Serial immunoreactive erythropoietin levels in autologous blood donors.

The variations in plasma erythropoietin (EPO) concentration during preoperative deposit of autologous blood were studied in 12 patients (8 men, 4 women). Four donations were scheduled at weekly intervals. A predonation hemoglobin concentration of 11 g per dL (110 g/L) was required. Hemoglobin concentration decreased from 14.3 +/- 1.1 g per dL (143 +/- 11 g/L) (mean +/- SD) before the first donation to 11.7 +/- 0.7 g per dL (117 +/- 7 g/L) on Day 22 (p less than or equal to 0.0001). Reticulocyte counts increased from a median of 31,800 (range, 4900-95,000) per microL (median, 32 x 10(9)/L [range, 5-95 x 10(9)/L]) to 93,800 (16,800-194,900) per microL (median, 94 x 10(9)/L [range, 17-195 x 10(9)/L]) on Day 28 (p less than or equal to 0.01). Plasma EPO concentration was 17.8 +/- 5.1 mU per mL prior to the first donation and displayed a small and transient peak after each donation. A sustained elevation followed each peak. Although plasma EPO concentration differed significantly from the baseline value after the first donation, only the peak concentrations after the second (35.5 +/- 15.5 mU/mL), third (38.0 +/- 14.5 mU/mL), and fourth (36.1 +/- 11.0 mU/mL) donations exceeded the normal range. The moderate, biphasic increase in plasma EPO concentration and the moderate increase in erythropoiesis suggest two strategies in autologous blood donation that should be investigated with respect to efficiency and safety: 1) more aggressive donation schemes, which reduce donation intervals and/or the minimum hemoglobin concentration and 2) the administration of recombinant human EPO.

Adult

[Intra- and postoperative autotransfusion in hip joint surgery. Effectiveness, bacteriology].

The efficiency of intraoperative and postoperative autotransfusion with a cell separator, the elimination of a cephalosporin administered for prophylaxis of infection and bacterial contamination of the blood retransfused were studied in 56 patients undergoing hip arthroplasty (n = 33) or exchange reoperation of hip arthroplasty (n = 23). Intraoperatively only a limited amount of the lost erythrocytes could be retransfused: in hip arthroplasty 250 ml (median) packed red cells of 700 ml blood loss, in exchange reoperation 750 ml of 2200 ml. Postoperative autotransfusion was more effective: during the autotransfusion period (until 6 h after the beginning of the operation) 375 ml of 650 ml and 500 ml of 830 ml could be retransfused in the two groups. Cefuroxime was eliminated effectively from the autologous blood by the cell washing process, usually below the limit of detection. In the washed autologous red blood cells of 3 patients (= 5.4%) bacterial contamination could be demonstrated in low titres (less than or equal to 10/ml). No clinical signs of bacteremia were observed during retransfusion. Postoperative autotransfusion contributes considerably to the total amount of autologous erythrocytes retransfused. Bacterial contamination of the processed autologous blood is infrequent and probably without clinical significance.

Adult

[Preoperative autologous blood deposit and liquid storage for replacement arthroplasty].

Transfusion of homologous blood components is associated with immunological (incompatibility, alloimmunization, immunosuppression) and infectious risks (hepatitis, cytomegalovirus, HIV and other agents). Endoprosthetic surgery of the hip and knee frequently requires transfusion. Preoperative deposit of autologous blood can reduce homologous transfusion requirements. The simplest method is liquid storage of whole blood. In order to re-examine the efficiency of our present scheme of preoperative deposit, we studied patients scheduled for endoprosthetic surgery with respect to the amount of blood deposited, stimulation of erythropoiesis, and homologous blood requirements at the time of operation. PATIENTS AND METHODS. Sixty-seven consecutive patients (33 men, 34 women) scheduled for endoprosthetic replacement of hip or knee or for revision arthroplasty of the hip were studied. Patients with anemia, coagulopathies, coronary heart disease, severe obstructive or restrictive pulmonary disease, cerebral sclerosis, syncopes and seizures were excluded from preoperative deposit. Patients deposited 450 ml at weekly intervals, with occasionally slightly higher or lower volumes. A patient was temporarily deferred when the hemoglobin concentration prior to donation fell below 11 g/dl. Blood was collected in CPDA-1 buffer. The aim was a deposit of three units. In patients undergoing exchange reoperation of a total hip arthroplasty, intra- and postoperative autotransfusion with a cell separator was employed in addition to preoperative donation. RESULTS. The age of the patients ranged from 43 to 83 years (mean +/- SD: 61.2 +/- 9.1). The differences between men and women with respect to height (172.9 +/- 6.8 vs 160.6 +/- 7.4 cm; p less than or equal to 0.001), weight (75.7 +/- 11.2 vs 69.1 +/- 11.0 kg; p less than or equal to 0.05), calculated blood volume (p less than or equal to 0.001), and erythrocyte volume prior to donation (p less than or equal to 0.001) were significant. A total of 185 units was deposited. Men donated 1350 (450-1970) ml blood (median, range) and women 1260 (340-1450) ml (p less than or equal to 0.01). Hemoglobin concentrations decreased significantly from an average of 14.7 g/dl in men and 13.8 g/dl in women prior to donation to 13.4 g/dl and 12.3 g/dl preoperatively (p less than or equal to 0.0001 for both groups). The donation was not associated with serious complications. For 4 patients the scheduled operation was deferred for a longer term. Forty-six patients (23 men, 23 women) underwent total hip arthroplasty, 12 (4 men, 8 women) exchange of total hip arthroplasty, and 5 (3 men, 2 women) endoprosthetic knee surgery. In total hip arthroplasty men required 0 to 500 ml homologous packed red cells (median=0), women 0 to 1250 ml (median=0;p less than or equal to 0.05). Thirty-nine (69.6%) of the patients, 19 (82.6%) men and 13 (56.5%) women, did not require homologous transfusion.(ABSTRACT TRUNCATED AT 400 WORDS)