PubMed Health⌕ Search

Biomedical subjects

M Sabaté

Publications and source records attributed to M Sabaté.

64 records · Page 4Linked to original sources

Obstructive and restrictive pulmonary dysfunction increases disability in Parkinson disease.

OBJECTIVE: The purpose of this study was to determine in Parkinson disease the impact of pulmonary dysfunction on daily living activities (DLA). PATIENTS: Extrapyramidal motor impairment, pulmonary dysfunction, and DLA disabilities were studied in 58 Parkinson patients consecutively enrolled in a rehabilitation service at a university hospital. MAIN OUTCOME MEASURES: Extrapyramidal motor impairments were assessed by the Unified Parkinson's Disease Rating Scale (UPDRS) and the DLA disabilities by the UPDRS, Hoehn-Yahr, and Schwab-England scales. The pulmonary dysfunctions were assessed by spirometry with flow-volume loops, body plethysmography with lung volumes computation, and maximal inspiratory and expiratory static mouth pressures. RESULTS: Parkinson patients showed important modifications of pulmonary function with a decrease in forced vital capacity, forced expiratory volume in the first minute, and arterial PO2, and an increase in residual volume and total airway resistance (RAW). In addition, they showed a high incidence of airway ventilatory obstructions and restrictive dysfunction. The impact of lung disease on daily living activities in Parkinson disease patients was higher in subjects with restrictive pulmonary dysfunctions (Schwab-England test and turning in bed and adjusting bedclothes, walking, falling, and freezing when walking items of UPDRS) and airway obstructions (handling utensils, dressing and hygiene items of UPDRS). CONCLUSIONS: Airway obstructions or restrictive pulmonary dysfunctions present a high prevalence in Parkinson disease, contributing as a main factor for DLA dysfunctions. The evaluation and rehabilitation of respiratory disturbances should be systematically included in the management of these patients.

Activities of Daily Living↗

[The mechanism producing nausea during ventriculography performed with ioxaglate: the implications of a randomized study].

INTRODUCTION: The mechanism of ioxaglate-induced nausea has not been fully elucidated. Recent studies have demonstrated that serotonin is one of the principal neurotransmitters of emesis in humans. On the other hand, the greater capacity of ioxaglate to stimulate vomiting has been ascribed to its great ability to inhibit cholinesterase. METHODS: To determine if oral metoclopramide (a serotonin receptor-blocker) is effective in the prophylaxis of ioxaglate-induced nausea during left ventriculography, 637 of 711 consecutive eligible patients were included in a prospective study. Patients were randomized to receive, 60-90 minutes before the procedure, either diazepam 10 mg p.o. (control group [n = 315]) or diazepam 10 mg p.o. plus metoclopramide 10 mg p.o. (metoclopramide group [n = 322]). RESULTS: The two randomized groups were similar in relation to baseline clinical and hemodynamic characteristics. Nausea was documented in 103 patients (16.1%) with similar incidence in the two groups (control group: 16.8%, metoclopramide group: 15.5%; p = NS). Nausea duration was also similar (56 +/- 63 s vs 52 +/- 63 s; p = NS). When patients with and without nausea were compared, the following variables showed a significant difference between the two groups: male gender (86% vs 76%; p < 0.05), age (53 +/- 10 yrs vs 56 +/- 9 yrs; p < 0.05) and body surface area (1.84 +/- 0.2 m2 vs 1.78 +/- 0.1 m2; p < 0.01). Stepwise multiple regression analysis identified low age (p = 0.02) and male gender (p = 0.06) as independent predictors of nausea. The incidence of nausea was 24% in males < or = 45 yrs vs 9% in females > 45 yrs (p < 0.05). CONCLUSIONS: Prophylaxis with oral metoclopramide did not reduce the incidence of ioxaglate-induced nausea during left ventriculography. This data do not support a role of serotonin in the production of nausea by ioxaglate. Low age an male gender are independent predictors of nausea apparition during left ventriculography. A cholinergic mechanism is probably involved in the capacity of ioxaglate to stimulate vomiting.

Administration, Oral↗

[In vitro sensitivity to 5-fluorocytosine and amphotericin B of yeasts of the Candida genus isolated in Barcelona].

In 200 strains of Candida sp, 38.5% were found to have intermediate sensitivity or to be resistant to amphotericin B and/or 5-fluorocytosine by the agar diffusion method. When the minimal inhibitory concentrations of these strains were measured, only 7.8% were resistant to amphotericin B and 2.8% to 5-fluorocytosine. The species with the highest levels of resistance were C. parapsilosis, C. tropicalis and Torulopsis glabrata. Candida albicans did not show resistance to 5-fluorocytosine.

Amphotericin B↗

Endovascular brachytherapy in coronary arteries: the Rotterdam experience.

PURPOSE: The use of endovascular coronary brachytherapy to prevent restenosis following percutaneous transluminal coronary angioplasty (PTCA) began in April 1997 at the Department of Interventional Cardiology of the Thoraxcenter at the University Hospital of Rotterdam. This article reviews the more than 250 patients that have been treated so far. METHODS AND MATERIALS: The Beta-Cath System (Novoste), a manual, hydraulic afterloader with 12 90Sr seeds, was used in the Beta Energy Restenosis Trial (BERT-1.5, n = 31), for compassionate use (n = 25), in the Beta-Cath System trial (n = 27) and in the Beta Radiation in Europe (BRIE, n = 14). Since the Beta-Cath System has been commercialized in Europe, 57 patients have been treated and registered in RENO (Registry Novoste). In the Proliferation Reduction with Vascular Energy Trial (PREVENT), 37 patients were randomized using the Guidant-Nucletron remote control afterloader with a 32P source wire and a centering catheter. Radioactive 32P coated stents have been implanted in 102 patients. In the Isostent Restenosis Intervention Study 1 (IRIS 1), 26 patients received a stent with an activity of 0.75-1.5 microCi, and in the IRIS 2 (European 32P dose response trial), 40 patients were treated with an activity of 6-12 microCi. In two consecutive pilot trials, radioactive stents with non-radioactive ends (cold-end stents) and with ends containing higher levels of activity (hot-end stents) were implanted in 21 and 17 patients, respectively. RESULTS: In the BERT-1.5 trial, the radiation dose, prescribed at 2 mm from the source train (non-centered), was 12 Gy (10 patients), 14 Gy (10 patients) and 16 Gy (11 patients). At 6-month follow-up, 8 out of 28 (29%) patients developed restenosis. The target lesion revascularization rate (TLR) was 7 out of 30 (23%) at 6 months and 8 out of 30 (27%) at 1 year. Two patients presented with late thrombosis in the first year. For compassionate use patients, a restenosis rate (RR) of 53% was observed. In the PREVENT trial, 34 of 37 patients underwent an angiographic 6-month follow-up. The doses prescribed at 0.5 mm depth into the vessel wall were 0 Gy (8), 28 Gy (9), 35 Gy (11) and 42 Gy (8). TLR was 14% in the irradiated patients and 25% in the placebo group. One patient developed late thrombosis. In the IRIS 1 trial, 23 patients showed an RR of 17% (in-stent). In the IRIS 2 trial, in-stent restenosis was not seen in 36 patients at 6-month follow-up. However, a high RR (44%) was observed at the stent edges. CONCLUSIONS: The integration of vascular brachytherapy in the catheterization laboratory is feasible and the different treatment techniques that are used are safe. Problems, such as edge restenosis and late thrombotic occlusion, have been identified as limiting factors of this technique. Solutions have been suggested and will be tested in future trials.

Angioplasty, Balloon, Coronary↗

Predictors of failure in direct stenting in the real world.

INTRODUCTION: Stent implantation without predilation simplifies a large proportion of coronary intervention procedures, with a significant reduction in costs and procedure time. OBJECTIVES: To determine the variables associated with a higher probability of failure in direct stent implantation in daily practice in a wide range of clinical contexts and types of lesions. POPULATION AND METHODS: Over a period of 28 months, direct implantation of 931 stents was attempted in our Center (811 patients, 83% male, mean age 62 +/- 12 years; 1.1 stent per patient). In 59 patients (7.3%), balloon predilation was necessary, and the factors associated with direct implant failure were determined. RESULTS: The vessels treated were: anterior descending (373 lesions: 40.1%), right coronary artery (306 lesions: 32.9%, circumflex (210 lesions: 22.6%), saphenous vein (35 lesions: 3.8%), left main (5 lesions: 0.4%) and internal mammary artery (2 lesions: 0.2%). 54% of the lesions were of type B2/C (ACC/AHA classification). The characteristics significantly associated with, or with statistical tendency towards, a lower success rate in direct stent implantation were: Lesion in the circumflex (11% vs. 5.5%, p = 0.012); reference vessel diameter less than 3.0 mm (9.8% vs. 6.2%, p = 0.097); age over 65 years (8.5% vs. 4.5%, p = 0.017); left main disease, irrespective of the vessel treated (23.5%% vs. 6.5%, p = 0.023); B2/C lesion (7.8%, vs. 4.8%, p = 0.086); calcification (9.9% vs. 4.9%, p = 0.012); vessel angulation greater than 45 degrees (9.9% vs. 4.9%, p = 0.009); and Express stent implant (19.6% vs. 6.0%, p < 0.001). On multivariate analysis, independent predictors of failure in direct stent implantation were: left main lesion (RR 6.6; 95% CI 1.73-24.93; p = 0.013), presence of calcium (RR 1.9; 95% CI 1.02-3.37; p = 0.049), vessel curvature (RR 2.0; 95% CI 1.13-3.64; p = 0.018), reference vessel diameter less than 3 mm (RR 2.2; 95% CI 1.15-4.32; p = 0.023), lesion type B2/C (RR 1.9; 95% CI 1.0-3.52; p = 0.044) and Express stent (RR 2.7; 95% CI 1.07-6.79; p = 0.05). CONCLUSION: In a large and heterogeneous series of patients, direct stenting was not possible in 7.3% of cases, which required balloon predilation. Certain clinical and angiographic features can predict when this is more like to occur.

Equipment Failure↗

[Aberrant renal papilla. 2 new case reports. Diagnostic considerations].

Another two cases of aberrant renal papilla are described. These had been diagnosed following an IVP procedure and corroborated by ultrasound. One patient had presented with prostatism and the other had consulted for episodes of renal colic. Because a differential diagnosis is mandatory to distinguish this uncommon condition from other filling defects of the renal pelvis and particularly from false aberrant renal papilla, we were prompted to report on these two cases.

Diagnosis, Differential↗