Automated immunomagnetic separation and microarray detection of E. coli O157:H7 from poultry carcass rinse.

We describe the development and application of an electromagnetic flow cell and fluidics system for automated immunomagnetic separation (IMS) of Escherichia coli O157:H7 directly from poultry carcass rinse. We further describe the biochemical coupling of automated sample preparation with nucleic acid microarrays. Both the cell concentration system and microarray detection method did not require cell growth or enrichment from the poultry carcass rinse prior to IMS. Highly porous Ni foam was used to enhance the magnetic field gradient within the flow path, providing a mechanism for immobilizing immunomagnetic particles throughout the fluid rather than the tubing wall. A maximum of 32% recovery efficiency of non-pathogenic E. coli was achieved within the automated system with 6 s cell contact times using commercially available antibodies targeted against the O and K antigens. A 15-min protocol (from sample injection though elution) provided a cell recovery efficiency that was statistically similar to > I h batch captures. O157:H7 cells were reproducibly isolated directly from poultry carcass rinse with 39% recovery efficiency at 10(3) CFU ml(-1) inoculum. Direct plating of washed beads showed positive recovery of O157:H7 directly from poultry carcass rinse at an inoculum of 10 CFU ml(-1). Recovered beads were used for direct polymerase chain reaction (PCR) amplification and microarray detection, with a process-level detection limit (automated cell concentration though microarray detection) of < 10(3)CFU ml(-1) in poultry carcass rinse.

Animals↗

Rotating rod renewable microcolumns for automated, solid-phase DNA hybridization studies.

The development of a new temperature-controlled renewable microcolumn flow cell for solid-phase nucleic acid hybridization in an automated sequential injection system is described. The flow cell included a stepper motor-driven rotating rod with the working end cut to a 45 degrees angle. In one position, the end of the rod prevented passage of microbeads while allowing fluid flow; rotation of the rod by 180 degrees releases the beads. This system was used to rapidly test many hybridization and elution protocols to examine the temperature and solution conditions required for sequence-specific nucleic acid hybridization. Target nucleic acids labeled with a near-infrared fluorescent dye were detected immediately postcolumn during all column perfusion and elution steps using a flow-through fluorescence detector. Temperature control of the column and the presence of Triton X-100 surfactant were critical for specific hybridization. Perfusion of the column with complementary oligonucleotide (200 microL, 10 nM) resulted in hybridization with 8% of the DNA binding sites on the microbeads with a solution residence time of less than 1 s and a total sample perfusion time of 40 s. The use of the renewable column system for detection of an unlabeled PCR product in a sandwich assay was also demonstrated.

DNA↗