PubMed Health⌕ Search

Biomedical subjects

M Sklansky

Publications and source records attributed to M Sklansky.

7 recordsLinked to original sources

Prenatal screening for congenital heart disease using real-time three-dimensional echocardiography and a novel 'sweep volume' acquisition technique.

OBJECTIVES: Conventional prenatal screening for congenital heart disease (CHD) involves a time-consuming and highly operator-dependent acquisition of the four-chamber view and outflow tracts. By acquiring the entire fetal heart instantaneously as a single volume, real-time three-dimensional echocardiography (RT3DE) may facilitate fetal cardiac screening. METHODS: Four reviewers, each experienced with fetal cardiac imaging, blindly and independently evaluated a single cardiac volume from each of 18 fetuses (11 normal, seven with CHD). Two-dimensional echocardiography served as the gold standard. Three-dimensional evaluation of each fetus included a series of volume acquisitions lasting 2-6 s each. A 'sweep volume' technique was developed to fit larger hearts into a single non-gated volume. RESULTS: RT3DE had a high sensitivity for detecting CHD (93%), with only a single case being missed by two observers. Specificity for CHD was low (45%), with a high rate of 'cannot determine' responses and false positive artifacts. CONCLUSIONS: These preliminary results suggest that RT3DE has the potential to function as a screening tool for fetal heart disease. However, artifacts must be recognized and minimized, resolution must improve, and substantial training will be necessary prior to widespread clinical use.

Artifacts↗

Neonatal euthanasia: moral considerations and criminal liability.

Despite tremendous advances in medical care for critically ill newborn infants, caregivers in neonatal intensive care units still struggle with how to approach those patients whose prognoses appear to be the most grim, and whose treatments appear to be the most futile. Although the practice of passive neonatal euthanasia, from a moral perspective, has been widely (albeit quietly) condoned, those clinicians and families involved in such cases may still be found legally guilty of child abuse or even manslaughter. Passive neonatal euthanasia remains both a moral dilemma and a legal ambiguity. Even the definition of passive euthanasia remains unclear. This manuscript reviews the basic moral and legal considerations raised by the current practice of neonatal euthanasia, and examines the formal position statements of the American Medical Association and the American Academy of Pediatrics. The paper concludes by emphasising the need, at least in the United States, to clarify the legal status of this relatively common medical practice.

Child Abuse↗

Intrapericardial teratoma in a twin fetus: diagnosis and management.

BACKGROUND: A rare cause of hydrops fetalis, intrapericardial teratoma is invariably associated with a pericardial effusion. In fetal life, the effusion or mass effect may cause cardiac tamponade, hydrops, and death. After delivery, ventilation and cardiac output may be compromised. CASE: One fetus of twins was diagnosed at 20 weeks' gestation with an intrapericardial teratoma. The affected twin underwent two intrauterine pericardiocentesis and had the tumor resected after delivery at 35 weeks' gestation. One year later, both twins are alive and well and have no evidence of tumor recurrence. CONCLUSION: Pericardiocentesis for tamponade secondary to a fetal intrapericardial teratoma, even when complicating a twin pregnancy, may prevent fetal death and allow delay of delivery until adequate fetal lung maturity has been achieved.

Adult↗

Three-dimensional echocardiographic evaluation of fetal heart anatomy and function: acquisition, analysis, and display.

The purpose of this work was to assess the functional dynamics and anatomy of the cardiac chambers and great vessels in the fetus (18 to 36 weeks) using in utero three-dimensional ultrasonographic imaging. Fifteen patients were studied using conventional two-dimensional sonographic equipment incorporating a position sensor attached to the transducer and a graphics workstation. Sonographic image data were acquired at 30 images per second and required less than 30 seconds per data set. Fetal heart rate and time in the cardiac cycle were determined and used to synchronize image data for reprojection into a volume at the appropriate part of the cardiac cycle. Volume data were analyzed, rendered, and displayed interactively. Three-dimensional sonographic volume data demonstrated fetal cardiac anatomy from multiple orientations and showed the myocardium, valves, ventricles, and atria clearly. The images showed good correlation with currently available embryologic-anatomic-pathologic data. Dynamic and spatial relationships among chambers, valves, and great vessels were readily appreciated. Three-dimensional sonographic imaging of the fetal heart provides both anatomic and functional information regarding the valves, myocardium, great vessels, and chamber dynamics. Interactive three-dimensional cinegraphic display enhances visualization of cardiac anatomy, which can be difficult to appreciate with two-dimensional methods. The methods presented in this work demonstrate the feasibility of three-dimensional fetal echocardiography.

Aorta↗

Advances in fetal cardiac imaging.

During the past 25 years, two-dimensional imaging of the fetal heart has evolved into a sophisticated and widely practiced clinical tool, but most heart disease still goes undetected until sometime after birth, despite routine fetal ultrasound evaluations. Over the next 25 years, tremendous advances in fetal cardiac imaging, including three-dimensional imaging, promise to revolutionize both the prenatal detection and diagnosis of congenital heart disease. Image resolution continues to improve year after year, allowing earlier (10-15 week) visualization of the fetal heart, as well as the detection of subtle valvar abnormalities that may progress to serious forms of ventricular hypoplasia at term. However, fetal cardiac imaging remains constrained by limited sonographic windows. To improve the prenatal detection of congenital heart disease, outflow tracts are increasingly included along with the routine screening four-chamber view. However, while the four-chamber view resides within a single plane, lending itself to tomographic evaluation with two-dimensional ultrasound, the outflow tracts (and most forms of congenital heart disease) do not reside within a single plane. For these and other reasons, three-dimensional imaging of the fetal heart ultimately may improve the detection of outflow tract abnormalities, and facilitate comprehension of complex forms of congenital heart disease. Finally, other imaging modalities, including but not limited to Doppler tissue imaging and magnetic resonance imaging, continue to evolve and to complement two- and three-dimensional sonographic imaging of the fetal heart. As a result of these ongoing advances in the prenatal detection and assessment of congenital heart disease, these are exciting and glorious times for the field of fetal cardiac imaging.

Diagnosis, Differential↗

A comparison of fetal echocardiography in university and health maintenance organization settings.

Fetal echocardiographic findings, and decisions to continue or to terminate affected pregnancies, may differ between university (UNIV) and health maintenance organization (HMO) settings. The aim of this study was to review the fetal echocardiographic experience at a combined university/health maintenance organization program over a 4-year period. Imaging and counseling for affected pregnancies were provided by the same, single investigator at both sites. Out of a total of 1382 studies (940 UNIV, 442 HMO), 127 abnormals were identified (94 UNIV, 33 HMO). Among the 127 pregnancies with fetal heart disease, 24 (19%) underwent elective termination, 16% at UNIV and 27% at HMO (p = 0.2). Mean gestational age at the time of diagnosis was 25.2 weeks at UNIV compared with 22.3 weeks at HMO (p = 0.002). At UNIV, only 51% of diagnoses were made before 24 weeks compared with 79% at HMO (p = 0.003). Screening fetal sonograms, performed between 18 and 20 weeks on every pregnancy at HMO but not at UNIV, enabled earlier detection of congenital heart disease (CHD) and allowed more women with severely affected pregnancies the option to terminate. In both settings, indications with the highest yields for CHD included a right-sided stomach, abnormal four-chamber view, sustained bradycardia, abnormal fetal karyotype, fetal omphalocele, and maternal indomethacin. An echogenic reflector was identified in 86 pregnancies (7%) and did not represent a risk factor for CHD. No major differences in CHD were found between UNIV and HMO. In summary, this study found a significantly earlier diagnosis of CHD at HMO than at UNIV. This discrepancy between programs may explain, at least in part, the trend toward a higher frequency of decisions to terminate affected pregnancies at HMO than at UNIV, despite similar fetal findings.

Abortion, Induced↗