The Gore Excluder endograft device for the treatment of abdominal aortic aneurysms.

UNLABELLED: Open surgical repair on abdominal aortic aneurysms has been performed for many years with good RESULTS: Despite the many advances in medical care, the procedure is still associated with many complications. The Gore Excluder endograft is a third-generation endograft that became the third commercially available endograft approved in the United States. Data from multiple trials have compared the use of the Excluder endograft to open repair and have shown favorable RESULTS: This review shall summarize the clinical use of the Excluder endograft from its initial clinical trial in 1998 to its current commercial use.

Aortic Aneurysm, Abdominal↗

The Ancure endografting system: an update.

The Ancure endografting system (Guidant Cardiac and Vascular Division, Menlo Park, Calif) features a unibody, nonsupported woven polyester graft designed to treat abdominal aortic aneurysms. It is constructed in tube, bifurcated, and aortoiliac configurations. The attachment system consists of a frame with four independent V-shaped double hooks that penetrate the arterial wall for fixation. There are separate attachment systems at the proximal and distal ends of the endoprosthesis. In September 1999, the Food and Drug Administration (FDA) approved the tube and bifurcated devices for general use. The aortoiliac device is under present consideration of the FDA. Phase II and III clinical trials of the system enrolled over 870 patients from the end of 1995 to the summer of 1999. The device was deployed successfully in 90% to 96% of cases, depending on the configuration and the phase of the trial. Mortality rates were similar to those of concurrent open surgical control rates, but serious morbidity was reduced. Long-term follow-up of the bifurcated group from phase II showed only one migration and no ruptures. Aneurysm size reduction in this group was noted in 51.3% of patients at 1 year and 68.5% at 2 years. In the same subset, type I endoleaks were noted in 2.7% at 1 year and 1.3% at 2 years. All postoperative imaging studies were reviewed by a core laboratory facility. The advantages of the ancure system include solid fixation, flexibility in accommodating morphologic changes, and excellent long-term clinical performance. The disadvantages include a large introducer system and the potential for limb obstruction by compression or angulation. However, limb compromise responds well to intraluminal stenting. The expected FDA approval of the aortoiliac device and a larger variety of graft sizes should expand the number of patients who can be treated with this system.

Angioplasty↗

Is proximal aortic neck dilatation after endovascular aneurysm exclusion a cause for concern?

PURPOSE: The purpose of this study was to evaluate the extent and frequency of dilatation of the proximal aortic neck over time after endovascular exclusion of abdominal aortic aneurysms and the effect on the continued integrity of the repair. METHODS: Patients enrolled in the multicenter tube and bifurcated trials of the Guidant-Endovascular Technologies Ancure endografting system and at least 1 year of follow-up were reviewed. Neck diameter measurements were obtained from computed tomography scans that were obtained with and without contrast by an independent core laboratory facility. The diameter was considered to be the minor axis of the first slice at which point at least one half of the proximal attachment frame was located. A change exceeding 2.5 mm was considered to be significant. RESULTS: At 1 year, 13% of the patients (42/314 patients) showed evidence of proximal neck dilatation, with a mean diameter increase of 4.8 +/- 2.4 mm. The proportion of patients with dilatation increased to 21% at 2 years (48/226 patients) and 19% at 3 years (11/59 patients). The initial presence of an endoleak, the neck length, and the aneurysm size had no clear effect on the development of neck enlargement. Initial neck diameter was inversely related to and the strongest predictor of later dilatation. Graft oversizing was not an independent predictor of neck dilatation on multivariate analysis. Only one migration of the proximal attachment system was observed during follow-up. CONCLUSION: Most proximal aortic necks remain stable, but approximately 20% of necks increase in diameter by 2 years. Smaller necks dilate more often than larger ones. This effect is independent from the frequent oversizing of grafts in smaller necks. The integrity of the repair remains good at 3 years of follow-up.

Analysis of Variance↗

Outcome events in patients with claudication: a 15-year study in 2777 patients.

OBJECTIVE: The purpose of this study was to delineate the natural history of claudication and determine risk factors for death. METHODS: We reviewed the key outcomes (death, revascularization, amputation) in 2777 male patients with claudication identified over 15 years at a Veterans Administration hospital with both clinical and noninvasive criteria. Patients with rest pain or ulcers were excluded. Data were analyzed with life-table and Cox hazard models. RESULTS: The mean follow-up was 47 months. The cohort exhibited a mortality rate of 12% per year, which was significantly (P <.05) more than the age-adjusted US male population. Among the deaths in which the cause was known, 66% were due to heart disease. We examined several baseline risk factors in a multivariate Cox model. Four were significant (P <.01) independent predictors of death: older age (relative risk [RR] = 1.3 per decade), lower ankle-brachial index (RR = 1.2 for 0.2 change), diabetes requiring medication (RR = 1.4), and stroke (RR = 1.4). The model can be used to estimate the mortality rate for specific patients. Surprisingly, a history of angina and myocardial infarction was not a significant predictor. Major and minor amputations had a 10-year cumulative rate less than 10%. Revascularization procedures occurred with a 10-year cumulative rate of 18%. CONCLUSIONS: We found a high mortality rate in this large cohort and four independent risk factors that have a large impact on survival. Risk stratification with our model may be useful in determining an overall therapeutic plan for claudicants. A history of angina and myocardial infarction was not a useful predictor of death, suggesting that many patients in our cohort presented with claudication before having coronary artery symptoms. Our data also indicate that claudicants have a low risk of major amputation at 10-year follow-up.

Aged↗

Adenovirus-mediated gene transfer of human inducible nitric oxide synthase in porcine vein grafts inhibits intimal hyperplasia.

OBJECTIVE: The aim of this study is to determine whether adenoviral inducible nitric oxide synthase (iNOS) gene transfer could inhibit intimal hyperplasia (IH) in porcine internal jugular veins interposed into the carotid artery circulation. METHODS: Porcine internal jugular veins were transduced passively with 1 x 10(11) particles of an adenoviral vector carrying either the human iNOS (AdiNOS) or beta-galactosidase (AdlacZ) cDNA for 30 minutes and then interposed into the carotid artery circulation. Segments of each vein graft were maintained in an ex vivo organ culture to measure nitrite accumulation, a marker of nitric oxide synthesis. The grafts were analyzed immunohistochemically for the presence of neutrophils, macrophages, and leukocytes by staining for myeloperoxidase, ED1, and CD45, respectively, at 3 (n = 4) and 7 (n = 4) days. Morphometric analyses and cellular proliferation (Ki67 staining) were assessed at 3 (n = 4), 7 (n = 4), and 21 days (n = 8). RESULTS: AdlacZ-treated vein grafts demonstrated high levels of beta-galactosidase expression at 3 days with a gradual decline thereafter. Nitrite production from AdiNOS-treated vein grafts was approximately fivefold greater than AdlacZ-treated grafts (P =.00001). AdiNOS or AdlacZ treatment was associated with minimal graft inflammation. Cellular proliferation rates were significantly reduced in AdiNOS-treated grafts as compared with controls at both 3 (41%, P =.000004) and 7 days (32%, P =.0001) after bypass. This early antiproliferative effect was most pronounced at the distal anastomosis (65%, P =.0005). The iNOS gene transfer reduced the intimal/medial area ratio in vein grafts at 7 (36%, P =.009) and 21 days (30%, P =.007) versus controls. This inhibition of IH was again more prominent in the distal segments of the grafts (P =.01). CONCLUSION: Adenovirus-mediated iNOS gene transfer to porcine internal jugular vein grafts effectively reduced cellular proliferation and IH. Although iNOS gene transfer reduced IH throughout the entire vein graft, the most pronounced effect was measured at the distal anastomosis. These results suggest potential for iNOS-based genetic modification of vein grafts to prolong graft patency.

Adenoviridae↗

Association of intraluminal thrombus in abdominal aortic aneurysm with local hypoxia and wall weakening.

PURPOSE: Our previous computer models suggested that intraluminal thrombus (ILT) within an abdominal aortic aneurysm (AAA) attenuates oxygen diffusion to the AAA wall, possibly causing localized hypoxia and contributing to wall weakening. The purpose of this work was to investigate this possibility. METHODS: In one arm of this study, patients with AAA were placed in one of two groups: (1) those with an ILT of 4-mm or greater thickness on the anterior surface or (2) those with little (< 4 mm) or no ILT at this site. During surgical resection but before aortic cross-clamping, a needle-type polarographic partial pressure of oxygen (PO2) electrode was inserted into the wall of the exposed AAA, and the PO2 was measured. The probe was advanced, and measurements were made midway through the thrombus and in the lumen. Mural and mid-ILT PO2 measurements were normalized by the intraluminal PO2 measurement to account for patient variability. In the second arm of this study, two AAA wall specimens were obtained from two different sites of the same aneurysm at the time of surgical resection: group I specimens had thick adherent ILT, and group II specimens had thinner or no adherent ILT. Nonaneurysmal tissue was also obtained from the infrarenal aorta of organ donors. Specimens were subjected to histologic, immunohistochemical, and tensile strength analyses to provide data on degree of inflammation (% area inflammatory cells), neovascularization (number of capillaries per high-power field), and tensile strength (peak attainable load). Additional specimens were subjected to Western blotting and immunohistochemistry for qualitative evaluation of expression of the cellular hypoxia marker oxygen-regulated protein. RESULTS: The PO2 measured within the AAA wall in group I (n = 4) and group II (n = 7) patients was 18% +/- 9% luminal value versus 60% +/- 6% (mean +/- SEM; P <.01). The normalized PO2 within the ILT of group I patients was 39% +/- 10% (P =.08 with respect to the group I wall value). Group I tissue specimens showed greater inflammation (P <.05) compared with both group II specimens and nonaneurysmal tissue: 2.9% +/- 0.6% area (n = 7) versus 1.7% +/- 0.3% area (n = 7) versus 0.2% +/- 0.1% area (n = 3), respectively. We found similar differences for neovascularization (number of vessels/high-power field), but only group I versus control was significantly different (P <.05): 16.9 +/- 1.6 (n = 7) vs 13.0 +/- 2.3 (n = 7) vs 8.7 +/- 2.0 (n = 3), respectively. Both Western blotting and immunohistochemistry results suggest that oxygen-regulated protein is more abundantly expressed in group I versus group II specimens. Tensile strength of group I specimens was significantly less (P <.05) than that for group II specimens: 138 +/- 19 N/cm2 (n = 7) versus 216 +/- 34 N/cm2 (n = 7), respectively. CONCLUSION: Our results suggest that localized hypoxia occurs in regions of thicker ILT in AAA. This may lead to increased, localized mural neovascularization and inflammation, as well as regional wall weakening. We conclude that ILT may play an important role in the pathology and natural history of AAA.

Aged↗

Exclusion of accessory renal arteries during endovascular repair of abdominal aortic aneurysms.

OBJECTIVE: Adequate proximal neck length is important for proper endovascular treatment of abdominal aortic aneurysms (AAAs). Placement of endografts in AAAs with relatively short proximal necks may require covering the origin of accessory renal arteries. Exclusion of these arteries carries the theoretical concern of regional renal ischemia associated with loss of parenchyma or worsening hypertension. We reviewed our experience with accessory renal exclusions during endovascular AAA repair to determine the frequency and severity of complications. METHODS: Complete records were available for review on 311 of 325 consecutive patients treated with endovascular grafts for AAAs from February 6, 1996, to March 15, 2001. The presence of accessory renal arteries was ascertained from preoperative/intraoperative aortography or from computed tomographic scanning. Sizes of the accessories were measured by using the main renal arteries as a reference. Considerations for excluding the accessory renal arteries were based on the likelihood of successful proximal attachment to healthy aorta, an accessory vessel whose size does not exceed the diameter of the main renal artery, and the absence of renal disease. RESULTS: The mean follow-up was 11.5 months. Fifty-two accessory renal arteries were documented in 37 patients (12%), ranging from 1 to > or =3 per patient. Of these, 26 accessory renal arteries were covered in 24 patients. Patients ranged in age from 57 to 85 years (mean, 74.1 years), with 20 men and 4 women. The Ancure device was used in 23 patients and the Excluder device in one. Of the accessories excluded, 22 originated above the aneurysm and 4 originated directly from the aneurysm itself. There were no perioperative mortalities. One patient died 5 months after surgery from an unrelated condition. There was one type I (distal) endoleak and no type II endoleaks. Five patients (21%) had segmental renal infarction associated with the side of accessory renal artery exclusion. Only one patient with segmental infarction had significant postoperative hypertension that resulted in changes in blood pressure medication. The blood pressure reverted to normal 3 months later. One patient with a stenotic left main renal artery required exclusion of the accessory renal artery for successful proximal attachment. Serum creatinine levels remained unchanged throughout follow-up in all but one patient, in whom progressive postoperative renal failure developed despite normal renal flow scan, presumably from intraoperative manipulation and contrast nephropathy. CONCLUSION: Exclusion of accessory renal arteries to facilitate endovascular AAA repair appears to be well tolerated. Long-term sequelae seem infrequent and mild.

Aged↗

Quality of life assessment in patients undergoing endovascular or conventional AAA repair.

PURPOSE: To compare health-related quality of life outcomes in a cohort of abdominal aortic aneurysm (AAA) patients treated concurrently with either a conventional or endoluminal intervention. METHODS: Between December 1997 and April 1999, 51 AAA patients treated by either open or endovascular techniques were enrolled in this prospective study. Conventional therapy was performed in 26 patients (19 men; mean age 70.4 +/- 6.0 years) with anatomical features unsuitable for the endovascular approach. Twenty-five patients (23 men; mean age 70.7 +/- 7.2 years) underwent endoluminal AAA exclusion using either the Ancure or bifurcated Enduring stent-grafts. The Medical Outcomes Study Short-Form 36-item health survey was administered preoperatively and at 1, 4, 8, and > or = 52 weeks after discharge. RESULTS: At 1 week, both groups showed significant reductions (p < 0.001) in mean scores compared to baseline in 4 dimensions (physical function, social function, role-physical, and vitality), but the decline was more pronounced in patients having open repair. Endoluminal patients returned to their baseline scores by the 4th postoperative week, whereas complete recovery to baseline in the conventional patients was delayed to the 8th week. CONCLUSIONS: Patients treated endoluminally exhibit better physical and functional scores as early as 1 week after discharge; they also return to baseline status significantly earlier than the conventional group. These findings document the perceived advantage of endovascular therapy over conventional AAA treatment.

Aged↗

The aneurysm detection and management study screening program: validation cohort and final results. Aneurysm Detection and Management Veterans Affairs Cooperative Study Investigators.

BACKGROUND: We previously reported the prevalence and associations of abdominal aortic aneurysm (AAA) in 73451 veterans aged 50 to 79 years who underwent ultrasound screening. OBJECTIVE: To understand the prevalence of and principal positive and negative risk factors for AAA, and to assess reproducibility of our previous findings. METHODS: In the new cohort of veterans undergoing screening, 52 745 subjects aged 50 to 79 without history of AAA underwent successful ultrasound screening for AAA, after completing a questionnaire on demographics and potential risk factors. RESULTS: We detected AAA of 4.0 cm or larger in 613 participants (1.2%; compared with 1.4% in the earlier cohort). The direction and magnitude of the important associations reported in the first cohort were confirmed. Respective odds ratios for the major associations with AAA for the second and for the combined cohorts were as follows: 1.81 and 1.71 for age (per 7 years), 0.12 and 0. 18 for female sex, 0.59 and 0.53 for black race, 1.94 and 1.94 for family history of AAA, 4.45 and 5.07 for smoking, 0.50 and 0.52 for diabetes, and 1.60 and 1.66 for atherosclerotic diseases. The excess prevalence associated with smoking accounted for 75% of all AAAs of 4.0 cm or larger in the total population of 126 196. Associations for AAA of 3.0 to 3.9 cm were similar but tended to be somewhat weaker. CONCLUSIONS: Our findings confirm our previous cohort findings. Age, smoking, family history of AAA, and atherosclerotic diseases remained the principal positive associations with AAA, and female sex, diabetes, and black race remained the principal negative associations.

Aged↗

Yield of repeated screening for abdominal aortic aneurysm after a 4-year interval. Aneurysm Detection and Management Veterans Affairs Cooperative Study Investigators.

BACKGROUND: Little is known about the rate at which new abdominal aortic aneurysms (AAAs) develop or whether screening older men for AAA, if undertaken, should be limited to once in a lifetime or repeated at intervals. METHODS: A large population of veterans, aged 50 through 79 years, completed a questionnaire and underwent ultrasound screening for AAA. Of these, 5151 without AAA on the initial ultrasound (defined as infrarenal aortic diameter of 3.0 cm or larger) were selected randomly to be invited for a second ultrasound screening after an interval of 4 years. Local records and national databases were searched to identify deaths and AAA diagnoses made during the study interval in subjects who did not attend the rescreening. RESULTS: Of the 5151 subjects selected for a second screening, 598 (11.6%) had died (none due to AAA), and 20 (0.4%) had an interim diagnosis of AAA. A second screening was performed on 2622 (50.9%), of whom 58 (2.2%; 95% confidence interval, 1.6%-2.8%) had new AAA. Three new AAAs were 4.0 to 4.9 cm, 10 were 3.5 to 3.9 cm, and 45 were 3.0 to 3.4 cm. Independent predictors of new AAA at the second screening included current smoker (odds ratio, 3.09; 95% confidence, 1.74-5.50), coronary artery disease (odds ratio, 1.81; 95% confidence interval, 1.07-3.07), and, in a separate model using a composite variable, any atherosclerosis (odds ratio, 1.97; 95% confidence interval, 1.16-3.35). Adding the interim and rescreening diagnosis rates suggests a 4-year incidence rate of 2.6%. Rescreening only in subjects with infrarenal aortic diameter of 2.5 cm or greater on the initial ultrasound would have missed more than two thirds of the new AAAs. CONCLUSIONS: A second screening is of little practical value after 4 years, mainly because the AAAs detected are small. However, the incidence that we observed suggests that a second screening after longer intervals (ie, more than 8 years) may provide yields similar to those seen in initial screening and therefore warrants further study.

Aged↗

Etiologic factors in progression of carotid stenosis: a 10-year study in 905 patients.

PURPOSE: The purpose of this study was to determine the etiologic factors in the progression of carotid stenosis. METHODS: We performed prospective serial duplex scan surveillance of 1470 carotid arteries in 905 asymptomatic patients during a 10-year period, with an average follow-up interval of 29 months and an average of 3.0 scans per carotid artery. Vascular laboratory and hospital records were used to collect risk factor information. The data were analyzed with proportional hazards modeling. RESULTS: We examined several demographic, clinical, and laboratory risk factors that were chosen because of their potential relevance to atherosclerotic disease. These factors were analyzed with univariate proportional hazards modeling, in which time to progression of stenosis was the outcome variable. The six significant predictors (P <.05) were age, sex, systolic pressure, pulse pressure (systolic pressure - diastolic pressure), total cholesterol, and high-density lipoprotein (HDL). All, except HDL, were positive predictors of time to disease progression. With multivariate modeling, only pulse pressure and HDL remained as significant independent predictors of stenosis progression. The risk ratio for a 10-mm Hg rise in pulse pressure was 1.12, and the risk ratio for a 10-mg/dL decrease in HDL was 1.20. CONCLUSION: In this large cohort of patients who were followed prospectively for carotid stenosis, pulse pressure and HDL were found to be the key risk factors for carotid stenosis progression. The fact that pulse pressure superseded systolic pressure in multivariate modeling may shed light on the biology of carotid plaque progression. Further, our identification of these modifiable risk factors may help in the design of therapeutic trials for the prevention of progression of carotid atherosclerosis.

Age Factors↗

Endovascular treatment of iliac limb stenoses or occlusions in 31 patients treated with the ancure endograft.

PURPOSE: The authors report their experience with treatment of iliac limb complications in patients treated with the Ancure endograft with Wallstents to provide additional support and thrombolysis when needed. MATERIALS AND METHODS: From February 1996 to October 1999, 88 patients were treated for abdominal aortic aneurysm with use of the Ancure endograft. Of the 88 devices used, 20 were tube grafts and the remaining 68 devices had a total of 130 iliac limbs (bifurcated, n = 62; aortoiliac, n = 6). After graft deployment, all patients underwent intraoperative aortography; since July 1997, intravascular ultrasound (IVUS) has also been used. RESULTS: Thirty-one patients (46%) required treatment of 47 (36%) limbs with Wallstents. Graft narrowing was observed in 41 limbs (27 patients) with IVUS immediately after graft deployment. All were successfully treated with placement of Wallstents. Before routine use of intraoperative IVUS, three patients presented between 2 and 6 weeks postoperatively with iliac limb thrombosis. All three limbs were successfully treated with thrombolysis and Wallstent placement to correct the underlying iliac problem. Additionally, two contralateral limbs in these three patients were also noted to have stenosis and were treated with use of Wallstents. The last patient required placement of a Wallstent to treat stenosis of surgical anastomosis of the iliac limb of an aortoiliac endograft at 3 days. All Wallstent-reinforced Ancure endografts remained patent from 1 to 36 months (mean, 14 months). CONCLUSION: After placement of an Ancure bifurcated or aortoiliac endograft, iliac limb stenosis is easily detected with use of intraoperative IVUS. Such complications can be safely corrected with Wallstent placement. Postoperative limb occlusion at the authors' institution has been eliminated with such intervention.

Aortic Aneurysm, Abdominal↗

Endovascular repair of the abdominal aortic aneurysm with the ancure endograft: CT follow-up of perigraft flow and aneurysm size at 6 months.

PURPOSE: Perigraft flow--flow outside the graft lumen but contained within the abdominal aortic aneurysm (AAA)--is a potential complication after endovascular repair of AAA. Such flow may permit AAA growth and rupture. The purpose of this study is to evaluate with computed tomography (CT) the rate of spontaneous closure of perigraft flow and the effect of persistent flow on AAA diameter. MATERIALS AND METHODS: During a 30-month period, the authors evaluated all CT scans in 50 patients who underwent AAA repair using the Ancure endograft system. CT was performed at discharge, 6, 12, and 24 months, and at 3 months if there was perigraft flow at discharge. Scans were reviewed for the presence, size, and location of perigraft flow, and measurement of AAA diameter. Transcatheter embolization was performed on those patients with persistent leak at 6 months. RESULTS: Sixteen (32%) of 50 patients demonstrated perigraft flow on CT performed within 72 hours of placement. Resolution of perigraft flow by 6 months was found in nine (56%) of the 16 patients, in whom AAA size had decreased in five, had increased in none, and was unchanged in four. Seven patients had persistent leaks at 6-month CT; AAA size had decreased in one, had increased in one, and was unchanged in five. In 34 patients without leaks, AAA size had decreased in nine, had increased in one, and was unchanged on 24. There was no statistically significant difference for the relationship between resolution or persistence of perigraft flow and subsequent course of AAA diameter (P = .16). CONCLUSIONS: Although perigraft flow is frequently seen (32%) early after repair of AAA with the Ancure system, spontaneous resolution by 6 months occurs in 56% of cases. AAA size decreased in a larger percentage of patients in whom perigraft leak was absent or resolved by 6 months compared with those in whom perigraft leak persisted at 6 months.

Aged↗

Wall stress distribution on three-dimensionally reconstructed models of human abdominal aortic aneurysm.

PURPOSE: Abdominal aortic aneurysm (AAA) rupture is believed to occur when the mechanical stress acting on the wall exceeds the strength of the wall tissue. Therefore, knowledge of the stress distribution in an intact AAA wall could be useful in assessing its risk of rupture. We developed a methodology to noninvasively estimate the in vivo wall stress distribution for actual AAAs on a patient-to-patient basis. METHODS: Six patients with AAAs and one control patient with a nonaneurysmal aorta were the study subjects. Data from spiral computed tomography scans were used as a means of three-dimensionally reconstructing the in situ geometry of the intact AAAs and the control aorta. We used a nonlinear biomechanical model developed specifically for AAA wall tissue. By means of the finite element method, the stress distribution on the aortic wall of all subjects under systolic blood pressure was determined and studied. RESULTS: In all the AAA cases, the wall stress was complexly distributed, with distinct regions of high and low stress. Peak wall stress among AAA patients varied from 29 N/cm(2) to 45 N/cm(2) and was found on the posterior surface in all cases studied. The wall stress on the nonaneurysmal aorta in the control subject was relatively low and uniformly distributed, with a peak wall stress of 12 N/cm(2). AAA volume, rather than AAA diameter, was shown by means of statistical analysis to be a better indicator of high wall stresses and possibly rupture. CONCLUSION: The approach taken to estimate AAA wall stress distribution is completely noninvasive and does not require any additional involvement or expense by the AAA patient. We believe that this methodology may allow for the evaluation of an individual AAA's rupture risk on a more biophysically sound basis than the widely used 5-cm AAA diameter criterion.

Adult↗

Long-term fate of the aneurysmal sac after endoluminal exclusion of abdominal aortic aneurysms.

PURPOSE: Shrinkage of an abdominal aortic aneurysm (AAA) is the hallmark of successful endoluminal treatment. Our goal was to prospectively assess the midterm to long-term shrinkage of the AAA sac after endovascular repair. METHODS: A total of 123 patients with AAA underwent endoluminal treatment with the Ancure device at our institution between February 1996 and February 2000. At least a 1-year follow-up was available for 70 of the 123 patients. AAA sac size, presence of endoleaks, calcifications, and outcome data were collected on these patients at 6, 12, 24, and 36 months after repair and compared with the preoperative AAA size and characteristics. All endoleaks found at the 6-month follow-up visit were treated aggressively with embolotherapy. An AAA sac regression of 0.5 cm or more was considered the minimum measurable decrease. Regression of the sac diameter to 3.5 cm or less was considered a complete collapse of the sac. RESULTS: Successful endoluminal repair was accomplished in 119 of 123 patients. The mortality rate was 0.8% (1/123). There was a steady decrease in AAA sac size from baseline (5.56 +/- 0.1 cm), to 6 months (5.0 +/- 0.14 cm, P =.0006), to 12 months (4.65 +/- 0.13 cm, P =.04), and to 24 months (4.26 +/- 0.16 cm, P =.03). At 24 months, 74% (29/39) had a decrease in sac size of 0.5 cm or more, with 28% (11/39) complete collapse. Patients with initial endoleaks had the same likelihood of regression of sac size (> or = 0.5 cm) when compared with the group of patients with no endoleaks at the 24-month evaluation (64% vs 76%, P =.09). CONCLUSION: Endoluminal AAA repair resulted in a significant reduction in sac size that continues up to 2 years. Significant shrinkage occurs as early as 6 months after placement. The initial presence of endoleaks does not predict the lack of sac regression.

Aged↗

Is routine use of the intensive care unit after elective infrarenal abdominal aortic aneurysm repair necessary?

INTRODUCTION: Postoperative care after infrarenal abdominal aortic aneurysm (AAA) repair has traditionally involved admission to the intensive care unit (ICU). With the advent of endovascular AAA repair, the management of open procedures has received increased scrutiny. We recently modified our AAA clinical pathway to include selective use of the ICU. METHODS: Consecutive elective infrarenal AAA repairs performed by members of the vascular surgery division at a university medical center from 1994 to 1999 were analyzed retrospectively with a computerized database, the Medical Archival Retrieval System. Group I consisted of 245 patients who were treated in the ICU for 1 or more days, and Group II included 69 patients admitted directly to the floor. Ruptured, symptomatic, suprarenal, endovascular, and reoperative repairs were excluded. Outcome variables were compared over the 6-year period. RESULTS: Floor admissions increased over the study period with 0%, 0%, 3.3%, 16.3%, 48.6%, and 43.6% of patients admitted directly to the surgery ward from 1994 to 1999. The average ICU length of stay declined from 4.6 to 1.2 days, whereas the hospital length of stay decreased from 12.5 to 6.8 days from 1994 to 1999. The change in ICU use had no effect on death (2.4% in Group I vs 0% in Group II). Major and minor morbidity was comparable. Hospital charges were significantly lower for patients in Group II. CONCLUSION: A policy of selective utilization of the ICU after elective infrarenal AAA repair is safe. It can reduce resource use without a negative impact on the quality of care.

Aged↗

Is color-flow duplex a good diagnostic test for detection of isolated calf vein thrombosis in high-risk patients?

Color-flow duplex scanning (CDS) is a good diagnostic test for lower extremity proximal deep vein thrombosis (DVT). This report aims to evaluate the diagnostic accuracy of CDS in detecting isolated calf DVT in two in-hospital populations. A total of 166 patients had routine DVT testing with both CDS and venography: 99 total joint arthroplasty patients and 67 symptomatic in-hospital patients. Isolated calf DVT was noted in 34% of arthroplasty patients and 12% of symptomatic in-hospital patients. Peroneal DVT was most common. The sensitivity, specificity, positive predictive value, and negative predictive value (with 95% confidence interval [CI]) of CDS in detecting isolated calf DVT in the symptomatic in-hospital group was 39% (16%-62%), 98% (94%-99%), 88% (65%-99%), and 81% (71%-91%), respectively. In the arthroplasty patients these values were 13% (3%-23%), 92% (85%-99%), 60% (30%-90%), and 55% (45%-65%), respectively. CDS has a low sensitivity in detecting isolated calf DVT among hospitalized patients and cannot be deemed an effective tool for identifying clots limited to only one or two tibial vessels.

Arthroplasty, Replacement, Hip↗

Endovascular repair of an aortoduodenal fistula.

PURPOSE: To demonstrate the utility of endovascular stent-graft repair for the management of an unusual aortoduodenal fistula. METHODS AND RESULTS: A 23-year-old man with an aortoduodenal fistula secondary to tumor necrosis was treated with a Corvita endoluminal stent-graft after several failed surgical attempts to repair the defect. At 2-year follow-up, the patient was clinically and radiographically devoid of any evidence of occult stent-graft infection. CONCLUSIONS: This case illustrates the usefulness of endovascular repair for the treatment of a primary aortoduodenal fistula. Endovascular repair should be included in the armamentarium for the management of difficult aortoduodenal fistulas.

Adult↗