PubMed Health⌕ Search

Biomedical subjects

M S Sklansky

Publications and source records attributed to M S Sklansky.

23 records · Page 2Linked to original sources

Successful balloon dilation of an abdominal coarctation of the aorta in patient with presumed Takayasu's aortitis.

An 11-year-old male with a severe abdominal aortic coarctation, presumably secondary to aortitis, underwent successful percutaneous balloon dilation that resulted in near-complete relief of the obstruction. Intravascular ultrasound imaging showed a major endovascular tear immediately following dilation and satisfactorily excluded significant branch (superior mesenteric) artery compromise. Arterial remodeling was demonstrated with persistence of the gradient relief over a 12-month follow-up period.

Aorta, Abdominal↗

Atrioventricular situs concordance with atrioventricular alignment discordance: fetal and neonatal echocardiographic findings.

Fetal echocardiography can reliably assess visceroatrial situs, ventricular morphology, and atrioventricular and ventriculoarterial alignments. The echocardiographic findings of this case were consistent with visceroatrial situs solitus, atrioventricular alignment discordance, and ventriculoarterial alignment concordance. This arrangement is almost always associated with ventricular inversion, or L-looped ventricles, and has therefore been widely referred to as isolated ventricular inversion. Rarely, as in this report, the arrangement may be associated with D-looped ventricles. Fetal and neonatal echocardiography may distinguish situs concordance with atrioventricular alignment discordance from isolated ventricular inversion in situs solitus by the presence, in the former, of superior-inferior ventricles, an anterior right ventricle, and a tricuspid valve that is anterior and to the right of the pulmonary valve, consistent with D-looped ventricles.

Adult↗

Ambiguity and mistakes in the pediatric cardiology vernacular.

The pediatric cardiology vernacular is replete with ambiguous and erroneous terminology. This article discusses several examples in a plea to bring the accuracy and precision of the scientific method to the clinical pediatric cardiology vernacular.

Cardiology↗

Chest radiography and the evaluation of the neonate for congenital heart disease.

We assessed the utility of the chest film as a screening tool for term and preterm neonates with suspected structural heart disease. Three independent observers, blinded to patient diagnosis, retrospectively evaluated the initial chest film for each of 128 consecutive neonates with suspected heart disease (gestational age, 23-42 weeks; birth weight, 500-4,621 g) who had undergone both chest radiography and echocardiography. These evaluations were subsequently compared with the results of the respective echocardiograms, read by board-certified pediatric cardiologists blinded to the chest film and chest film interpretation. Kappa statistics demonstrated moderate correlation (0.42-0.48) among different observers in their interpretation of the chest films but poor correlation (0.15-0.34) between chest radiography and echocardiography. The chest film had a low sensitivity for structural heart disease (26-59%), with a negative predictive value of 46-52%. Among neonates less than 2 kg or younger than 35 weeks of gestation, the chest film had still lower sensitivity for detecting heart disease. Despite agreement among observers in chest film interpretation, the chest film does not function as a screening test for neonates with suspected heart disease, particularly in small or premature neonates. In neonates with suspected heart disease, echocardiography should be considered, even in patients with chest films that do not suggest congenital heart disease.

Diagnosis, Differential↗