PubMed Health⌕ Search

Biomedical subjects

M Scheida

Publications and source records attributed to M Scheida.

2 recordsLinked to original sources

Validity of new immunological human fecal hemoglobin and albumin tests in detecting colorectal neoplasms--an endoscopy-controlled study.

BACKGROUND: Screening for occult blood by means of guaiac tests has an unsatisfactory sensitivity for the detection of colorectal neoplasms. To increase sensitivity and specificity the immunological determination of human hemoglobin and albumin in feces has been developed. The validity of analyzing only two samples from one bowel movement of either test is not known. METHODS: An immunological determination of human fecal hemoglobin and albumin using luminescence immunoassays (LIA) was performed in 739 patients with gastrointestinal complaints before scheduled colonoscopy. Each patient collected two 1 ml samples from one stool. There were no dietary restrictions. RESULTS: The sensitivity for detecting colorectal carcinomas was 95.3% (95% confidence interval 84.2-99.4%) with hemoglobin and 67.4% (95% confidence interval 51.2-80.9%) with albumin. The sensitivity for detecting large adenomatous polyps was 62.9% (95% confidence interval 50.5-74.1%) with hemoglobin and 32.9% (95% confidence interval 22.1-45.1%) with albumin. The specificity was 97% for hemoglobin, 96% for albumin and 94% for the combined test. CONCLUSIONS: The immunological determination of fecal hemoglobin is superior to albumin and has a better sensitivity for the detection of colorectal neoplasms than that reported for guaiac tests, even if two samples from one bowel movement are examined. The immunological determination of fecal hemoglobin should therefore be evaluated for use in colorectal cancer screening.

Colonoscopy↗

Solid-phase competitive luminescence immunoassay for lysozyme in faeces.

We have developed a new simple solid-phase luminescence immunoassay (LIA) for the determination of faecal lysozyme. The assay utilises a polyclonal capture antibody coated to polystyrene beads and acridinium ester-labelled human lysozyme as tracer. Samples are incubated with polystyrene beads and tracer overnight at 4 degrees C. After a thorough washing step, emitted light is measured by an automated luminometer for 2 seconds. The standard curve uses five standards ranging from 0.025 to 6.4 mg/l. The method has a sensitivity of 0.02 mg/l. Dilution recoveries for three samples were 88, 104 and 108%. Intraassay coefficients of variation (CV, n = 24) were 10.1% and 11.7% for a healthy control and a patient sample; interassay CV (n = 16) were 6.7% and 13.1% for the same healthy control but another patient sample. The normal range of faecal lysozyme in 80 healthy controls was found to be 0.02-1 mg/l (97.5 percentile) with a median of 0.28 mg/l. Fifty-three patients with Crohn's disease had faecal lysozyme values ranging from 0.16 to 100.7 mg/l with a median of 1.75 mg/l, and 30 patients with ulcerative colitis showed levels between 0.09 and 118 mg/l with a median of 1.11 mg/l. The assay has proved useful for differentiating healthy individuals from those with inflammatory bowel disease and might be a valuable tool for diagnosing or evaluating inflammatory bowel disease.

Adolescent↗