PubMed Health⌕ Search

Biomedical subjects

M Schwaibold

Publications and source records attributed to M Schwaibold.

18 recordsLinked to original sources

Automated sleep stage detection with a classical and a neural learning algorithm--methodological aspects.

For classification tasks in biosignal processing, several strategies and algorithms can be used. Knowledge-based systems allow prior knowledge about the decision process to be integrated, both by the developer and by self-learning capabilities. For the classification stages in a sleep stage detection framework, three inference strategies were compared regarding their specific strengths: a classical signal processing approach, artificial neural networks and neuro-fuzzy systems. Methodological aspects were assessed to attain optimum performance and maximum transparency for the user. Due to their effective and robust learning behavior, artificial neural networks could be recommended for pattern recognition, while neuro-fuzzy systems performed best for the processing of contextual information.

Algorithms↗

[Development of Bluetooth wireless sensors].

Wireless communication could help to overcome current obstacles in medical devices and could enable medical services to offer completely new scenarios in health care. The Bluetooth technology which is the upcoming global market leader in wireless communication turned out to be perfectly suited not only for consumer market products but also in the medical environment [1]. It offers a low power, low cost connection in the medium range of 1-100 m with a bandwidth of currently 723.2 kbaud. This paper describes the development of a wireless ECG device and a Pulse Oximeter. Equipped with a Bluetooth port, the measurement devices are enabled to transmit data between the sensor and a Bluetooth-monitor. Therefore, CSR's Bluetooth protocol embedded two-processor and embedded single-processor architecture has been used.

Electrocardiography↗

Design aspects for novel, telemedical unattended diagnosis and therapy control systems for sleep disorders.

Medical research confirmed the relevance of diagnosis and therapy of sleep-related breathing disorders, revealing prevalence and patho-physiological mechanisms [1-10]. Reliable sleep assessment currently demands examinations in the sleep-lab, which is very technical and time-consuming. Thus, expanding the conventional procedure to meet capacity demands does not seem realistic regarding cost aspects. As a solution, the authors present telemetric system concepts for the unattended assessment of a patient's sleep profile and cardio-respiratory parameters. Taking initial experience with home polysomnography into consideration, the presented research work focuses on easily applicable sensors, the corresponding sleep profile assessment rules, wireless data recording, intelligent signal processing algorithms and telemedical information logistics to include sleep-labs in the diagnosis and treatment process as competence centers.

Algorithms↗

The wireless monitoring of vital parameters: a design study.

This project shows the way vital parameters can be transmitted and visualized with no connecting cables necessary to the PDA. This was realized using a sensor developed with an integrated Bluetooth interface and a PDA, also equipped with Bluetooth. This radio connection can span up to 10 m, and parameters, such as pulse frequency, oxygen saturation in blood, ECG measurements and plethysmograms, can be transmitted. Using the software introduced in this work, the transmitted measurements can be displayed numerically or graphically on the PDA. The software simultaneously checks for any limits and sends a warning message if these limits are exceeded. All received data are additionally documented.

Computer Graphics↗

Miniaturized module for the wireless transmission of measurements with Bluetooth.

The wiring of patients for obtaining medical measurements has many disadvantages. In order to limit these, a miniaturized module was developed which digitalizes analog signals and sends the signal wirelessly to the receiver using Bluetooth. Bluetooth is especially suitable for this application because distances of up to 10 m are possible with low power consumption and robust transmission with encryption. The module consists of a Bluetooth chip, which is initialized in such a way by a microcontroller that connections from other bluetooth receivers can be accepted. The signals are then transmitted to the distant end. The maximum bit rate of the 23 mm x 30 mm module is 73.5 kBit/s. At 4.7 kBit/s, the current consumption is 12 mA.

Amplifiers, Electronic↗

Evaluation and optimization of different spectral estimation methods for EEG signals.

The goal of this work was the evaluation of various spectral estimation methods with regard to their suitability for classifying EEG data. A test environment was implemented in which the algorithms are optimized and evaluated using various artificial and real EEG data. The methods are based on autoregressive approaches, as well as from FFT, wavelet, and matching pursuit-based spectral estimations. The evaluation showed that the quality of the results strongly correlate with the computational effort of the algorithm. The matching pursuit algorithm (MP) was implemented and further optimized since it had the best test result and had good scalability. Even under a sufficiently low runtime, it still gave good results.

Algorithms↗

[Artificial intelligence in sleep analysis (ARTISANA)--modelling visual processes in sleep classification].

We describe a novel approach to the problem of automated sleep stage recognition. The ARTISANA algorithm mimics the behaviour of a human expert visually scoring sleep stages (Rechtschaffen and Kales classification). It comprises a number of interacting components that imitate the stepwise approach of the human expert, and artificial intelligence components. On the basis of parameters extracted at 1-s intervals from the signal curves, artificial neural networks recognize the incidence of typical patterns, e.g. delta activity or K complexes. This is followed by a rule interpretation stage that identifies the sleep stage with the aid of a neuro-fuzzy system while taking account of the context. Validation studies based on the records of 8 patients with obstructive sleep apnoea have confirmed the potential of this approach. Further features of the system include the transparency of the decision-taking process, and the flexibility of the option for expanding the system to cover new patterns and criteria.

Adult↗

Delayed VO2 kinetics during ramp exercise: a criterion for cardiopulmonary exercise capacity in chronic heart failure.

PURPOSE: Kinetics of VO2 at onset of constant work rate exercise was previously shown to be slowed in patients with chronic heart failure (CHF) compared with that in healthy normals. Because bicycle ergometry with ramp protocol is usually used for exercise testing with CHF patients, it would be of practical importance if it can be shown that a delay in the time interval of linear increase of VO2 (TILIV) to work rate occurs after beginning ramp exercise. Data of central hemodynamics (CHF) and noninvasive cardiopulmonary parameters (CHF, normals) should also correlate with VO2 delay time if this parameter is related to cardiopulmonary exercise capacity. METHODS: Fifteen males with CHF (mean +/- SEM: age 52 +/- 2 yr; ejection fraction 32 +/- 4%; peak cardiac index 3.9 +/- 0.3 L x m(-2) x min(-1)) and 28 healthy males (50 +/- 1 yr) were assessed. During ramp bicycle ergometry (3 min unloaded, work rate increments of 12.5 W x min(-1)), VO2 was measured breath by breath. RESULTS: After the onset of ramp exercise, there was a difference in the TILIV between patients and normals (83.7 +/- 3.6 vs 66.8 +/- 2.9 s; P < 0.001). Significant differences between both groups were also found for VO2 at ventilatory threshold (VT) (10.1 +/- 0.1 vs 15.2 +/- 0.7 mL x kg(-1) x min(-1); P < 0.0001), VO2 at VT relative to predicted VT (58 +/- 4 vs 97 +/- 4%; P < 0.0001), peak VO2 (13.2 +/- 1.0 vs 34 +/- 1.4 mL x kg(-1) x min(-1), P < 0.001), and increase of systolic blood pressure (36 +/- 7 vs 71 +/- 5 mm Hg; P < 0.0001). In CHF, the TILIV correlated significantly with peak cardiac index and VO2 at VT (r = -0.71; P < 0.005 each), relative value of VO2/kg at VT (r = -0.61; P < 0.03), peak VO2/kg (r = -0.63; P < 0.01), and increase of systolic blood pressure (r = -0.52; P < 0.02). In the normals only VO2/kg at VT correlated significantly with TILIV (r = -0.41; P < 0.03). In patients, stepwise regression analysis identified three predictors which could explain 79% of the variance of TILIV: VO2/kg at VT (r2 = 0.51), peak cardiac index (r2 = 0.20), and peak VO2/kg (r2 = 0.08). CONCLUSION: TILIV, determined at the onset of ramp exercise, is prolonged in CHF patients compared with that in normals and reflects severity of functional impairment because of reduced cardiac index and aerobic capacity. TILIV can provide information about changes in cardiopulmonary exercise capacity and thus can be used for follow-up and treatment studies in CHF.

Cardiac Output, Low↗

Predictors of response to exercise training in severe chronic congestive heart failure.

We prospectively assessed whether baseline central hemodynamics and exercise capacity can predict improvement of VO2 at ventilatory threshold (VT) after exercise training in patients with severe chronic congestive heart failure. Eighteen patients (mean +/- SEM; age 52 +/- 2 years), half of them listed for transplant, underwent 3 weeks of exercise training (interval cycle and treadmill walking; 5 x/week) and 3 weeks of activity restriction in a random-order crossover trial. Baseline data were not significantly different for groups with exercise training first and activity restriction first: cardiac index at rest (2.1 +/- 0.1 L/m2/min), maximum cardiac index (3.1 +/- 0.2 L/m2/min) (Fick), and echocardiographic ejection fraction (21 +/- 1%). The same was true for cardiopulmonary exercise data (cycle ergometry; up 12.5 W/min): VO2 at VT (9.3 +/- 0.4 ml/kg/min), maximum VO2 (12.2 +/- 0.7 ml/kg/min), VT in percentage of predicted maximum VO2 (31 +/- 2%), heart rate at VT (95 +/- 4 beats/min), and decrease of dead space-to-tidal volume ratio from rest to VT (33 +/- 1 --> 29 +/- 1). Improvement of VO2 at VT after training (2.2 +/- 0.4 ml/kg/min; p <0.001) was not related to baseline central hemodynamics (r = <0.10 for each), but was greater in patients with a lower baseline VO2 at VT (r = -0.65; p <0.01), peak VO2 (r = -0.66; p <0.01), VT in percentage of predicted maximum VO2 (r = -0.74; p <0.001), heart rate at VT (r = -0.63; p <0.01), and smaller decrease of dead space-to-tidal volume ratio from rest to VT (r = 0.65; p <0.01). Ejection fraction after exercise training (24 +/- 2%) and activity restriction (23 +/- 2%) did not differ significantly compared with baseline, and patient status (heart failure and cardiac rhythm) remained stable. Three parameters accounted for 84% of the variance of improvement in VO2 at VT: VO2 at VT in percent predicted maximum VO2, decrease of dead space-to-tidal volume ratio, and heart rate at VT. The findings suggest that there was a greater increase in VO2 at VT after exercise training in patients with greater peripheral deconditioning at baseline. The improvement was unrelated to central hemodynamics. Clinically stable patients with severe chronic congestive heart failure, potential heart transplant candidates, and those awaiting transplantation may benefit from involvement in a short-term exercise training program.

Exercise↗

Short-term reproducibility of cardiopulmonary measurements during exercise testing in patients with severe chronic heart failure.

Eleven men with severe chronic heart failure (peak cardiac index 4.0 +/- 0.2 L/m2/min), six on a heart transplantation waiting list, were prospectively assessed. To determine reproducibility of cardiopulmonary and hemodynamic variables for clinical purposes during ramp bicycle ergometry, the patients underwent two ramp bicycle ergometer tests (3 minutes unloaded, work rate increments of 12.5 W/min) with a 1-week interval between tests. Oxygen uptake (VO2) carbon dioxide production (VCO2), and ventilation were measured breath by breath, and calculations were performed to determine gas exchange ratio, oxygen pulse, ventilatory equivalents of oxygen and carbon dioxide, and end-tidal partial pressure for oxygen and carbon dioxide. Additionally, heart rate, blood pressure, and lactate levels were assessed. Measurements were performed at submaximum work rate levels of 25 W, 50 W, and 75 W at ventilatory threshold and at peak work rate. At all measurement points, the coefficient of variation for cardiopulmonary variables was between 1.4% and 7.1% for submaximum work rate levels, between 1.2% and 4.4% at ventilatory threshold, and between 2.4% and 7.1% at peak work rate. For heart rate, blood pressure, and lactate levels, coefficient of variation was between 2.7% and 5.7% for submaximum work rate levels, between 1.4% and 6.1% at ventilatory threshold, and between 1.2% and 5.5% at peak work rate. The data suggest high reproducibility for duplicate measurements of cardiopulmonary and hemodynamic variables during ramp bicycle ergometry in patients with severe chronic heart failure. The results may be used to determine whether any variable in a single patient is significantly different from that obtained in a previous exercise test or if the change is within experimental error.

Anaerobic Threshold↗

Effects of exercise training and activity restriction on 6-minute walking test performance in patients with chronic heart failure.

Eighteen hospitalized patients with severe chronic heart failure (ejection fraction [mean +/- SEM] 21% +/- 1%) underwent 3 weeks of exercise training (interval bicycle ergometer and treadmill walking training exercises) and 3 weeks of activity restriction in a random-order crossover trial. Before and after exercise training and after activity restriction, a 6-minute walking test was performed to determine the maximum distance walked, hemodynamic and cardiopulmonary responses, norepinephrine levels, and ratings of leg fatigue and dyspnea while walking. A ramp test on bicycle ergometer (increments of 12.5 W/min) was performed before and after exercise training and activity restriction to determine peak oxygen uptake. After training, the maximum distance walked was increased by 65% (from 232 +/- 21 m at baseline to 382 +/- 20 m; p < 0.001), whereas after activity restriction (253 +/- 19 m) there was no significant difference compared with baseline. No significant differences in hemodynamic and cardiopulmonary parameters (with the exception of the ventilatory equivalent for carbon dioxide and perceived exertion) or norepinephrine levels were observed during walking tests. Improvement in maximum distance walked correlated significantly with training-induced increase in peak oxygen uptake measured during bicycle ergometry (r = 0.47, p < 0.05). The lower the maximum distance walked at baseline, the more pronounced the training-induced prolongation of maximum distance (r= -0.73; p < 0.001). These data support the value of exercise training in patients with severe chronic heart failure for improving maximum distance walked, as documented by the 6-minute walking test. The impairment of walking test performance during activity restriction suggests a need for long-term exercise training programs.

Activities of Daily Living↗

Interval training in patients with severe chronic heart failure: analysis and recommendations for exercise procedures.

This study analyzes a new exercise training procedure, which includes interval exercise training on cycle ergometer (IntCT) (30-s work phases/60-s recovery phases) and on treadmill (60-s work and recovery phases each). Training was applied for 3 wk in 18 patients with severe chronic heart failure (CHF) ((mean +/- SEM) age 52 +/- 2 yr, ejection fraction 21 +/- 1%). Peak VO2 was increased from 12.2 +/- 0.7 to 14.6 +/- 0.7 ml-kg-1 min-1 owing to training (P < 0.001). A specific steep ramp test (work rate increments 25 W.10 s-1) was developed to derive exercise intensity for work phases in IntCT, which was 50% of the maximum work rate achieved. Steep ramp test was performed at the start of the study to determine the initial training work rate, then weekly to readjust it. Since the maximum work rate achieved from this test increased weekly (144 +/- 10 W -->172 +/- 10 W-->200 +/- 11 W; P < 0.001), the training work rate also increased (72 +/- 4 W-->86 +/- 6 W-->100 +/- 7 W; P < 0.001). Physical responses to IntCT were measured. There was no significant change in heart rate, blood pressure, and ratings of perceived exertion (RPE) using a Borg Scale between the first and the third week of training (heart rate 88 +/- 3 b.min-1; blood pressure 115 +/- 4/80 +/- 2 mm Hg; leg fatigue 12 +/- 1; dyspnea 10 +/- 1). Mean lactate concentration (1.70 +/- 0.09 mmol-1-1) indicated an overall aerobic range of training intensity. When compared with the commonly used intensity level of 75% peak VO2 from an ordinary ramp test (work rate increments 12.5 W.min-1), the performed training work rate was more than doubled (240%; P < 0.0001) while cardiac stress was lower (86%; P < 0.01). Values of norepinephrine and epinephrine as well as of RPE corresponded to those measured at 75% peak VO2. Interval exercise training is thus recommended for selected patients with CHF as it allows intense exercise stimuli on peripheral muscles with minimal cardiac strain. Using a steep ramp test, training work rate can be determined and readjusted weekly during initial training period.

Bicycling↗

Effects of short-term exercise training and activity restriction on functional capacity in patients with severe chronic congestive heart failure.

Previous exercise training studies in patients with chronic congestive heart failure (CHF) were performed for periods lasting > 2 months, and effects of activity restriction on exercise induced-benefits were not systematically assessed. With one exception study, patients were not reported to be transplant candidates. In this random-order crossover study, effects of 3 weeks of exercise training and 3 weeks of activity restriction on functional capacity in 18 hospitalized patients with severe CHF [(mean +/- SEM) age 52 +/- 2 years; ejection fraction 21 +/- 1%; half of them on a transplant waiting list] were assessed. The training program consisted of interval exercise with bicycle ergometer (15 minutes) 5 times weekly, interval treadmill walking (10 minutes), and exercises (20 minutes), each 3 times weekly. With training, the onset of ventilatory threshold was delayed (p < 0.001), with increased work rate by 57% (p < 0.001) and oxygen uptake by 23.7% (p < 0.001). On average, there was a 14.6% decrease in slope of ventilation/carbon dioxide production before the onset of ventilatory threshold (p < 0.05), and ventilatory equivalent of carbon dioxide production by 10.3% (p < 0.01). At the highest comparable work rate (56 +/- 5 W) the following variables were decreased: heart rate (7.3%; p < 0.05), lactate (26.6%; p < 0.001), and ratings of perceived leg fatigue and dyspnea (14.5% and 16.5%; p < 0.001 each). At peak exercise, oxygen uptake was increased by 19.7% (p < 0.01) and oxygen pulse by 14.2% (p < 0.01). There was a correlation of baseline peak oxygen uptake and increase of peak oxygen uptake due to training (r = -0.75; p < 0.004). Independently of the random order, data after activity restriction did not differ significantly from data measured at baseline. Patients with stable, severe CHF can achieve significant improvements in aerobic and ventilatory capacity and symptomology by short-term exercise training using interval exercise methods. Impairments due to activity restriction suggest the need for long-term exercise training.

Chronic Disease↗

Cardiopulmonary determinants of functional capacity in patients with chronic heart failure compared with normals.

BACKGROUND: Patients with chronic heart failure (CHF) are characterized by abnormal gas exchange and ventilatory responses to exercise. HYPOTHESIS: This study compares variables obtained from cardiopulmonary exercise testing in 35 patients with CHF with 35 age- and weight-matched healthy subjects. A second goal was to obtain cardiopulmonary variables measured at ventilatory threshold to distinguish patient changes from those of healthy subjects. METHODS: Exercise testing was carried out using bicycle ergometry with ramplike protocol (work rate increments 12.5 W/min). Gas exchange and ventilation were measured breath by breath. RESULTS: Compared with healthy subjects, the VO2 in patients was lower at identical work rates (p < 0.004) and at ventilatory threshold (p < 0.0001), and the slope of the VO2 curve during incremental exercise was flatter (p < 0.05). With the exception of heart rate, the variables for VO2, VCO2, ventilation, O2 pulse, ventilatory equivalents for O2 and CO2, and VD/VT (physiologic deadspace to tidal volume ratio), as well as lactate differed significantly at identical work rates. With the exception of VD/VT, all cardiopulmonary variables showed significant differences in their slopes during exercise. By means of a discriminant analysis, VCO2 and ventilation proved to be the most distinguishing variables at ventilatory threshold between patients with CHF and healthy subjects. CONCLUSIONS: These results indicate the clinical usefulness of cardiopulmonary exercise testing when assessing functional impairment due to CHF. For treatment evaluation, not only VO2 but also VCO2 and ventilation responses to exercise should be considered.

Adult↗

Ventilatory and lactate threshold determinations in healthy normals and cardiac patients: methodological problems.

In healthy normal individuals (n = 69), coronary patients with myocardial ischaemia (n = 27) and patients with chronic heart failure (CHF, n = 33), four widely applied methods to determine ventilatory threshold (VT) were analysed: V-slope, ventilatory equivalent for O2 (EqO2), gas exchange ratio (R) and end-tidal partial pressure of oxygen. Lactate threshold [LAT, log lactate vs log oxygen uptake (VO2)] was also determined. Analysis focused on rate of success of threshold determination, comparability of threshold methods, reproducibility and interobserver variability. Cycle ergometry protocols with ramp-like mode and graded steady-state mode used in exercise testing were considered separately. In healthy normal individuals and coronary patients with myocardial ischaemia, at least three VT could be determined during ramp-like mode and two VT during graded steady-state mode, 82% of the time. For CHF patients, the rate of successful determination of VT was lower. Compared to LAT, VO2 at VT was significantly higher using R and EqO2 methods of VT determination in healthy normal subjects (P < 0.01), and significantly higher when using all four methods in coronary patients (P < 0.01 or P < 0.05, respectively). No difference was observed between VO2 at VT and LAT in CHF patients. In healthy normal individuals, day-to-day reproducibility of VT and LAT was high (error of a single determination from duplicate determinations was between 3.9% and 6.2% corresponding to a VO2 of 52.2 and 89.2 ml.min-1). Interobserver variability was low (error between 0.3% and 5% corresponding to a VO2 of 9.8 and 68 ml.min-1). In CHF patients, interobserver variability was moderately greater (error between 4.6% and 8.2%, corresponding to a VO2 of 35.1 and 62.4 ml.min-1). To optimize threshold determination, standardized procedures are suggested.

Adolescent↗

Physical responses to different modes of interval exercise in patients with chronic heart failure--application to exercise training.

METHOD: In exercise training with chronic heart failure patients, working muscles should be stressed with high intensity stimuli without causing cardiac overstraining. This is possible using interval method exercise. In this study, three interval exercise modes with different ratios of work/ recovery phases (30/60 s, 15/60 s and 10/60 s) and different work rates were compared during cycle ergometer exercise in heart failure patients. Work rate for the three interval modes was 50% (30/60 s), 70% (15/60 s) and 80% (10/60 s) of the maximum achieved during a steep ramp test (increments of 25 w/10 s) corresponding to 71, 98 and 111 watts on average. Metabolic and cardiac responses to the three interval exercises were then examined including catecholamine levels and perceived exertion. Parameters measured during interval exercise were compared with an intensity level of 75% peak VO2, determined during an ordinary ramp exercise test (increments of 12.5 W.min-1). RESULTS: (mean +/- SEM) (1) In all three interval modes, VO2, ventilation and lactate did not increase significantly during the course of exercise. Mean values during the last work phase were between 754 +/- 30 and 803 +/- 46 ml.min-1 for VO2, between 26 +/- 3 and 28 +/- 1 l.min-1 for ventilation and between 1.24 +/- 0.14 and 1.29 +/- 0.10 mmol.l-1 for lactate. (2) In mode 10/60 s, heart rate and systolic blood pressure increased significantly (82 +/- 4 --> 85 +/- 4 beats.min-1; 124 +/- 5 --> 134 +/- 5 mmHg; P < 0.05 each), while in mode 15/60 s catecholamines increased significantly (norepinephrine 0.804 +/- 0.089 --> 1.135 +/- 0.094 nmol.l-1; P < 0.008; epinephrine 0.136 +/- 0.012 --> 0.193 +/- 0.019 nmol.l-1; P < 0.005). (3) In all three modes, rating of leg fatigue and dyspnoea increased significantly during exercise but remained within the range of values considered 'very light to fairly light' on the Borg scale. (4) Compared to an intensity level of 75% peak VO2, work rate during interval work phases was between 143 and 221%, while cardiac stress (rate-pressure product) was significantly lower (83-88%). CONCLUSION: All three interval modes resulted in physical response in an acceptable range of values, and thus can be recommended.

Chronic Disease↗

Influence of different exercise protocols on functional capacity and symptoms in patients with chronic heart failure.

This study compares hemodynamic, metabolic, and gas exchange responses, catecholamine levels, and symptoms in 35 male patients with chronic heart failure (CHF) ([mean +/- SD] age 53 +/- 11 yr; ejection fraction 24 +/- 11%) during three differently graded exercise test protocols. On three consecutive days patients performed cycle ergometry supine, with prolonged steps (prol BE) and right heart catheterization, ramplike cycle ergometry sitting (ramp BE), and ramplike treadmill walking (TMW). As in routine clinical practice, the prol BE was terminated when pathologic central hemodynamics and/or increased symptomology occurred, and ramp BE and TMW due to increased symptomology and/or physician's decision. During prol BE at ventilatory threshold (VT) the VO2 (8.6 +/- 1.8 ml.kg-1.min-1) was lower than during ramp BE (9.3 +/- 2.1 ml.kg-1.min-1) (P < 0.017) and TMW (11.8 +/- 2.3 ml.kg-1.min-1) (P < 0.0001). Prol BE, ramp BE, and TMW also differed significantly with respect to ventilation (22 +/- 7 l.min-1; 26 +/- 6 l/min-1; 29 +/- 7 l.min-1; P < 0.01) and heart rate (100 +/- 15 beats.min-1; 103 +/- 18 beats.min-1; 110 +/- 16 beats.min-1; P < 0.017). No differences were found in lactate levels, catecholamine levels, and ratings of leg fatigue and dyspnea. At test termination, the peak VO2 during prol BE (100.8 +/- 3.3 ml.kg-1.min-1) was lower than during ramp BE (13.3 +/- 4.1 ml.kg-1.min-1) (P < 0.0001) and TMW (14.7 +/- 3.4 ml.kg-1.min-1) (P < 0.0001). Peak norepinephrine value during ramp BE (4.531 +/- 2.788 nmol.l-1) was higher than during prol BE (3.707 +/- 2.262 nmol.l-1) (P < 0.001). Among the three tests, no significant differences were found for peak values of heart rate, lactate, and ratings of dyspnea. Although the VO2.kg-1 at VT was significantly higher during ramp BE and TMW compared to prol BE (P < 0.001), the values expressed as a percent of peak VO2.kg-1 were significantly lower (70 +/- 4%; 72 +/- 6%; 79 +/- 3%; P < 0.017). A systematic effect on aerobic capacity with reduced peak values during ramp BE and TMW was demonstrated when test termination was based primarily on pathological findings of central hemodynamics from prol BE.

Adolescent↗

Aerobic capacity and functional classification of patients with severe left-ventricular dysfunction.

Classes I/II and III of the classification systems of the New York Heart Association (NYHA), Canadian Cardiovascular Society (CCS) and American Medical Association (AMA) were compared with each other and with the Weber classification (O2 uptake, VO2/kg during treadmill walking) in 35 male patients with severe left ventricular dysfunction. Measured end points were ventilatory threshold (VT) and peak exercise. Also investigated was whether the CCS and AMA scales, due to their more stringent differentiation, are more precise than the NYHA system in determining a limited physical capacity and whether there are other differentiating factors useful in classification which may be derived from cardiopulmonary exercise testing. At the VT, the mean VO2/kg did not differ significantly in any classification system between classes I/II and III (12.8 +/- 2.5 vs. 11.1 +/- 2.3 ml/kg/min) and corresponded to Weber class B. At peak exercise, the mean VO2/kg only differed significantly within the NYHA classification; classes I/II (16.3 +/- 3.1 ml/kg/min) corresponded to Weber class B, and class III (13 +/- 3 ml/kg/min) to Weber class C. The individual values displayed a large scatter. Factors differing in classes I/II and III of all three systems at peak exercise were the ventilatory equivalent of O2 and CO2 as well as end-tidal partial pressure for O2 and CO2. At VT these factors showed a separating character only in the AMA classification. It is not possible to determine objective functional impairment by use of the NYHA, CCS and AMA systems because they are not analogous to the Weber system. Nevertheless, these classification systems can be used for clinical assessment and follow-up.

Exercise Test↗