Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner.

We observed early failure and radiographic signs of accelerated wear as early as one to three years after insertion, without cement, of a metal-backed acetabular component with a liner made of Hylamer (DePuy). This finding prompted us to review a larger cohort of patients in whom that liner had been used. Two hundred and thirty-three components with a Hylamer liner, evaluated at a minimum of two years, had a mean rate of wear of 0.27 millimeter per year compared with 0.12 millimeter per year for a contemporaneous group of fifty acetabular cups with a conventional ultra-high molecular weight polyethylene liner made by another manufacturer. At a mean of 3.2 years, we found a significant difference (p < 0.000000006) between the mean rate of wear (0.20 millimeter per year) when the Hylamer liner articulated with a DePuy modular cobalt-chromium femoral head and the mean rate (0.29 millimeter per year) when the liner articulated with an Osteonics modular cobalt-chromium femoral head. Radiographic evaluation revealed a significant correlation between the total linear wear and the prevalence of osteolytic lesions (r2 = 0.76, linear regression analysis). We found that wear of 1.5 millimeters or more could be detected by the unaided eye. Because of the positive correlation between osteolysis and wear of 1.5 millimeters or more, we defined a hip with a liner that had that amount of wear as a hip at risk. We concluded that the wear characteristics of a Hylamer liner in vivo are inferior to those of a conventional ultra-high molecular weight polyethylene liner. Also, the rate of wear of the liner is greater when the femoral head is from a manufacturer other than DePuy. A patient who has a total hip replacement that includes a Hylamer liner should be monitored frequently for signs of wear and osteolytic changes. Additional investigations, with longer durations of follow-up and larger populations, are needed to understand fully the importance of our findings.

Adult↗

Myofibroblasts in the healing lapine medial collateral ligament: possible mechanisms of contraction.

The specific objective of this study was to determine the chronology of the appearance of the myofibroblast in the healing ligament. The overall goal of our work is to elucidate the cellular mechanism of contraction in this tissue. The myofibroblast has been found to be responsible for wound contraction in many tissues and to be the cause of the contracture in several pathological conditions. This cell type contains the actin isoform previously thought to be unique to smooth muscle cells and displays certain characteristic features at the ultrastructural level. In 26 New Zealand White male rabbits, the right medial collateral ligament was transected, whereas the left medial collateral ligament received a sham operation. The central third of the ligament (ligament scar tissue) was evaluated at 2, 3, 6, 8, 10, and 12 weeks postoperatively by immunohistochemical techniques, transmission electron microscopy, and Western blot analyses. Three other rabbits served as anatomic controls. During the early reparative phase (2 and 3 weeks after transection), there was an increase in the number of cells containing alpha-smooth muscle actin as well as augmentation of the alpha-smooth muscle actin content within each cell--a finding attributed to smooth muscle cells and pericytes associated with neovascularity. No myofibroblasts were detected at this stage, immediately postoperatively, or in the sham-operation controls. Ligaments in the remodeling phase of healing (6, 8, 10, and 12 weeks) exhibited alpha-smooth muscle actin in fibroblasts (myofibroblasts) as well as in vascular pericytes and smooth muscle cells. During this stage of healing, transmission electron microscopy demonstrated an increase in the number of cells displaying myofibroblastic features. It was estimated that at 12 weeks of healing 10% of the cells at the site of injury were myofibroblasts. This is the first definitive finding of myofibroblasts in the injury site of the healing ligament, to our knowledge. The appearance of myofibroblasts in the 6-12 week healing period, the interval during which the ligament has been shown to contract in studies by other investigators, is a rationale for a hypothesis that a cellular contractile apparatus comprising alpha-smooth muscle actin (i.e., the myofibroblast) may contribute to the recovery of original ligament length (and normal in situ strain).

Actins↗

Healing of chondral and osteochondral defects in a canine model: the role of cultured chondrocytes in regeneration of articular cartilage.

In this study a canine model was developed to investigate the nature of early healing responses to both chondral and osteochondral defects and to evaluate the tissue regenerative capacity of cultured autologous chondrocytes in chondral defects. The healing response to surgically created chondral defects was minor, with little cellular infiltration. In contrast, osteochondral defects exhibited a rapid cellular response, resulting ultimately in the formation of fibrous tissue. The lack of significant cellular activity in chondral defects suggests that an evaluation of the capacity of cultured autologous chondrocytes to regenerate articular cartilage is best studied in chondral defects using the canine model. When dedifferentiated cultured articular chondrocytes were implanted into chondral defects, islands of type II collagen staining were demonstrated in the regenerative tissue within 6 weeks. The relatively early expression of cartilage specific markers by the implanted chondrocytes, coupled with the inability of untreated chondral defects to repair or regenerate, demonstrates the utility of the canine model in evaluating novel materials for cartilage repair and regeneration.

Animals↗

Pre-conditioning and dual constant composition dissolution kinetics of pulsed laser deposited hydroxyapatite thin films on silicon substrates.

The kinetics of dissolution of pulsed laser deposited crystalline and amorphous thin films of hydroxyapatite on silicon substrates were measured at 37 degrees C and a pH value of 6.5 using the dual constant composition method. Solutions in which the pulsed laser deposited films were pre-conditioned (0.15 M NaCl) remained undersaturated or slightly supersaturated with respect to hydroxyapatite after equilibrium was reached, indicating only a very small coating release and the absence of re-precipitation on the surfaces. The amorphous films released more calcium and phosphate during pre-conditioning than the more crystalline films. Dual constant composition dissolution rates decreased as film crystallinity increased. The film with the lowest dissolution rate (approximately one sixth that of a crystalline film deposited using a hydroxyapatite powder target) was fabricated using a human tooth as the laser target. During pre-conditioning of plasma-sprayed coatings, more calcium and phosphate were released than for pulsed laser deposited films, and dual constant composition dissolution rates were much higher.

Calcium Phosphates↗

Degradation potential of plasma-sprayed hydroxyapatite-coated titanium implants.

The purpose of this study was to develop an analytical method for evaluating the dissolution behavior of plasma-sprayed hydroxyapatite (HAP) coatings. Six commercially available and clinically used coatings applied to nonporous titanium coupons according to their respective specifications for orthopedic devices were used in this study. Dissolution behavior was monitored by first preconditioning the implant in 0.15 mol L-1 sodium chloride solution at 37 degrees C until either equilibrium or the desired change in solution hydrogen and calcium ion concentrations had been reached. In the second step, the implants were subjected to dual constant composition (DCC) dissolution under conditions of controlled undersaturation. Results indicate that the dissolution rates of the HAP coatings may differ by as much as a factor of 5 despite the fact that analytical techniques, including X-ray diffraction and FTIR, indicate no change in crystallinity or composition of the coatings before and after the solution treatment. These results indicate that HAP coatings from different sources react very differently when placed in the same local aqueous environment. However, more work will be necessary before these in vitro results can be used to predict in vivo behavior.

Alloys↗

Pore strain behaviour of collagen-glycosaminoglycan analogues of extracellular matrix.

Mechanical properties of a highly porous collagen-glycosaminoglycan (CG) analogue of extracellular matrix were investigated. The stress-strain behaviour of the matrices displayed the typical concave-up shape characteristic of porous materials and soft tissues. Deformation behaviour of the material was further investigated using novel methodology to determine material strains at the micrometre level. Central to the methodology was the use of scanning electron microscopy (SEM) in conjunction with a digital image analyser. The method for strain determination at the micrometre level was verified by comparison with measurement of surface strain using an optical method. An unexpected finding in these materials is that Poisson's ratio varies with engineering strain. A geometrical/mathematical model was developed to explain this behaviour. These results encourage further investigation of the mechanical properties of these materials, in order to provide important insights into the physical microenvironment in which cells reside.

Biocompatible Materials↗

A human homolog of the S. cerevisiae HIR1 and HIR2 transcriptional repressors cloned from the DiGeorge syndrome critical region.

The DiGeorge syndrome (DGS) is a developmental disorder affecting derivatives of the third and fourth pharyngeal pouches. DGS patients present an interstitial deletion in one of their two chromosomes 22. Cosmid DAC30 was mapped to the DGS smallest critical region. Iterative cDNA library screening initiated with a DAC30 gene fragment candidate yielded a cDNA contig whose assembled nucleotide sequence is consistent with the widely transcribed, 4.2-4.4 kb long, messengers detected by northern analysis. The deduced protein sequence, 1017 amino acids in length, entirely encompasses the 766 amino acids previously designated as TUPLE1. The completed protein has been renamed HIRA because it contains various features matching those found in HIR1 and HIR2, two repressors of histone gene transcription characterized in the yeast Saccharomyces cerevisiae. Strikingly alike in their N-terminal third, HIRA and HIR1 contain seven copies of the WD repeat, a motif implicated in protein-protein interactions, suggesting that they might define a new subfamily of functionally homologous proteins. The remainder of the human polypeptide highly resembles a corresponding fragment in HIR2. We propose that HIRA, alone, could have a part in mechanisms of transcriptional regulation similar to that played by HIR1 and HIR2 together. The presence of a single copy of the HIRA gene in DGS patients possibly accounts for some of the abnormalities associated with this syndrome.

Amino Acid Sequence↗

Distal loss of femoral bone following total knee arthroplasty. Measurement with visual and computer-processing of roentgenograms and dual-energy x-ray absorptiometry.

The changes in bone-mineral content in the distal aspect of a cadaveric femur that had been prepared for insertion of the femoral component of a total condylar knee prosthesis were evaluated with visual inspection and computer-processing of roentgenograms and with dual-energy x-ray absorptiometry. Seventeen small slices of bone, each three millimeters wide, were removed so that, finally, 89 per cent of the bone was lost from the distal femoral metaphysis. Standardized lateral roentgenograms of the specimen were made with use of a reference step-wedge of hydroxyapatite, and dual-energy x-ray absorptiometry studies were performed with the x-ray beam tangential to the interface. The roentgenograms were digitized and the bone mineral was measured with use of computer analysis. Dual-energy x-ray absorptiometry was performed with and without the femoral prosthesis in place, in order to determine the effect of the metallic prosthesis on the accuracy of the measurement. A bone loss of 25 per cent or more was identified visually by all five of the readers 100 per cent of the time; losses of 20 to 24 per cent, 15 to 19 per cent, 10 to 14 per cent, and 3 to 9 per cent were correctly identified 92, 75, 66, and 59 per cent of the time, respectively. The measurements of bone-mineral content that were obtained from the digitized roentgenograms were linearly correlated with the actual bone-mineral content (the ash content) (r = 0.97, p < 0.001) and were three times more accurate than the visual readings. The determinations of bone-mineral content with dual-energy x-ray absorptiometry correlated highly with the ash content (r = 1.00, p < 0.001) and were seven times more accurate than the visual readings. There was only a 4 per cent difference between the measurements with dual-energy x-ray absorptiometry made with the prosthesis in place and those made without it in place (p < 0.01). Dual-energy x-ray absorptiometry was the most accurate of the three methods and could detect the smallest experimentally created loss; computer-processing and visual-processing of roentgenograms detected losses of 8 per cent or more and 25 per cent or more, respectively. Dual-energy x-ray absorptiometry and computer-processing of the roentgenograms quantified the bone loss, while visual-processing could detect only the presence or absence of bone loss.(ABSTRACT TRUNCATED AT 400 WORDS)

Absorptiometry, Photon↗

Anorganic bovine bone and ceramic analogs of bone mineral as implants to facilitate bone regeneration.

A number of approaches have directed toward the development of a substance that can substitute for allogeneic bone for grafting procedures. Synthetic HA ceramic materials are limited in being able to serve as analogs of bone mineral for use as implants to facilitate bone regeneration. HA ceramics do not replicate the chemistry and crystalline structure of natural bone mineral. An alternative approach has been to deorganify bovine bone to produce bone mineral in forms that can be employed as implants.

Animals↗

Hypoplastic left-heart syndrome Norwood operation, transplantation, or compassionate care.

In our current practice, either the Norwood operation or heart transplantation must be considered reasonable options for neonates born with hypoplastic left-heart syndrome. Clearly some children with this otherwise lethal defect have been helped by both approaches. Is it yet, in 1993, appropriate to delete compassionate care from our group of options? Despite all the advances of the past decade, we are not at the point where we can declare hypoplastic left-heart syndrome "cured" even for the survivors of the Norwood operation or heart transplantation. Compassionate care (including withdrawal of prostaglandin E1) is still appropriate for those families who feel that the chance of success and the quality of life are not great enough to justify the challenges the infants and their families must face. Clearly as technical modifications are made in the Norwood operation and as advances are made in transplantation biology, the number of families who choose compassionate care will decrease.

Heart Defects, Congenital↗

Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty.

The objective of this study was to establish the role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty. We developed a three-dimensional finite element model of an intact human femur and the same femur with a conventional collared straight-stem femoral component. Using published data, we defined two sets of loading conditions: one that represented three phases of gait, and one that represented four different extreme loads. The four extreme loads were based on the peak joint contact forces that occur during stair ascent and isometric contraction of various muscle groups. The model was analyzed with three different material properties for the prosthesis, including cobalt-chromium alloy, titanium alloy, and a carbon fiber-reinforced polymer (CFRP) laminate. We assumed that the implant was stable, with rigid bonding, collar contact, and no cement. To address femoral component loosening, we examined the shear stresses at the implant-bone interface; to address adaptive bone remodeling, we examined the principal stresses in the supporting cortical bone relative to those in the intact femur. Our analyses of the various loading conditions demonstrated large out-of-plane bending movements and torsional moments, especially for the load representing stair ascent. Based on stepwise multiple regressions, the maximum shear stresses at the implant-bone interface in the distal region were dependent on the total applied axial force and torsion; the maximum shear stresses in the proximal region were dependent on the axial component of the joint contact force alone. Reduction in the prosthesis stiffness, by substitution of the CFRP material properties, resulted in lower interface shear stresses at the distal end of the stem and higher interface shear stresses at the more proximal sections, consistent with the findings of others. We fit equations, based on composite beam theory, to the maximum implant-bone interface shear stresses and the cortical bone principal stresses as a function of the axial modulus of the prosthesis. These equations can be used to estimate the maximum stresses at the interface and in the cortical bone that would be predicted by similar models, for the same prosthesis constructed of alternative materials, relative to the stresses in the intact femur. The nonlinear nature of these relationships was such that the cortical bone stresses changed more rapidly, as a function of the prosthesis modulus, for lower values of elastic modulus, especially in the more proximal sections.

Biomechanical Phenomena↗

Synovium-like tissue from loose joint replacement prosthesis: comparison of human material with a canine model.

The formation of synovium-like tissue is a biological response to a loose joint replacement prosthesis. Histological examination of this tissue has shown a synovial lining with a predominance of fibroblasts and macrophages, some multinucleated giant cells, and dispersed particles from the implant. Previous studies have reported elevated interleukin 1 (IL-1), prostaglandin E2 (PGE2), and collagenase in this tissue. We developed a canine model for the loose cemented femoral stem. Tissue harvested from the canine model was compared with human tissue retrieved at revision arthroplasty. Histology showed synovium, similar to that observed around loose human prostheses, adjacent to the canine cement sheath. Cells were isolated from this tissue and incubated in culture medium with or without naproxen for 3 days. Aliquots of the conditioned media were tested in the thymocyte proliferation assay to determine IL-1-like activity. IL-1 beta levels in human cell-conditioned media were analyzed by enzyme-linked immunosorbent assay, and PGE2 levels were measured by radioimmunoassay (RIA) using a PGE2 RIA kit (New England Nuclear). Human tissue contained levels of IL-1 beta in the range of 150 to 7,040 pg/mL and PGE2 levels of 82 to 952 ng/mL. The canine specimens contained IL-1-like activity and significant amounts of PGE2 (76 to 1,720 ng/mL). Naproxen decreased PGE2 levels in vitro. This animal model provides the means to investigate the in vivo and in vitro activity of the synovial cells around loose total joint prostheses.

Adult↗

Biomaterial failure.

One conclusion that might be drawn from a review of the role of biomaterial failure in total hip arthroplasty is that the fracture, wear, and corrosion of materials often serve as the primary causes of failure of hip replacements. It is not yet possible, however, to conclude the prevalence or time course of these failures. We need to gain more knowledge about the properties of orthopedic biomaterials and the loading to which they are subjected during function. Judicious design and implementation of prostheses can serve to extend the serviceable life of an arthroplasty even with ongoing fracture, wear, and corrosion of biomaterials.

Biocompatible Materials↗

The biologic effects of implant materials.

The interaction between implant materials and the surrounding biological environment continues to be an area of intense research and clinical interest. This article presents the information presented in a symposium, held during the 36th Annual Meeting of the Orthopaedic Research Society, in which several important issues concerning the biologic effects of implant materials were discussed. These issues included the mechanisms by which implant materials are released to the surrounding tissues and the ways in which these tissues respond to implant materials. The problem of bone loss around cementless implants was discussed as a specific example of a biologic effect resulting in both bone remodelling and endosteal erosion.

Biocompatible Materials↗