Future trends in diagnosis using laboratory-on-a-chip technologies.

There has been an enormous growth in the development of biotechnological applications, where advances in the techniques of microelectronic fabrication and the technologies of miniaturization and integration in semiconductor industries are being applied to the production of Laboratory-on-a-Chip devices. The aim of this development is to create devices that will perform the same processes that are currently carried out in the laboratory in reduced timescales, at a lower cost, requiring less reagents, and with a greater resolution of detection and specificity. The expectations of this Laboratory-on-a-Chip revolution is that this technology will facilitate rapid advances in gene discovery, genetic mapping and gene expression with broader applications ranging from infectious diseases and cancer diagnostics to food quality and environmental testing. A review of the current state of development in this field reveals the scale of the ongoing revolution and serves to highlight the advances that can be perceived in the development of Laboratory-on-a-Chip technologies. Since miniaturization can be applied to such a wide range of laboratory processes, some of the sub-units that can be used as building blocks in these devices are described, with a brief description of some of the fabrication processes that can be used to create them.

Animals↗

The dielectrophoresis enrichment of CD34+ cells from peripheral blood stem cell harvests.

There is considerable interest in isolating the CD34+ cell population from leukaemic patients undergoing peripheral blood stem cell harvests. The techniques currently available make use of antibodies specific to the CD34+ surface markers. However, all of these techniques involve disturbance of the cell surface, are time-consuming and relatively expensive. In this study, we have used dielectrophoresis, which does not rely on the presence of cell-specific markers, to separate CD34+ cells from peripheral blood stem cell harvest samples containing an untreated natural mixed cell population. The separation is achieved by exploiting differences in the inherent dielectric properties of the various cell types. Samples obtained from peripheral blood stem cell harvests were resuspended in medium with a conductivity of less than 50 microS/cm and introduced into the dielectrophoretic separation chamber. Alternating field frequencies, from 500 kHz to 5 kHz, were used to collect cell fractions which were analysed by FACS, using a CD34-specific antibody, to quantify the CD34+ population within the fractions. On average a nearly five-fold increase in the frequency of the CD34+ cell population was observed in the fractions collected within the 50-10 kHz range. For this dielectrophoretic separation technique to be suitable in harvesting CD34+ cells for transplantation, it is important to demonstrate that the cells remain viable after the separation process. Cells obtained from each fraction grew when plated in colony assay cultures, GM-CFU and BFU-E, demonstrating that the cells remain normal, viable and capable of colony formation when cultured for 2 weeks. The number of colonies formed correlated with the percentage of CD34+ cells in each fraction. The dielectrophoretic separation technique is simple to operate, the separation is fast, the procedure non-invasive and although not tested has the potential to be incorporated as a batch-wise online facility with the standard harvesting equipment to increase the yield and speed of CD34+ cells in the PBSC harvest.

Antigens, CD34↗

Dielectrophoretic separation and enrichment of CD34+ cell subpopulation from bone marrow and peripheral blood stem cells.

Dielectrophoresis has been used to enrich selected cell subpopulations in a mixed cell population by exploiting differential dielectric properties. Six-fold enrichment of stem cells expressing the CD34+ antigen has been achieved for bone marrow samples and peripheral blood, without the requirement for initial chemical treatment associated with immunoadsorption techniques.

Antigens, CD↗

Separation of viable and non-viable yeast using dielectrophoresis.

Dielectrophoresis, the movement of particles in non-uniform AC electric fields, was used to rapidly separate viable and non-viable yeast cells with good efficiency. Known mixtures of viable and heat-treated cells of Saccharomyces cerevisiae were separated and selectively isolated using positive and negative dielectrophoretic forces generated by microelectrodes in a small chamber. Good correlations with the initial known relative compositions were obtained by direct microscopic counting of cells at the electrodes after initial dielectrophoretic separation (r = 0.995), from methylene blue staining (r = 0.992) and by optical absorption measurements (r = 0.980) of the effluent after selectively flushing out the viable and non-viable cells from the chamber. Through measurement of cell viability by staining with methylene blue and plate counts, for an initial suspension of approx. 1.4 x 10(7) cells per ml containing 60% non-viable cells, the dielectrophoretically separated non-viable fraction contained 3% viable cells and the viable fraction 8% dead cells. The separation efficiency is increased by dilution of the initial suspension or by repeat operation(s). Cell viability was not affected by the separation procedure.