PubMed Health⌕ Search

Biomedical subjects

M Schönauer

Publications and source records attributed to M Schönauer.

9 recordsLinked to original sources

Intracranial pressure patterns after endoscopic third ventriculostomy. Preliminary experience.

BACKGROUND: Endoscopic Third Ventriculostomy (ETV) has become the treatment of choice for non-communicating hydrocephalus as it is able to couple high success rate (60-80%) with rare complications (about 5%). Nevertheless, which is the best postoperative care standard and whether or not it is possible to predict the success of the procedure is still discussed. Traditional neuro-imaging techniques show several limitations in the early postoperative period. Indeed, a decrease of the ventricular size is often minimal and not visible before three weeks, while, MRI visualization of a flow void signal through the third ventricle floor, seems to have a significant incidence of false positives. The use of postoperative ICP measurement after ETV has been suggested as a valid monitoring method, mostly in the early postoperative period. In previously unpublished data the authors observed the existence of different ICP patterns following ETV. This finding prompted the authors to search for a relationship among ICP patterns, stoma functioning and prediction of success. METHOD: At our institution 26 consecutive patients affected by obstructive triventricular hydrocephalus underwent ETV. Among them there were 11 primitive aqueductal stenosis (AS), 5 shunt malfunctions, 2 third ventricle mass, 3 intraventricular cysts, and 5 patients with different lesions (1 quadrigeminal cistern arachnoidal cyst, 1 pineal region mass, 2 tectal tumours, and 1 supracerebellar abscess) compressing the aqueduct of Sylvius from outside named " ab estrinseco" aqueductal stenosis. All patients underwent postoperative Intra Cranial Pressure (ICP) monitoring by means of a ventricular catheter. FINDINGS: Transient ICP rises of any grade, mostly responsive to periodical liquoral subtractions, occurred shortly after ETV in as many as 50% of our patients. No major complications occurred. The effect of ETV on ICP trend was found to be variable among groups of patients thus identifying different ICP patterns. Patients with ab estrinseco Sylvian aqueduct compression showed the best effect on ICP, whilst, patients with intraventricular mass lesions causing triventricular hydrocephalus and shunt-dependent patients, revealed a clear trend to develop a more severe intracranial hypertension after ETV. CONCLUSIONS: Patients with shunt malfunction and patients with intraventricular mass lesions, showing a more pronounced trend to develop severe intracranial hypertension after ETV, should always be considered for postoperative ICP monitoring in order to detect and, eventually, treat any ICP rises which may occur. Unfortunately, it is still difficult to assign a predictive value to the different postoperative ICP patterns. The authors encourage postoperative ICP monitoring in all patients in order to define all the possible ICP patterns following ETV.

Adolescent↗

High resolution multi-temperature sensors for biomedical application.

A temperature sensor array was designed in order to study local temperature variations and temperature gradients in biological samples. The sensor probe was inserted in the optical cortex of rabbits in order to study temperature changes during normal brain activity as well as under artificial ventilation conditions. Temperature sensitive areas of 0.14 mm x 0.1 mm are arranged in a row with interdistances of 0.4 mm yielding high spatial resolution. A temperature resolution of 0.1 mK and a 90% response time of maximum 3 milliseconds was obtained utilizing the high temperature dependence of 2%/K of the conductivity of vacuum evaporated germanium films. The sensor is passivated by a 1 micron thick PECVD-silicon nitride layer and can be placed on glass-, alumina- and polymer substrates. For brain tissue studies, in order to minimize tissue damage the temperature sensors were placed on a 0.1 mm thick needle-shaped glass substrate. A sensor element mounted on a glass substrate and immersed in water showed a self heating of less than 5 mK due to the applied measurement current of 2.1 microA.

Animals↗

Space occupying contusions of cerebral lobes after closed brain injury: considerations about 51 cases.

Fifty one cases of space occupying contusions of the brain have been treated between 1967 and 1974. These represented 2.4% of all head injuries. Forty four were surgically treated and only clinically. The total mortality was 50.9% being 91.4% in patients above 50 years of age and 41% in patients below 50. In 66.6% of patients the lesions were localized in the temporal lobes, and two patients had localized cerebellar contusions. Surgery was performed in 44 patients. There were 13 craniectomies and 31 craniotomies. The operative mortality was 54.5%. Mortality was 65.2% in patients operated on within 24 hours of injury, and 12.5% in those operated on more than 72 hours after trauma. Twenty five patients (20 treated surgically and 5 managed clinically) were examined one year after injury. Eighty four percent were in either good or excellent condition.

Adolescent↗