PubMed Health⌕ Search

Biomedical subjects

M Schlegelmilch

Publications and source records attributed to M Schlegelmilch.

7 recordsLinked to original sources

Development of a simple and sensitive method for the characterization of odorous waste gas emissions by means of solid-phase microextraction (SPME) and GC-MS/olfactometry.

A solid-phase microextraction (SPME) method has been developed for the extraction of odorous compounds from waste gas. The enriched compounds were characterized by gas chromatography-mass spectrometry (GC-MS) and gas chromatography followed by simultaneous flame ionization detection and olfactometry (GC-FID/O). Five different SPME fiber coatings were tested, and the carboxen/polydimethylsiloxane (CAR/PDMS) fiber showed the highest ability to extract odorous compounds from the waste gas. Furthermore, parameters such as exposure time, desorption temperature, and desorption time have been optimized. The SPME method was successfully used to characterize an odorous waste gas from a fat refinery prior to and after waste gas treatment in order to describe the treatment efficiency of the used laboratory scale plant which consisted of a bioscrubber/biofilter combination and an activated carbon adsorber. The developed method is a valuable approach to provide detailed information of waste gas composition and complements existing methods for the determination of odors. However, caution should be exercised if CAR/PDMS fibers are used for the quantification of odorous compounds in multi-component matrices like waste gas emissions since the relative affinity of each analyte was shown to differ according to the total amount of analytes present in the sample.

Chemistry Techniques, Analytical↗

Analytical determination of the suitability of different processes for the treatment of odorous waste gas.

In order to determine the efficiency of different treatment systems for the reduction of odorous emissions, a gas chromatographic method followed by simultaneous mass spectrometry and olfactometry (GC-MS/O) was developed. Samples from a coffee bean roasting and a fat and oil processing plant were analyzed, respectively. The results were compared with the data obtained by olfactometric measurements. At a coffee bean roasting plant, cooling gases were analyzed prior to and after treatment in a full scale bioscrubber. The GC-MS/O analysis showed that the amounts of aldehydes and ketones decreased after treatment of cooling gases of coffee bean roasting in the bioscrubber, whereas the contents of the heterocyclic compounds, like pyridine and the pyrazines, and acetophenone and guaiacol remained almost unchanged. The amounts of dimethyl disulfide, 3-hydroxy-2-butanone, and the carboxylic acids increased after bioscrubber treatment. Furthermore, the performance of each stage of a combined experimental plant for the treatment of exhaust air of fat and oil processing was investigated. This treatment plant consisted of a bioscrubber, a biofilter, and an activated carbon adsorber. The important odor-active compounds of the exhaust air of fat and oil processing were the typical fat oxidation products (aldehydes, ketones) and with lower importance 2-pentylfuran, a few terpenes and aromates. Again, the key odor-active compounds, aldehydes and ketones, were degraded in the bioscrubber. Further degradation of aliphatic, unsaturated, methylated, and cyclic alkanes, as well as aromates, terpenes, and furans by the biofilter was observed. After the last treatment stage, the activated carbon filter, only small amounts of aliphatic, unsaturated, methylated, and cyclic alkanes and aromates remained in the waste gas. For both applications, the results of the developed GC-MS/O method correlated very well with olfactometric measurements.

Air Pollution↗

Odour management and treatment technologies: an overview.

There is a large variety of options available for the effective treatment of odorous emissions. The most important physical, chemical and biological treatment processes are shortly described and their favourable applications, as well as their limits, are highlighted. But for a sustainable solution of an industrial odour problem, there is more involved than just the installation of a waste gas treatment system. This article focuses on a general and systematic approach towards extensive odour management. First of all, an odour assessment should be worked out where all actual and potential odour emission sources are recorded and characterised. A special focus should be set on fugitive emissions, which may have an enormous impact on the overall odour problem. They need to be captured before they can be supplied to a treatment system. According to the composition and condition of the waste gases, an appropriate treatment system must be selected. For this purpose, test systems have been developed and are presented in this article.

Absorption↗

A macrokinetic model for dimensioning of biofilters for VOC and odour treatment.

Biofiltration is a cost-effective and environmentally sustainable technology for the treatment of exhaust gases from a variety of sources. Although the process setup is relative simple, many physical, chemical, and microbiological processes are involved. Microkinetic models attempting to cover all of these processes are often more complex than reliable; on the other hand, many macrokinetic approaches have a tendency to oversimplification. In order to develop a simple and accurate protocol to derive biofilter design criteria from experimental trials, a macrokinetic model based on chemical engineering fundamentals was developed. The model covers first-order kinetics as well as kinetics shifting from first-order at low substrate concentrations to zero-order at elevated concentrations and can be applied to single VOCs and odours as measured by olfactometry.

Bioreactors↗

Odour control at biowaste composting facilities.

There are several options to effectively reduce odorous emissions at composting facilities depending on the type of composting system used. Some of the more relevant measures for open and enclosed composting facilities are presented in this article. Results from different investigations on odour reduction efficiencies of biological waste gas treatment systems at various scales are presented. Biofilter/bioscrubber combinations were used and different biofilter materials were tested. The more relevant odorous substances in the waste gas were identified, and their reduction in the different systems was measured. The biofilter proved to be mainly responsible for efficient odour degradation. The investigations presented in this article revealed that screened compost was very effective, and proved to be a low cost biofilter material for odour degradation purposes. Screened compost showed higher degradation rates than a coke-compost mixture newly developed by the University of Leipzig. Furthermore, it seems that enclosed systems have advantages when compared to conventional open single bed biofilters.

Air Pollution↗

The potential to reduce emissions of airborne microorganisms by means of biological waste gas treatment systems.

Investigations regarding the reduction of airborne germs in the waste gas of biowaste composting processes have been carried out at the Hamburg University of Science and Technology and the University of Leipzig. Numerous waste gas treatment plants, ranging from laboratory-scale to technical-scale, have been available at the institutes of these two project partners. All plants consisted of bioscrubber/biofilter combinations. The results showed that these biological systems designed for odour control are able to successfully reduce bioaerosol emissions, even though a reduction to background levels could not be achieved. The bioscrubber, if equipped with a droplet separator, proved to be mainly responsible for the reduction, whereas the biofilter acted as a source for microbial emissions originating from the filter material. It could be observed that the microbial population changed while passing the treatment system, indicating the ability of biological waste gas treatment systems to retain potentially pathogenic microorganisms from waste gases.

Air Microbiology↗

Investigation and optimization of composting processes-test systems and practical examples.

To determine the optimal course of composting it is useful to carry out experiments. The selection of the right experimental set-up depends on the question of concern. Each set-up is useful for a particular application and has its limits. Two test systems of different scales (up to 1500 ml; up to 100 l) are introduced. The purpose and importance of each system design shall be highlighted by application examples: (1). Suitability of a liquid industrial residue as composting accelerator; (2). Determination of the compost maturity; (3). Behaviour of odor-reducing additives during waste collection and composting; (4). Production of tailor-made compost with respect to Nitrogen (5). Suitability of O(2)-enriched air for acceleration of composting. Small-scale respiration experiments are useful to optimize parameters which have to be adjusted during substrate pre-treatment and composting, with the exception of particle size and temperature, and to reduce the number of variants which have to be investigated in greater detail in larger scale experiments. As all regulation possibilities such as aeration, moistening, turning can be simulated with the technical scale set-up, their complex cooperation can be taken into consideration. Encouraging composting variants can be tested, compared and optimized.

Conservation of Natural Resources↗