PubMed HealthSearch

Biomedical subjects

M Shiffrar

Publications and source records attributed to M Shiffrar.

3 recordsLinked to original sources

Motion integration across differing image features.

To interpret the projected image of a moving object, the visual system must integrate motion signals across different image regions. Traditionally, researchers have examined this process by focusing on the integration of equally ambiguous motion signals. However, when the motions of complex, multi-featured images are measured through spatially limited receptive fields, the resulting motion measurements have varying degrees of ambiguity. In a series of experiments, we examine how human observers interpret images containing motion signals of differing degrees of ambiguity. Subjects judged the perceived coherence of images consisting of an ambiguously translating grating and an unambiguously translating random dot pattern. Perceived coherence of the dotted grating depended upon the degree of concurrence between the velocities of the grating terminators and dots. Depth relationships also played a critical role in the motion integration process. When terminators were suppressed with occlusion cues, coherence increased. When dots and gratings were presented at different depth planes, coherence decreased. We use these results to outline the conditions under which the visual system uses unambiguous motion signals to interpret object motion.

Depth Perception

The influence of terminators on motion integration across space.

Individual motion measurements are inherently ambiguous since the component of motion parallel to a homogeneous translating edge cannot be measured. Numerous models have proposed that the visual system solves this ambiguity through the integration of motion measurements across disparate contours. To examine this proposal, subjects observed a translating diamond through four stationary apertures. Since the diamond's motion could not be determined from any single contour, motion integration across contours was required to determine the diamond's direction of motion. We demonstrate that observers have difficulty accurately integrating motion information across space. Performance improved when the diamond stimulus was presented at 7 degrees eccentricity, through jagged apertures, or at low contrast. Taken together, these results imply that integration across space is more likely when the motion of contour terminators is less salient or reliable.

Contrast Sensitivity

Percepts of rigid motion within and across apertures.

Humans consistently err in their percepts of rotational motion viewed through an aperture. Such errors provide insight into the constraints observers use to interpret retinal images. In the 1st of 2 experiments, Ss consistently perceived the fixed center of rotation for an unmarked line viewed through an aperture as located on the line, regardless of its actual location. Accuracy greatly improved with visible line endings. This finding was extended to explain why a square appears nonrigid when it rotates behind a partial occluder. This illusion may result from observers misperceiving the center of rotation of the unmarked square sides. In this situation, Ss seemed unable to apply an object rigidity constraint across apertures. These findings support a conceptualization of the visual system in which consistent local information must be clearly present before prior knowledge can be used to interpret retinal stimulation.

Attention