmission of full-motion echocardiography over a high-speed data network: impact of data rate and network quality of service.

UNLABELLED: With high-resolution network transmission required for telemedicine, education, and guided-image acquisition, the impact of errors and transmission rates on image quality needs evaluation. METHODS: We transmitted clinical echocardiograms from 2 National Aeronautics and Space Administration (NASA) research centers with the use of Motion Picture Expert Group-2 (MPEG-2) encoding and asynchronous transmission mode (ATM) network protocol over the NASA Research and Education Network. Data rates and network quality (cell losses [CLR], errors [CER], and delay variability [CVD]) were altered and image quality was judged. RESULTS: At speeds of 3 to 5 megabits per second (Mbps), digital images were superior to those on videotape; at 2 Mbps, images were equivalent. Increasing CLR caused occasional, brief pauses. Extreme CER and CDV increases still yielded high-quality images. CONCLUSIONS: Real-time echocardiographic acquisition, guidance, and transmission is feasible with the use of MPEG-2 and ATM with broadcast quality seen above 3 Mbps, even with severe network quality degradation. These techniques can be applied to telemedicine and used for planned echocardiography aboard the International Space Station.

Artifacts↗

Doppler echo evaluation of pulmonary venous-left atrial pressure gradients: human and numerical model studies.

The simplified Bernoulli equation relates fluid convective energy derived from flow velocities to a pressure gradient and is commonly used in clinical echocardiography to determine pressure differences across stenotic orifices. Its application to pulmonary venous flow has not been described in humans. Twelve patients undergoing cardiac surgery had simultaneous high-fidelity pulmonary venous and left atrial pressure measurements and pulmonary venous pulsed Doppler echocardiography performed. Convective gradients for the systolic (S), diastolic (D), and atrial reversal (AR) phases of pulmonary venous flow were determined using the simplified Bernoulli equation and correlated with measured actual pressure differences. A linear relationship was observed between the convective (y) and actual (x) pressure differences for the S (y = 0.23x + 0.0074, r = 0.82) and D (y = 0.22x + 0.092, r = 0.81) waves, but not for the AR wave (y = 0. 030x + 0.13, r = 0.10). Numerical modeling resulted in similar slopes for the S (y = 0.200x - 0.127, r = 0.97), D (y = 0.247x - 0. 354, r = 0.99), and AR (y = 0.087x - 0.083, r = 0.96) waves. Consistent with numerical modeling, the convective term strongly correlates with but significantly underestimates actual gradient because of large inertial forces.

Atrial Function↗

Internet-based transfer of cardiac ultrasound images.

A drawback to large-scale multicentre studies is the time required for the centralized evaluation of diagnostic images. We evaluated the feasibility of digital transfer of echocardiographic images to a central laboratory for rapid and accurate interpretation. Ten patients undergoing trans-oesophageal echocardiographic scanning at three sites had representative single images and multiframe loops stored digitally. The images were analysed in the ordinary way. All images were then transferred via the Internet to a central laboratory and reanalysed by a different observer. The file sizes were 1.5-72 MByte and the transfer rates achieved were 0.6-4.8 Mbit/min. Quantitative measurements were similar between most on-site and central laboratory measurements (all P > 0.25), although measurements differed for left atrial width and pulmonary venous systolic velocities (both P < 0.05). Digital transfer of echocardiographic images and data to a central laboratory may be useful for multicentre trials.

Cardiovascular Diseases↗

Selective management of pediatric pancreatic injuries.

BACKGROUND: Despite trauma being the most common cause of pediatric pancreatitis, the diagnosis and management is often difficult. METHODS: The hospital course, diagnostic and surgical procedures, and complications for all children with traumatic pancreatitis evaluated at a Regional Level I Trauma Center were reviewed retrospectively. RESULTS: Twelve of 3,500 children (0.35%, mean age, 8.7 +/- 1.2 years) were reviewed. Intraoperative diagnosis was made in three after penetrating trauma. Nine children sustained blunt pancreatic trauma (BPT) with serial radiographic imaging confirming the diagnosis in seven. Serial serum amylase levels, when performed, were normal in two and elevated in six, but did not predict injury severity or need for further intervention. Endoscopic retrograde cholangiopancreatography was performed in three children and indicated the need for surgical intervention in two and prevented planned laparotomy in one. Two children underwent computed tomography-guided fluid drainage. Pseudocysts developed in five children. Mortality rate from penetrating injuries was 66% with no deaths from BPT. CONCLUSIONS: A combination of serial radiographic, laboratory, and ERCP findings will improve the diagnosis and management of BPT. Penetrating or main ductal injuries require surgical intervention, and fluid collections may require drainage, but, otherwise, most BPT can be managed nonoperatively with minimal morbidity and mortality.

Adolescent↗

Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow.

OBJECTIVES: The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND: Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS: Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS: In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS: A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.

Adult↗

Semi-automated analysis of color M-mode echocardiographic images for determining transmitral pressure gradients using a simplified Euler equation.

UNLABELLED: We hypothesize that a simplified version of the Euler equation (SEE) utilizing differences in velocity over a distance and time as obtained by Color Doppler M-mode (CMM) echocardiography can approximate actual peak transmitral pressure gradients deltaP(TM). METHODS: In 14 patients undergoing open-heart surgery, deltaP(TM) was measured under various hemodynamic conditions using 2 high fidelity transducers, 5 cm apart. Transesophageal CMM images were simultaneously acquired and a customized image analysis application was used to abstract spatiotemporal velocity characteristics. Using both the SEE and a simplified Bernoulli equations, deltaP(TM) were determined and compared to the actual deltaP(TM). RESULTS: While the simplified Bernoulli equation resulted in a poor estimate (y=0.075x+0.71, r=0.45), the deltaP(TM) obtained using the SEE correlated strongly (y=0.79x+0.48, r=0.91) with the actual measurements. CONCLUSIONS: Semi-automated analysis of CMM images using a SEE can accurately estimate actual deltaP(TM).

Algorithms↗

Gastrointestinal surgery during pregnancy.

Gastrointestinal surgical problems often mimic symptoms and signs of nonsurgical conditions that occur during pregnancy. This mimicry presents a particular challenge to diagnosis because avoiding a delay in treatment is critical to successful management. Some of these conditions, such as acute appendicitis and biliary colic, are common in younger women; however, the anatomic and physiologic changes of pregnancy can alter their usual manner of presentation. Many elective and urgent operations can be performed during pregnancy with minimal risk to the mother and fetus. The mother's condition should always take priority because her proper treatment usually benefits the fetus as well.

Digestive System Diseases↗

Catheter ablation of the atrioventricular junction using radiofrequency energy and a bilateral cardiac approach.

Radiofrequency current catheter ablation was used successfully to create complete atrioventricular (AV) block in 60 of 61 patients (98%) with drug refractory supraventricular tachyarrhythmias. The remaining patient developed Mobitz I AV block and is clinically improved (clinical efficacy 100%). In 54 patients (89%), complete AV block was achieved using a right-sided approach. Patients aged > 60 years needed significantly fewer right-sided radiofrequency applications to produce complete AV block (5.3 +/- 5.3 vs 11.1 +/- 10.0; p = 0.009). In 6 of 7 patients with unsuccessful right-sided ablation, a left ventricular approach was used. In each case, 1 to 4 additional radiofrequency applications produced complete AV block. Patients with unsuccessful right-sided ablation were generally younger than those with successful ablation (50 +/- 16 vs 64 +/- 11; p = 0.007). It is concluded that catheter ablation using radiofrequency current is an extremely effective means of producing complete AV block. Older patients appear to be more susceptible to right-sided radiofrequency approaches. Left ventricular ablation easily produces complete AV block in patients refractory to right-sided attempts.

Adult↗

Analysis of deaths in patients with an implantable cardioverter defibrillator.

The cause of death and clinical characteristics of 26 patients that died after implantable cardioverter defibrillator placement were reviewed and compared to the 145 patients still living after a mean follow-up of 17 months. Operative mortality was 4% (7/171) and resulted from postoperative ventricular arrhythmias (four patients), heart failure (two patients), and respiratory failure (one patient). Operative mortality was significantly higher (1.7% vs 9.6%, P less than 0.05) following concomitant surgical procedures. Total late mortality was 11% (18/171). Thirteen deaths (75%) occurred in-hospital from progressive deterioration of left ventricular function (nine patients), arrhythmia (two patients), and noncardiac causes (two patients). Outpatient mortality was 3.5% (6/171) and resulted from presumed sudden cardiac death in five of six patients; two of the five had devices that were inactive, one had high defibrillation thresholds, and two had suspected bradyarrhythmic deaths. One postoperative death and one late in-hospital death were also considered sudden cardiac deaths for a total of seven patients with defibrillation system failures. By multivariant analysis, preoperative clinical characteristics associated with a worse prognosis following defibrillator implantation were identified: presentation as ventricular tachycardia (P less than 0.02), induction of sustained monomorphic ventricular tachycardia (P less than 0.05), poor left ventricular performance (P less than 0.01), poor functional status (P less than 0.001), and the use of diuretics (P less than 0.01). Frequent device discharges (P less than 0.001) and concomitant antitachycardia pacing systems (P less than 0.001) were markers for greater arrhythmia recurrence and were potent predictors of a worse prognosis and particularly sudden death.

Arrhythmias, Cardiac↗