Monte Carlo dose calculations for radiotherapy machines: Theratron 780-C teletherapy case study.

The Monte Carlo transport code MCNP was used to simulate the photon beam from a Theratronics 780-C cobalt therapy unit and to calculate some dose-dependent parameters as functions of field size. The simulation process has included the source capsule, collimators (fixed and adjustable), lead in the unit head, and the field sizes as ranged from 5 x 5 to 35 x 35 cm2. Calculations have been carried out in a water phantom at a fixed source-surface distance of 80 cm. Detailed simulation of the major components of the therapy unit made it possible to calculate the effects of each unit component on the photon spectrum at the phantom surface. Percentage depth dose and peak scatter factor were evaluated for various field sizes. And tissue-air ratios were also determined for a field size of 10 x 10 cm2, as a function of depth down to 30 cm. To test the accuracy of the calculated results, they were compared with the published data of the British Journal of Radiology (BJR) suppl. 25 and good agreement between measurements and calculations has been obtained. Deviations typically were found to be of the order of 1%.

Air↗

Impact of different pollutant sources on Shiraz air pollution using SPM elemental analysis.

Weekly average suspended particulate matter (SPM) concentrations were measured in four locations in Shiraz, Iran. Sampling was carried out from July 1999 and continued until July 2000. Instrumental neutron activation analysis (INAA) and atomic absorption spectrometry (AAS) methods were employed to obtain the weekly concentrations of Pb, Br, V, Ca, Al, Fe, Cu, Cr, Mn, Sc and Zn. The mean annual concentrations (in microg/m(3)) of 11 elements were found to be: Pb 0.545 (+/- 33.8%), Br 0.413 (+/- 34.1%), V 0.009 (+/- 28.2%), Ca 13.36 (+/- 24.5%), Al 2.56 (+/- 46.3%), Fe 2.62 (+/- 38.7%), Cu 0.122 (+/- 41.4%), Cr 0.015 (+/- 35.8%), Mn 0.053 (+/- 35.5%), Sc 0.0008 (+/- 37.5%) and Zn 0.085 (+/- 25.2%). The results of the study show that vehicle (traffic) pollution in Shiraz is higher than WHO and EPA standards and natural and industrial pollution is exceeding international guidelines in some seasons. The findings of the study confirm that the nearby cement factory has a major pollution impact on Shiraz air.

Air Pollutants↗

Gamma irradiator dose mapping simulation using the MCNP code and benchmarking with dosimetry.

The Monte Carlo transport code, MCNP, has been applied in simulating dose rate distribution in the IR-136 gamma irradiator system. Isodose curves, cumulative dose values, and system design data such as throughputs, over-dose-ratios, and efficiencies have been simulated as functions of product density. Simulated isodose curves, and cumulative dose values were compared with dosimetry values obtained using polymethyle-methacrylate, Fricke, ethanol-chlorobenzene, and potassium dichromate dosimeters. The produced system design data were also found to agree quite favorably with those of the system manufacturer's data. MCNP has thus been found to be an effective transport code for handling of various dose mapping excercises for gamma irradiators.

Journal Article↗

Borehole parametric study for neutron induced capture gamma-ray spectrometry using the MCNP code.

The MCNP Monte Carlo code has been used to simulate neutron transport from an Am-Be source into a granite formation surrounding a borehole. The effects of the moisture and the neutron poison on the thermal neutron flux distribution and the capture by the absorbing elements has been calculated. Thermal and nonthermal captures for certain absorbers having resonance structures in the epithermal and fast energy regions such as W and Si were performed. It is shown that for those absorbers having large resonances in the epithermal regions when they are present in dry formation or when accompanied by neutron poisons the resonance captures may be significant compared to the thermal captures.

Journal Article↗

Estimation of the genetically significant dose from diagnostic X-ray procedures in the Islamic Republic of Iran.

The genetically significant dose from diagnostic X-ray sources has been estimated. Age and sex distribution was based on a survey of 13,100 patients. Dosimetry was performed on patients and on an equivalent-man Rando phantom. Child-expectancy factors were estimated from the census results of fertility and mortality rates. The GSD value for the diagnostic procedures to the Iranian population was estimated to be 9.2 mrem/yr in 1980.

Adolescent↗