PubMed Health⌕ Search

Biomedical subjects

M S Lipton

Publications and source records attributed to M S Lipton.

9 recordsLinked to original sources

High-throughput peptide identification from protein digests using data-dependent multiplexed tandem FTICR mass spectrometry coupled with capillary liquid chromatography.

Tandem mass spectrometry (MS/MS) plays an important role in the unambiguous identification and structural elucidation of biomolecules. In contrast to conventional MS/MS approaches for protein identification where an individual polypeptide is sequentially selected and dissociated, a multiplexed-MS/MS approach increases throughput by selecting several peptides for simultaneous dissociation using either infrared multiphoton dissociation (IRMPD) or multiple frequency sustained off-resonance irradiation (SORI) collisionally induced dissociation (CID). The high mass measurement accuracy and resolution of FTICR combined with knowledge of peptide dissociation pathways allows the fragments arising from several different parent ions to be assigned. Herein we report the application of multiplexed-MS/MS coupled with on-line separations for the identification of peptides present in complex mixtures (i.e., whole cell lysate digests). Software was developed to enable "on-the-fly" data-dependent peak selection of a subset of polypeptides from each FTICR MS acquisition. In the subsequent MS/MS acquisitions, several coeluting peptides were fragmented simultaneously using either IRMPD or SORI-CID techniques. The utility of this approach has been demonstrated using a bovine serum albumin tryptic digest separated by capillary LC where multiple peptides were readily identified in single MS/MS acquisitions. We also present initial results from multiplexed-MS/MS analysis of a D. radiodurans whole cell digest to illustrate the utility of this approach for high-throughput analysis of a bacterial proteome.

Amino Acid Sequence↗

Quantitative analysis of bacterial and mammalian proteomes using a combination of cysteine affinity tags and 15N-metabolic labeling.

We describe the combined use of 15N-metabolic labeling and a cysteine-reactive biotin affinity tag to isolate and quantitate cysteine-containing polypeptides (Cys-polypeptides) from Deinococcus radiodurans as well as from mouse B16 melanoma cells. D. radiodurans were cultured in both natural isotopic abundance and 15N-enriched media. Equal numbers of cells from both cultures were combined and the soluble proteins extracted. This mixture of isotopically distinct proteins was derivatized using a commercially available cysteine-reactive reagent that contains a biotin group. Following trypsin digestion, the resulting modified peptides were isolated using immobilized avidin. The mixture was analyzed by capillary reversed-phase liquid chromatography (LC) online with ion trap mass spectrometry (MS) as well as Fourier transform ion cyclotron resonance (FTICR) MS. The resulting spectra contain numerous pairs of Cyspolypeptides whose mass difference corresponds to the number of nitrogen atoms present in each of the peptides. Designation of Cys-polypeptide pairs is also facilitated by the distinctive isotopic distribution of the 15N-labeled peptides versus their 14N-labeled counterparts. Studies with mouse B16 cells maintained in culture allowed the observation of hundreds of isotopically distinct pairs of peptides by LC-FTICR analysis. The ratios of the areas of the pairs of isotopically distinct peptides showed the expected 1:1 labeling of the 14N and 15N versions of each peptide. An additional benefit from the present strategy is that the 15N-labeled peptides do not display significant isotope-dependent chromatographic shifts from their 14N-labeled counterparts, therefore improving the precision for quantitating peptide abundances. The methodology presented offers an alternate, cost-effective strategy for conducting global, quantitative proteomic measurements.

Animals↗

Packed capillary reversed-phase liquid chromatography with high-performance electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry for proteomics.

In this study, high-efficiency packed capillary reversed-phase liquid chromatography (RPLC) coupled on-line with high-performance Fourier transform ion cyclotron resonance (FTICR) mass spectrometry has been investigated for the characterization of complex cellular proteolytic digests. Long capillary columns (80-cm) packed with small (3-micron) C18 bonded particles provided a total peak capacity of approximately 1000 for cellular proteolytic polypeptides when interfaced with an ESI-FTICR mass spectrometer under composition gradient conditions at a pressure of 10,000 psi. Large quantities of cellular proteolytic digests (e.g., 500 micrograms) could be loaded onto packed capillaries of 150-micron inner diameter without a significant loss of separation efficiency. Precolumns with suitable inner diameters were found useful for improving the elution reproducibility without a significant loss of separation quality. Porous particle packed capillaries were found to provide better results than those containing nonporous particles because of their higher sample capacity. Two-dimensional analyses from the combination of packed capillary RPLC with high-resolution FTICR yield a combined capacity for separations of > 1 million polypeptide components and simultaneously provided information for the identification of the separated components based upon the accurate mass tag concept previously described.

Chromatography, Liquid↗

Rapid quantitative measurements of proteomes by Fourier transform ion cyclotron resonance mass spectrometry.

The patterns of gene expression, post-translational modifications, protein/biomolecular interactions, and how these may be affected by changes in the environment, cannot be accurately predicted from DNA sequences. Approaches for proteome characterization are generally based upon mass spectrometric analysis of in-gel digested two dimensional polyacrylamide gel electrophoresis (2-D PAGE) separated proteins, allowing relatively rapid protein identification compared to conventional approaches. This technique, however, is constrained by the speed of the 2-D PAGE separations, the sensitivity limits intrinsic to staining necessary for protein visualization, the speed and sensitivity of subsequent mass spectrometric analyses for identification, and the limited ability for accurate quantitative measurements based on differences in spot intensity. We are presently developing alternative approaches for proteomics based upon the combination of fast capillary electrophoresis, or other suitable chromatographic separations, and the high mass accuracy and sensitivity obtainable with unique Fourier transform ion cyclotron resonance (FTICR) mass spectrometers available at our laboratory. Several approaches are presently being pursued; one based upon the analysis of intact proteins and the second upon approaches for global protein digestion and accurate peptide mass analysis. Quantitation of protein/peptide levels are based on using two or more stable-isotope labeled versions of proteomes which are combined to obtain precise quantitation of relative protein abundances. We describe the status of our efforts towards the development of a high-throughput proteomics capability and present initial results for application to several microorganisms and discuss our efforts for extending the developed capability to mammalian proteomes.

Bacterial Proteins↗

Characterization of microorganisms and biomarker development from global ESI-MS/MS analyses of cell lysates.

The capability for sensitive and accurate identification of microorganisms has potential applications that include the monitoring of industrial bioprocessing operations, food safety analyses, disease diagnosis, and detection of potential biological hazards. Efforts based upon matrix-assisted laser desorption/ionization mass spectrometry to detect and identify specific microorganisms have been actively pursued for several years. We report a new method being developed to select useful biomarkers for the identification of microorganisms based upon electrospray ionization (ESI)-ion trap mass spectrometry. Crude cell lysates are processed using a recently developed dualmicrodialysis device and then directly infused into an ion trap MS. The low ESI flow rate and precursor ion accumulation capability of the ion trap MS enables high-sensitivity MS/MS analyses. Precursor ions are automatically selected and analyzed using tandem MS (MS/MS) to produce "global" MS/MS surveys and processed to yield two-dimensional MS/MS spectral displays. Such global MS/MS surveys are demonstrated for Escherichia coli lysates. The distinctive MS/MS spectral patterns can be used to identify mass spectrometric-detected species useful as biomarkers, which then provide a basis for confident microorganism identification. The results presented demonstrate the application of this method for the identification of microorganisms, as well as for detection of bacteriophage MS2 in the presence of a large excess of E. coli.

Biomarkers↗

Mass spectrometric detection for capillary isoelectric focusing separations of complex protein mixtures.

Capillary isoelectric focusing (CIEF) can provide high-resolution separations of complex protein mixtures, but until recently it has primarily been used with conventional UV detection. This technique would be greatly enhanced by much more information-rich detection methods that can aid in protein characterization. We describe progress in the development of the combination of CIEF with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry and its application to proteome characterization. Studies have revealed 400-1000 putative proteins in the mass range of 2-100 kDa from total injections of approximately 300 ng protein in single CIEF-FTICR analyses of cell lysates for both Escherichia coli (E. coli) and Deinococcus radiodurans (D. radiodurans). We also demonstrate the use of isotope labeling of the cell growth media to improve mass measurement accuracy and provide a means for quantitative proteome-wide measurements of protein expression. The ability to make such comprehensive and precise measurements of differences in protein expression in response to cellular perturbations should provide new insights into complex cellular processes.

Bacterial Proteins↗

Probing proteomes using capillary isoelectric focusing-electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

Unlike the genome, the proteome is exquisitely sensitive to cellular conditions and will consist of proteins having abundances dependent upon stage in the cell cycle, cell differentiation, response to environmental conditions (nutrients, temperature, stress etc.), or disease state(s). Therefore, the study of proteomes under well-defined conditions can provide a better understanding of complex biological processes and inference of protein function. Thus, much faster, more sensitive, and precise capabilities for the characterization of cellular constituents are desired. We describe progress in the development and initial application of the powerful combination of capillary isoelectric focusing (CIEF) and Fourier transform ion cyclotron resonance (FTICR) mass spectrometry for measurements of the proteome of the model system Escherichia coli. Isotope depletion of the growth media has been used to improve mass measurement accuracy, and the comparison of CIEF-FTICR results for the analysis of cell lysates harvested from E. coli cultured in normal and isotopically depleted media are presented. The initial studies have revealed 400-1000 putative proteins in the mass range 2-100 kDa from total injections of approximately 300 ng of E. coli proteins in a single CIEF-FTICR analysis.

Bacterial Proteins↗

Analysis of radiation induced nucleobase-peptide crosslinks by electrospray ionization mass spectrometry.

Upon exposure to ionizing radiation, DNA undergoes a variety of modifications including the production of a covalent bond between the nucleobase thymine and the amino acid tyrosine. These crosslinked lesions, produced in cells exposed to ionizing radiation, if unrepaired are thought to result in cell death. We have used electrospray ionization mass spectrometry (ESI-MS) to study a model system consisting of the peptide angiotensin, a 10 amino acid peptide containing only one tyrosine residue, irradiated in the presence of the nucleobase thymine. The presence of the covalently crosslinked species has been determined by ESI-MS, by the appearance of additional species in the irradiated samples which correspond to the adduction of thymine as well as a hydrated species containing thymine and water (5-hydroxy-6-hydrothymine). The formation of 5-hydroxy-6-hydrothymine adduct is reversible and the relative abundance of the thymine and 5-hydroxy-6-hydrothymine adducts is dependent on the pH of the spray solution. High resolution experiments using Fourier transform ion cyclotron resonance mass spectrometry confirms the presence of the thymine and hydrated thymine adducts. The high resolution nature of these experiments also allows the detection of a 5,6-dihydrothymine adduct.

Angiotensin II↗