PubMed Health⌕ Search

Biomedical subjects

M Soltys

Publications and source records attributed to M Soltys.

10 recordsLinked to original sources

Methods for displaying intracerebral vascular anatomy.

We are developing three-dimensional imaging methods to portray vascular anatomy better, including noise-free display of vessels extracted from 3-D data sets, tree-based display, and reconstruction of angiographic data (preliminary work has resulted in the successful reconstruction of aneurysms from angiographic data). Fast, interactive display permits real-time manipulation of viewing orientation.

Computer Systems↗

Improving treatment planning accuracy through multimodality imaging.

PURPOSE: In clinical practice, physicians are constantly comparing multiple images taken at various times during the patient's treatment course. One goal of such a comparison is to accurately define the gross tumor volume (GTV). The introduction of three-dimensional treatment planning has greatly enhanced the ability to define the GTV, but there are times when the GTV is not visible on the treatment-planning computed tomography (CT) scan. We have modified our treatment-planning software to allow for interactive display of multiple, registered images that enhance the physician's ability to accurately determine the GTV. METHODS AND MATERIALS: Images are registered using interactive tools developed at the University of North Carolina at Chapel Hill (UNC). Automated methods are also available. Images registered with the treatment-planning CT scan are digitized from film. After a physician has approved the registration, the registered images are made available to the treatment-planning software. Structures and volumes of interest are contoured on all images. In the beam's eye view, wire loop representations of these structures can be visualized from all image types simultaneously. Each registered image can be seamlessly viewed during the treatment-planning process, and all contours from all image types can be seen on any registered image. A beam may, therefore, be designed based on any contour. RESULTS: Nineteen patients have been planned and treated using multimodality imaging from November 1993 through August 1994. All registered images were digitized from film, and many were from outside institutions. Brain has been the most common site (12), but the techniques of registration and image display have also been used for the thorax (4), abdomen (2), and extremity (1). The registered image has been an magnetic resonance (MR) scan in 15 cases and a diagnostic CT scan in 5 cases. In one case, sequential MRs, one before treatment and another after 30 Gy, were used to plan patient's initial fields and boost, respectively. Case illustrations are shown. CONCLUSIONS: We have successfully integrated multimodality imaging into our treatment-planning system, and its routine use is increasing. Multimodality imaging holds out the promise of improving treatment planning accuracy and, thus, takes maximum advantage of three dimensional treatment planning systems.

Humans↗

Three-dimensional reconstruction of intracranial vessels from biplane projection views.

The three-dimensional (3D) reconstruction of intracerebral vessels from two-dimensional (2D) projection views is an important clinical problem that, so far, has eluded solution. This report describes a new approach that uses projection images to build arterial trees progressively from an underlying 3D network, using a new method to pair shadow images on widely separated projection views. As a test of our general methodology, we have reconstructed a middle cerebral arterial tree from two projection views of a magnetic resonance dataset and have tested the accuracy of reconstruction against the original 3D dataset. This report describes the general approach to 3D vascular reconstruction and the computer program used to perform the final reconstruction step. The results suggest that accurate, 3D reconstruction of intracranial vessels is indeed possible from as few as two projection views.

Cerebral Arteries↗

A New Technique for CT/MR Fusion For Skull Base Imaging.

This paper presents our initial experience utilizing a new technique which allows CT and MR image fusion in patients with skull base lesions. Eleven patients with a variety of skull base lesions underwent CT and MR imaging prior to surgery. Both sets of images were coregistered using customized software. The CT and MR data sets were then combined and viewed in a single interactive image formar using a high-speed graphic computing system. Image fusion allowed simultaneous visualization of the bony skull base anatomy (CT) and detailed soft tissue anatomy (MR) using a single image format. Combining both modalities was felt to provide a better assessment of the extent of lesions and improve understanding of their relationship to adjacent bony and neurovascular anatomy. Specifically, image fusion enhanced awareness of location of skill base lesions with respect to the cavernous sinuses. Gasserian ganglia, carotid arteries, and jugular foramina. For tumors arising within the internal auditory canal (IAC), fused images allowed better delineation of the lateral aspect of the lesion with respect to the fundus of the IAC. Thus, fusion of CT and MR studies provides a unique image format which has advantages over single modality display. We believe image fusion is beneficial for surgical planning and for treatment planning of complex skull base malignancies treated with radiotherapy.

Journal Article↗

Three-dimensional reconstruction of a bullet path: validation by computed radiography.

Three-dimensional visualization is an important tool in the evaluation and demonstration of injury. Creating convincing graphics, however, requires strict distinction between illustrative and reconstructive visualizations and a method of validation. We present a case in which we used a radiation-planning tool to provide a 3-dimensional illustrative visualization of a contact gunshot wound to the head, and validated the result by comparing computed radiographs with radiographs taken at autopsy. We discuss the use of visualization tools for data exploration in forensic pathology.

Adult↗

An innovative approach to telemetry monitoring.

To use staff more effectively on a medical telemetry unit, nurses collaborated with clinical engineers to incorporate a commercially available pocket pager with a dysrhythmia detection system. Nurses carry a pocket pager which beeps and displays the patient's room number when a dysrhythmia is detected. This system eliminates the need for a telemetry monitor watcher and provides nurses with ongoing information about their patients. It also created an annual savings of approximately $130,000.

Arrhythmias, Cardiac↗

Codes and standards.

Explore the source record for details and available documents.

Equipment and Supplies↗

Radiofrequency field surveys in hospitals.

The authors surveyed levels of radiofrequency (RF) fields in the frequency range 0.1-1,000 MHz in four hospitals in the Philadelphia area, to obtain background information related to the possible interference of radiofrequency fields with medical equipment. Two large center-city hospitals, a regional county hospital, and two suburban hospitals were surveyed. Measurements were made at six to 12 sites in each hospital, in each of the three frequency bands. More limited additional measurements were conducted in a fifth hospital as well. Sites were selected to include areas where strong RF signals from transmitting antennas might be expected to be present (e.g., locations close to windows in upper stories of buildings near paging antennas) as well as other representative sites in the hospital. The median RF field strengths were quite low (0.1-0.5 V/m), but at specific locations the RF signals from broadcast sources exceeded 1 V/m. Much stronger fields were recorded close to electrosurgical units and hand-held transmitters (cellular telephones and UHF transceivers).

Electromagnetic Fields↗

Dialysis.

Explore the source record for details and available documents.

Equipment Design↗