Coronary restenosis after implantation of drug-eluting stents.

Randomized trials comparing drug-eluting stents (DES) with bare-metal stents have shown that the former significantly reduce the incidence of angiographic and clinical restenosis into an unprecedented low, one-digit, range. However, post-DES restenosis is not zero. Next to incomplete coverage with DES of the vessel segment injured by balloon angioplasty, factors such as stent underexpansion, stent overexpansion, and nonuniform distribution of stent struts have been associated with post-DES restenosis. Current evidence suggests that inadequate, though predominantly focal, delivery of the antiproliferative agent (sirolimus or paclitaxel) into the vessel wall is likely the common cause of post-DES restenosis. There is no consensus at present on how to treat post-DES restenosis. Long-term results reported to date on small numbers of patients undergoing interventional treatment for post-DES restenosis appear to be worse than outcomes observed after the index intervention, regardless of whether another DES was implanted or not, and warrant further study.

Angioplasty, Balloon, Coronary↗

[Twist-guided thread control: a technique for faster and atraumatic continuous sutures].

A simple technique by twisting the thread in clockwise or counter clockwise direction before tightening the suture can help to produce a regular vascular suture line. In a blinded experiment with 60 vascular anastomosis it was proved that the time needed for suture can be reduced by 15%, and that traumatic touch with surgical instruments can be diminished by 63%.

Anastomosis, Surgical↗

Balloon-protected carotid artery stenting: relationship of periprocedural neurological complications with the size of particulate debris.

BACKGROUND: Carotid artery stenting (CAS) has been advocated as an alternative to endarterectomy. To prevent cerebral atheroembolism during CAS, distal balloon occlusion of the target artery increasingly is employed during the procedure. A correlation of the size of captured particles with the incidence of periprocedural neurological complications (PNCs) has not been attempted. METHODS AND RESULTS: In a 4-center, phase-1 trial, 54 patients (46 men; age, 69+/-8 years) underwent 58 CAS procedures using the PercuSurge GuardWire system for distal protection. Aspirated debris was sent for histological/cytological analysis. Stent placement was successful in all cases. Mean balloon occlusion time was 10.4+/-4.0 minutes (range, 3.0 to 22.0 minutes). Three patients (5.2%) experienced PNCs: 1 prolonged reversible ischemic neurological deficit that resolved in </=48 hours, 1 stroke, and 1 transient ischemic attack. Relevant particles (those with an area >/=10 000 micrometer(2)) were found in 48 aspirates (83%). The median number of particles, their maximum diameter, and their maximum area were all significantly higher in the aspirates obtained during procedures associated with PNCs than in aspirates obtained during procedures not associated with PNCs. However, pronounced overlap in the distributions (PNCs versus no PNCs) of the number and maximum diameter of particles precluded any predictive inferences. In contrast, a maximum particle area >800 000 micrometer(2) (>0.8 mm(2)) was associated with a 60% chance of having a PNC. CONCLUSIONS: Despite balloon protection, PNCs occurred in 5.2% of patients who underwent CAS procedures. The maximum area of aspirated particles seems to be an indicator of increased risk for PNCs.

Aged↗

Ternary lanthanoid ruthenium gallides with a high gallium content: Ln(2)Ru(3)Ga(10) (Ln = Yb, Lu) with a new structure type and LnRu(2)Ga(8) (Ln = La-Nd) with CaCo(2)Al(8)-type structure.

The title compounds were prepared by reaction of the elemental components at high temperatures. The compounds Yb(2)Ru(3)Ga(10) and Lu(2)Ru(3)Ga(10) crystallize with a new structure type, which has been determined from the single-crystal X-ray data of Yb(2)Ru(3)Ga(10): P4/mbm, Z = 2, a = 881.9(1) pm, c = 632.5(1) pm. In this structure the gallium atoms form two-dimensionally infinite double layers that extend perpendicular to the tetragonal axis. They contain two-thirds of the ruthenium atoms. The other ruthenium and the ytterbium atoms are situated between the gallium double layers. The structure is closely related to that of Mn(2)Hg(5). The latter compound may be written with the formula Mn(2)Mn(2)(square)Hg(10), thus indicating that its structure may be regarded as a defect-variant of the presently reported structure of Yb(2)Ru(3)Ga(10). The four gallides of the series LnRu(2)Ga(8) (Ln = La-Nd) crystallize with the orthorhombic CaCo(2)Al(8)-type structure (Pbam, Z = 4). This structure has been refined from single-crystal X-ray data of the cerium and neodymium compounds. Slight deviations from the ideal composition for one of the two ruthenium sites resulted in the formulas CeRu(1.913(4))Ga(8) and NdRu(1.858(4))Ga(8). Magnetic susceptibility measurements with a SQUID magnetometer indicate diamagnetism for LaRu(2)Ga(8), which is partially compensated by the expected Pauli paramagnetism. The cerium atoms in CeRu(2)Ga(8) show mixed or intermediate valent behavior, and PrRu(2)Ga(8) follows the Curie-Weiss law with no magnetic order down to 4 K.

Journal Article↗

Influence of treatment modality on angiographic outcome after coronary stenting in diabetic patients: a controlled study.

OBJECTIVES: This retrospective study was designed to determine the six-month angiographic outcome after stenting of native coronary arteries in insulin-treated (ITDM) and non-ITDM patients with diabetes mellitus (DM) and compare the results with those in non-DM patients. BACKGROUND: The influence of the treatment modality for DM on restenosis in patients undergoing coronary artery stenting has not been elucidated sufficiently. METHODS: A total of 1,439 (70%) of 2,061 patients underwent repeated angiography within six months of coronary stenting. The ITDM and non-ITDM (oral hypoglycemic drugs or diet) were documented in 48 (3.3%) and 177 patients (12.3%), respectively, leaving 1,214 non-DM patients. RESULTS: Baseline reference vessel diameter tended to be smaller in ITDM patients (mean, 2.73 mm) than in non-DM and non-ITDM patients (2.88 mm and 2.85 mm, respectively). However, percent diameter stenosis was not different. The median number of stents deployed was 1; median stent length was 15 mm. Statistically significant differences were present after stenting for the means of minimal lumen diameter (MLD) and acute gain between ITDM patients (MLD: 2.67 mm, acute gain: 1.98 mm) and non-DM patients (MLD: 2.81 mm, acute gain: 2.16 mm). At follow-up, percent diameter stenosis, late lumen loss and loss index were significantly higher in both non-ITDM lesions (42%, 1.14 mm and 0.56, respectively) and ITDM lesions (48%, 1.26 mm and 0.65, respectively) than in non-DM lesions (35%, 0.96 mm and 0.45, respectively). The corresponding differences between non-ITDM and ITDM lesions did not reach statistical significance. Restenosis rates in non-DM, non-ITDM and ITDM lesions were 23.8%, 32.8% (p = 0.013 vs. non-DM) and 39.6% (p = 0.02 vs. non-DM, p = 0.477 vs. non-ITDM), respectively. CONCLUSIONS: This study showed that compared with stenting in non-DM patients, stenting of native coronary arteries in DM patients is associated with significantly increased lumen renarrowing, regardless of the treatment modality for DM.

Aged↗

Modification of the substrate for maintenance of idiopathic human atrial fibrillation: efficacy of radiofrequency ablation using nonfluoroscopic catheter guidance.

BACKGROUND: Catheter ablative techniques to modify the substrate to maintain atrial fibrillation (AF) require the creation of continuous radiofrequency current-induced ablation lines. This study was designed to assess the efficacy and safety of nonfluoroscopic mapping in this setting. METHODS AND RESULTS: A total of 45 consecutive patients with idiopathic AF were studied. The first 13 underwent ablation confined to the left atrium by creating a circular line isolating the pulmonary vein ostia and a second line connecting the former with the mitral annulus. Subsequently, 12 of these patients underwent a procedure confined to the right atrium (RA), where attempts were made to create an isthmus line between the inferior vena cava and the tricuspid annulus, an anterior line connecting the tricuspid annulus with the superior vena cava, and an intercaval line between the ostia of the inferior and superior venae cavae. In the last 32 patients, only the RA approach was performed. Technical difficulties prevented the creation of the intended left atrial line pattern: all patients experienced recurrences. A 100% recurrence rate was also observed after subsequent RA ablation, despite creation of a complete line pattern in 4 of 12 patients. Of the final 32 patients, AF recurred in 94%; a complete ablation line pattern had been achieved in 18 patients (56%), 16 of whom had recurrences. CONCLUSIONS: The electroanatomically-guided creation of extended radiofrequency current lesions is technically feasible only in the RA. However, procedural success in the RA does not suppress recurrences of AF in the majority of patients.

Atrial Fibrillation↗

Restenosis after stenting of matched occluded and non-occluded coronary arteries. Should there be a difference?

AIMS: It is not known whether the higher restenosis rates reported after balloon angioplasty of occluded as opposed to non-occluded coronary arteries are still found after placement of coronary stents in lesions matched for factors known to affect late angiographic outcome. METHODS AND RESULTS: In a retrospective analysis of 1276 patients who had undergone coronary stent placement and in whom 6-month angiographic follow-up was available, we identified 144 patients with a total coronary occlusion which matched a non-occluded coronary lesion in another 144 patients. Matching lesion pairs were of the same type (de novo or restenotic), were supplied with the same type of stent, had reference vessel diameters identical within 0.3 mm and stented vessel segment lengths identical within 8 mm, and were located in corresponding target vessels. After stenting, statistically identical minimal lumen diameters had been achieved in both groups (occluded: 2.74+/-0.35 mm, non-occluded: 2. 77+/-0.32 mm, P = 0.45). At follow-up, minimal lumen diameters were not different (occluded: 1.65+/-0.77 mm, non-occluded: 1.76+/-0.76 mm, P = 0.24), reflecting an identical late lumen loss for occlusions (1.09+/-0.76 mm) and non-occluded lesions (1.01+/-0.70 mm, P = 0.38). Because of the significantly larger acute gain, the loss index was significantly lower for occluded vessels (0.40+/-0.27 vs 0. 51+/-0.35, P = 0.003). Corresponding restenosis rates were 33% (occluded) and 28% (non-occluded;P = 0.44). For stented vessel segment lengths >18 mm, restenosis rates were markedly higher (occluded: 42%, non-occluded: 36%) than for stented vessel segment lengths </=18 mm (occluded: 25%, non-occluded: 22%). CONCLUSIONS: In occluded and non-occluded coronary lesions matched for factors known to affect the angiographic outcome, no difference between the respective restenosis rates was observed within 6 months of coronary stenting. Thus, either type of coronary lesion appears to exhibit the same propensity for neointimal hyperplasia.

Angioplasty, Balloon, Coronary↗

Information theoretical performance measure for associative memories and its application to neural networks.

We present a general performance measure (information loss) for associative memories based on information theoretical concepts. This performance measure can be estimated, provided that mean values of observables have been determined for the associative memory. Then the estimation guarantees a minimal association quality. The formalism allows the application of the performance measure to complex systems where the relation between input and output of the associative memory is not explicitly known. Here we apply our formalism to the Hopfield model and estimate the storage capacity alpha(c) from the numerically determined information loss. In contrast to other numerical methods the whole overlap distribution is taken into account. Our numerical value alpha(c)=0.1379(4) for the storage capacity in the Hopfield model is below numerical values obtained previously. This indicates that the consideration of small remnant overlaps lowers the storage capacity of the Hopfield model.

Artificial Intelligence↗

Ventricular tachycardia during follow-up in patients resuscitated from ventricular fibrillation: experience from stored electrograms of implantable cardioverter-defibrillators.

OBJECTIVE: The purpose of this study was to use the electrogram storage capabilities of the implantable cardioverter-defibrillator (ICD) to categorize any arrhythmic event during follow-up in a group of patients who had survived an episode of ventricular fibrillation (VF) and to possibly identify clinical predictors of future arrhythmic events. BACKGROUND: Little is known about the electrophysiologic characteristics of ventricular arrhythmias recurring during follow-up in survivors of VF as the sole documented arrhythmia at the time of resuscitation. METHODS: Forty patients (58+/-10 years; 73% men; left ventricular ejection fraction 42+/-18%; 70% with coronary artery disease) who had survived an episode of VF and subsequently received an ICD capable of intracardiac electrogram recording and storage were followed for 23+/-11 months. In all patients, the arrhythmogenic substrate was investigated by means of programmed electrical stimulation (PES). RESULTS: Among the 40 patients, 41 episodes of ventricular arrhythmias were documented in 13 patients (33%): 36 episodes of ventricular tachycardias (VT) were recorded in 11 patients (28%) and 5 episodes of VF were recorded in the remaining 2 patients (5%). Age, gender, cardiac disease and left ventricular ejection fraction failed to distinguish between patients with clinical recurrences and patients without. The sensitivity, specificity and positive accuracy of PES were 29%, 63% and 46%, respectively, for prediction of ventricular arrhythmia recurrence; 45%, 70% and 36%, respectively, for prediction of VT; and 50%, 98% and 50%, respectively, for prediction of VF during follow-up. CONCLUSIONS: In survivors of VF receiving ICD therapy, VT is the most common ventricular arrhythmia recorded on device-incorporated electrograms during follow-up. This finding, associated with the relatively well-preserved ventricular function, may account for the ability of these patients to survive at time of the index arrhythmia; the use of antitachycardia pacing as a modality to treat arrhythmia recurrences may contribute to reduce the incidence of shock during follow-up in these patients.

Aged↗

Stenting of nonacute total coronary occlusions: predictors of late angiographic outcome.

OBJECTIVES: This study was designed to determine and assess factors predictive of the intermediate-term outcome of stenting of nonacute total coronary occlusions. BACKGROUND: Balloon angioplasty of recanalized coronary occlusions is associated with a combined restenosis/reocclusion rate of up to 65%. Adjunctive stenting holds the potential to reduce this rate significantly. However, variables affecting the late angiographic outcome of coronary stenting in the setting of a total occlusion have not been elucidated sufficiently. METHODS: Coronary stenting was performed in 143 consecutive patients with a nonacute total occlusion; 120 of these patients (84%), with a total of 121 occlusions, underwent repeat angiography within 6 months and comprised the study group. High pressure stent implantation aimed to cover the site of the occlusion as well as adjacent diameter stenoses > or = 70% and all possibly induced dissections. Pertinent angiographic and procedural variables obtained at the time of the intervention were entered into a multivariate logistic regression analysis model to assess their influence on the angiographic outcome at follow-up. RESULTS: Mean preinterventional reference lumen diameter for the 121 vessels was 2.99 +/- 0.53 mm (mean +/- SD); occlusion length ranged from 4 to 44 mm (median of 7.7). After balloon angioplasty, dissections were found in 80% of patients. Lesions were covered with stents a median of 16 mm in length (range 8 to 53). The minimal lumen diameter (MLD) achieved after stenting was 2.89 +/- 0.48 mm. After a median follow-up period of 4.5 months, mean MLD was assessed at 1.91 +/- 0.90 mm, corresponding to a loss index of 0.34 +/- 0.31. There were 27 vessels with a nonocclusive restenosis > or = 50% and 8 with a reocclusion, for a combined restenosis/reocclusion rate of 29%. Factors found to adversely influence angiographic outcome were a post-stenting MLD < or = 2.54 mm, a stented vessel segment length > 16 mm, a balloon/vessel diameter ratio for final stent expansion < or = 1.00 and the presence of a dissection after balloon angioplasty. CONCLUSIONS: Compared with previous reports on stand-alone balloon angioplasty, stenting of nonacute total coronary occlusions lowers the 6-month restenosis/reocclusion rate to approximately 30%. The late procedural outcome is independently and statistically significantly influenced by the MLD after stenting, the length of the stented vessel segment, the balloon/vessel diameter ratio for final stent expansion and the incidence of dissections after balloon angioplasty.

Analysis of Variance↗

Appropriate mammalian expression systems for biopharmaceuticals.

Process development for biopharmaceuticals is dictated by product quality, drug safety and economy of the manufacturing process. Not surprisingly, these factors also play a key role in the evaluation of mammalian cell expression systems to be used in the production of pharmacologically active glycoproteins. To date, the most prominent candidates for efficient expression of glycoproteins are mammalian cell lines such as mouse fibroblast cells (C 127-BPV), Chinese hamster ovary cells (CHO-DHFR, CHO-NEOSPLA, CHO-GS), mouse myeloma cells (NSO-GS) as well as transgenic animals carrying c-DNA or genomic DNA which codes for the protein of interest. The expression titer in the case of glycoproteins is mainly determined by the promoter construct, the site of integration into the chromosome, the copy number and the type of protein in question. Based on expression titer, CHO-NEOSPLA and NSO-GS expression systems are most effective in the production of monoclonal antibodies and, to a lesser extent, of recombinant DNA derived proteins. However, based on overall product yield, expression of recombinant DNA derived proteins in transgenic animals is by far the most promising system. Therefore, for proteins required in large quantities, transgenic expression systems offer an attractive choice. However, cost of goods for products for which the dosage or the overall annual quantities are low, is dominated by downstream processing, filling, lyophilization and packaging and not by the fermentation process. Such proteins are preferentially produced by classical mammalian cell culture systems. Concerns which have to be addressed with respect to drug safety in the transgenic animal approach are the size of the herd, genetic stability from animal to animal, variation in productivity and in impurity profiles during lactation periods, microbial, viral, mycoplasma and prion contaminants, the dependence on health status and the life span of the animal. In a number of cases glycosylation of the protein is relevant for the prevention of immunogenicity of the protein, the pharmacological activity, the pharmacokinetic profile, solubility and stability against proteolysis. The glycosylation pattern, depending on protein structure, is influenced by the enzymatic system of the host cell as well as by fermentation conditions. Therefore, selection of host cells and culture conditions must take into account the requirement for a specific and stable glycosylation pattern. For the assessment of glycovariants, a number of protein analytical methods such as peptide mapping, isoelectric focusing, oligosaccharide mapping, MALDI-TOF (matrix assisted laser desorption mass spectrometry-time of flight), capillary electrophoresis and specific potency assays are available. In our experiments, glycosylation of proteins expressed in CHO cells was demonstrated to be very stable. Only extreme process times, cultivation methods and ammonium ion concentrations had an influence on the glycosylation profile. Among the three products investigated--tissue plasminogen activator (t-PA), interferon omega and soluble intercellular adhesion molecule (s-ICAM)--t-PA expressed the most stable glycosylation pattern. Only at extreme ammonium concentrations an increase of mannose-5 structures was observed, whereas biantennary complex structures were reduced. On the other hand, interferon omega and s-ICAM showed greater susceptibility to increased ammonium concentrations and to adherent cultivation. Such conditions induced quantitative changes to the glycosylation pattern favoring the appearance of higher branched structures. Short cultivation times resulted in more heterogenous oligosaccharide structures. Since the glycosylation of the three proteins is different in the same host cell, the amino acid sequence of the protein apparently influences the glycosylation pattern and its sensitivity to culture conditions. In NSO-mouse myeloma cells, production of s-ICAM is two times as high as in CHO cells

Animals↗

Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions.

BACKGROUND: Intravascular ultrasound (IVUS) provides more precise information than angiography about vascular dimensions. This information is used by some centers to optimize intracoronary stent implantation. There are no direct comparisons of the effects on restenosis of optimal IVUS-guided versus angiography-directed high-pressure stenting. METHODS AND RESULTS: Lesions of patients who had a 6-month angiographic follow-up study were eligible for matching. From 445 consecutive lesions treated by Palmaz-Schatz (P-S) stenting guided by IVUS (IVUS group) in Milan, 173 lesions were individually matched with 173 of 476 consecutive lesions treated by P-S stenting directed by angiography (Angio group) in Hamburg. Lesions were selected by a computerized program according to baseline clinical, angiographic, and procedural variables. Immediate and 6-month angiographic results were retrospectively compared, distinguishing an "early phase" from a "late phase." This distinction was based on the more aggressive dilation strategy with larger balloons and more demanding IVUS criteria for optimal stent expansion used in Milan in the early phase. In both phases, a larger minimum lumen diameter (MLD) immediately after stenting and after 6 months was achieved in the IVUS group than in the Angio group. In the early phase, the dichotomous restenosis rate was lower in the IVUS group than in the Angio group (9.2% versus 22.3%; P=.04). In the late phase, there was no difference in restenosis between the groups (22.7% versus 23.7%; P=1.0). CONCLUSIONS: In matched lesions treated with high-pressure stenting, IVUS guidance achieved a larger MLD than angiographic guidance. However, in the IVUS group, the restenosis rate was lower only in the early phase, when balloons larger than currently used were selected to maximize the stent lumen area.

Adult↗

[Anatomic distribution, conduction properties and recurrences after ablation of multiple in comparison with single accessory conduction pathways].

In 1076 consecutive patients referred for radiofrequency current catheter ablation, the anatomical distribution and conduction properties of accessory pathways (APs) as well as the mode of recurrence after ablation were retrospectively analyzed and compared in patients with multiple and single APs. Except for 17 patients with Ebstein's anomaly, the prevalence of patients of multiple APs in this cohort was 5.4%. Patients with multiple APs. as opposed to patients with a single AP, had significantly more often APs located on the right free wall (23% versus 10%) and--since the prevalence of septal APs was identical in both groups--less frequently APs located on the left free wall (44% versus 56%). Also, concealed APs were significantly more often encountered in patients with multiple APs (45% versus 24%). Recurrence of conduction across an AP which had presumably been ablated was observed in both groups with statistically equal incidence of < 5%. In 11 patients with multiple APs, the additional AP was only found at the repeat session. These "new" APs were mostly concealed (9 out of 11) and necessitated an intervention predominantly late after the initial ablation session. Intermittent concealed conduction appears to be a likely explanation for this phenomenon. Patients with multiple APs exhibit a higher incidence of right free-wall and concealed APs, yet they stand the same, approximately 95%, chance of cure as do patients with a single AP. Nearly 25% percent of repeat sessions in patients initially thought to have a single AP are caused by the late manifestation of an additional AP.

Adolescent↗

Short-term results and intermediate-term follow-up of laser wire recanalization of chronic coronary artery occlusions: a single-center experience.

OBJECTIVES: This study sought to elucidate the short-term efficacy and intermediate-term outcome of excimer laser recanalization of chronic coronary artery occlusions in patients in whom attempts at mechanical revascularization had failed. BACKGROUND: Recanalization of chronic coronary occlusions with the use of a mechanical guide wire fails in 30% to 50% of cases, mostly because of inability to pass the wire through the lesion. The value of using excimer laser energy in this setting has not yet been determined. METHODS: The study group comprised 66 consecutive patients with 68 chronic coronary occlusions. Patients were eligible for inclusion in the study if a previous attempt at mechanical revascularization had failed and if their angiographic status was such that 1) the vessel segment distal to the occlusion could be visualized by way of collateral vessels, 2) the entry point of the occlusion was clearly outlined, and 3) not more than one anatomic bend was expected within the occlusion. Excimer laser energy was applied to the lesion through a 0.018-in. (0.046 cm) fiber-optic guide wire. Adjunctive balloon angioplasty and stenting were performed in all successfully treated patients but one. RESULTS: Thirty-four occlusions (50%) in 32 patients (48%) could be crossed with the laser wire. Location and age of the occlusion had no adverse influence on the outcome of laser wire recanalization, nor did the presence of bridging collateral vessels, a major side branch at the site of the lesion or a blunt stump of the occlusion. An inverse relation was found between the success rate and the length of the occlusion, such that a 19% reduction of the success rate accompanied each 10-mm increment of the mean occlusion length. Thus, the success rate was 68% for lesions < or = 10 mm but only 25% for lesions > 30 to < or = 40 mm. The presence of a bend in the lesion exceeding 60 degrees was strongly related to procedural failure. During a median angiographic follow-up period of 18 weeks, restenosis > 50% (n = 6) or reocclusion (n = 4) was found in 10 of the 32 successfully treated patients, for an intermediate-term success rate of 33% (22 of 66). Clinical follow-up revealed improved anginal status in 21 patients (66%) after a median of 24 weeks. Major complications (death, myocardial infarction, emergency operation) were not encountered. CONCLUSIONS: Successful recanalization of a chronic coronary occlusion by using currently available laser wires can be expected in 50% of selected patients in whom attempts at mechanical revascularization fail. Restenosis or reocclusion accounts for an overall 6-month success rate of 35%.

Angioplasty, Balloon, Coronary↗

Mapping of the coronary sinus and great cardiac vein using a 2-French electrode catheter and a right femoral approach.

INTRODUCTION: Local electrograms recorded from the coronary sinus and great cardiac vein provide important information for the diagnosis of various arrhythmias and identification of target sites for ablation of left-sided accessory pathways. One limitation of present techniques is the inability, in many cases, to probe the great cardiac vein at the anterior mitral annulus. We tested the feasibility of a new technique for catheterization of the coronary sinus and great cardiac vein by means of a small-diameter electrode catheter advanced via a right femoral approach through an angiography catheter. METHODS AND RESULTS: Of 22 patients (12 men and 10 women; ages 44.5 +/- 13.4 years) undergoing radiofrequency ablation of a supraventricular tachycardia, cannulation of the coronary sinus orifice using a 6-French 1L or 2L Amplatz catheter was achieved in 20 patients (91%) within 0.9 +/- 0.6 minutes; after cannulation, a 2-French octapolar electrode catheter with a soft radiopaque tip and a 3-mm interelectrode distance could be advanced in all 20 patients through the guiding catheter to the great cardiac vein in the anterior region of the AV sulcus within 0.8 +/- 0.7 minutes. Atrial and ventricular local potentials were recorded all along the mitral annulus during sinus rhythm, atrial and ventricular pacing, or supraventricular tachycardia. Variation of local potential amplitude never exceeded 20% of the mean and presented similar stability at all annular regions. The arrhythmogenic substrate was identified in all patients. Of 18 patients with 21 left-sided accessory pathways, an accessory pathway potential could be recorded at the ablation site by one or more adjacent epicardial electrode pairs in 10 pathways. No procedure-related complications were observed. CONCLUSIONS: The technique introduced in this study proved feasible in 91% of patients. Its main advantages are the simplicity and rapidity of coronary sinus cannulation and the ability to advance the electrode catheter to the anterior cardiac vein. In addition, closely spaced bipolar electrograms resulted in enhanced atrial, ventricular, and accessory pathway potential resolution.

Adult↗