PubMed Health⌕ Search

Biomedical subjects

M Soylak

Publications and source records attributed to M Soylak.

10 recordsLinked to original sources

Speciation of Cr(III) and Cr(VI) after column solid phase extraction on Amberlite XAD-2010.

A speciation procedure for Cr(III) and Cr(VI) based on column solid phase extraction on Amberlite XAD-2010 and flame atomic absorption spectrometry combination. Cr(VI) was quantitatively recovered on Amberlite XAD-2010 resin at pH range of 2.0-3.0 as its diethyldithiocarbamate complex, while the recoveries of Cr(III) was below 5%. The influences of the various parameters including amounts of the reagents, eluent type and its volume, sample volume, etc., on the quantitative recoveries were examined. The interference of matrix and coexistent elements for method were studied. The detection limit (corresponding to three times the standard deviation of the blank) and the enrichment factor for Cr(VI) were found to be 1.28 microg/L and 25, respectively. To verify the accuracy of the method, drinking water certified reference material (CRM-TMDW-500) was analyzed and the results obtained were in good agreement with the certified value. The proposed method has been successfully applied to the speciation of Cr(III) and Cr(VI) in water samples and preconcentration of total chromium in environmental samples.

Chromium↗

Solid phase extraction method for selective determination of Pb(II) in water samples using 4-(4-methoxybenzylidenimine) thiophenole.

A sensitive and selective extractive preconcentration procedure for the determination of traces of lead in water samples has been developed. An alumina-sodium dodecyl sulfate (SDS) coated modified with 4-(4-methoxybenzylidenimine) thiophenole (MBITP) was used for preconcentration and determination of Pb(II) by flame atomic absorption spectrometry. Lead was adsorbed quantitatively on modified column due to its complexation with MBITP and quantitatively eluted using 5 mL 1 mol L(-1) nitric acid in acetone. The effects of parameters such as pH, amount of solid phase, amount of MBITP, flow rate, type and concentration of eluting agent were examined. The effect of interfering ions on the determination of Pb(II) was also investigated. The response of proposed method is linear in the concentration range 0.05-1.2 microg mL(-1) of Pb(II). The limit of detections (3S.D.(b)/m, n=4) and relative standard deviations (n=11) are 1.6 ng mL(-1) and 0.9%, respectively. The presented procedure was successfully applied for determination of lead content in real samples such as river, spring, waste and drinking water.

Benzene Derivatives↗

A new preconcentration and separation method for flame atomic absorption spectrometric determinations of some trace metal ions on a Diaion HP-20 column.

A preconcentration/separation method for determination of Cr(III), Cd(II), Bi(III) and Co(II) has been proposed. The analytes were adsorbed on a column filled Diaion HP-20 resin as metal-8-hydroxiquinoline complexes and desorbed from the column by using 10 ml of 1M HNO3 in acetone. The influences of some analytical parameters such as pH, amounts of oxine, type of eluent etc on the recoveries of chromium, cadmium, bismuth and cobalt were discussed. Effects of the various alkaline salts on the recoveries of the investigated ions were also examined. The method was applied for the determination of Cr(III), Cd(II), Bi(III) and Co(II) contents of table salt samples, some chemical grade alkaline salts produced in Turkey and a stream sediment standard reference material sample (GBW 07309) with satisfactory results (recoveries > 95%, relative standard deviations < 9%). The limit of detection for analyte ions (3s, N = 20) was between 23-305 ng/g.

Environmental Monitoring↗