PubMed Health⌕ Search

Biomedical subjects

M Srámek

Publications and source records attributed to M Srámek.

8 recordsLinked to original sources

FreeCall, a system for emergency-call-handling support.

This article describes a system for the optimization of the prehospital assessment of emergency, in cases involving thoraco-abdominal complaints and consciousness problems. This assessment is performed by nurses on the basis of a telephone interview at ambulance dispatch centers. The system has a body of biomedical and policy knowledge available to guide the interview and to provide advice.

Algorithms↗

Improvement of 3D visualization of the brain using anisotropic diffusion smoothing of MR data.

This paper deals with an iterative 3D smoothing of MR images acquired by fast 3D Flash sequences. The method explored, which is aimed at improving 3D visualization quality, uses the physical concept of anisotropic diffusion. A novel iteration stopping criterion is proposed and tested. The results of computer experiments with 3D smoothing, segmentation, and visualization using actual MR brain data are presented and discussed.

Algorithms↗

Telephone triage of cardiac emergency calls by dispatchers: a prospective study of 1386 emergency calls.

OBJECTIVES: To evaluate the handling of potential cardiac emergency calls by dispatchers, to determine their final diagnosis and urgency, and to determine the value of the main complaint in predicting urgency and the ability of the dispatchers to recognise non-urgent conditions. DESIGN: Prospective data collection and recording of main complaint of emergency calls placed via the 06-11 alarm telephone number with follow up to hospital when the patients were transported and the general practitioner when they were not. SETTING: Dispatch centres of the emergency medical services in Amsterdam (urban area) and Enschede (rural area). PATIENTS: 1386 consecutive adult subjects of emergency calls placed by citizens about chest problems or unconsciousness not caused by injury. MAIN OUTCOME MEASURES: Frequency of characteristics of the calls, outcome in diagnosis, and assessment of urgency. RESULTS: 69 (5%) patients were dead when the ambulance arrived. Diagnosis was established in 1071 patients (77%). The disorders most often reported were cardiac, with acute ischaemia in 15% of all subjects. In 28% of cases and for each presenting complaint no organic explanation was found. Overall 39% of all emergency calls were urgent; the urgency rate was lowest for calls for people with abdominal discomfort. Dispatchers correctly identified 90% of the non-urgent calls, but 55% of the calls that they identified as urgent proved to be non-urgent. CONCLUSION: Currently, direct dialling for an ambulance without the intervention of a general practitioner imposes a high work load on emergency systems and hospitals because triage by dispatchers is not sufficiently accurate. It may be possible to increase the accuracy of triage by developing and testing decision algorithms.

Acute Disease↗

Enzyme immunoassay to determine serum myoglobin in patients with acute myocardial infarction.

A method of "sandwich" enzyme immunoassay was developed for determination of human serum myoglobin with the use of myoglobin isolated from human myocardium and gammaglobulin fraction of a specific sheep antiserum labelled with horseradish peroxidase. The linear part of the calibration curve within the range of 0.08-2.2 nmol/l is suitable for accurate quantitative reading of myoglobin concentration. Intra- and interassay variation coefficients are 7% and 11.2%, respectively. A comparison of 100 serum samples assessed by means of commercially available RIA kit and by the given method revealed a correlation coefficient of 0.86.

Enzyme-Linked Immunosorbent Assay↗

The first clinical trial for determination of alpha 1 fetoprotein by means of Sevatest-ELISA AFP Kit (micro I).

At the Institute of Sera and Vaccines, Praha, was invented and tested on clinical samples a kit for detection and quantification of alpha 1 fetoprotein in human serum. It is a heterogeneous EIA on the "sandwich" principle. Rabbit antibody to alpha 1 fetoprotein (further AFP) was used for coating the solid surface and goat horse-radish peroxidase labelled antibody to AFP was used as the tracer. Microtitration plate of Czechoslovak manufacture (KOH-I-NOOR, Dalecín) type P with 96 wells was used as the solid phase. The range of an approximately linear part of the calibration curve was intentionally chosen between 10 and 400 ng/ml, since in this way it fills the detection gap in AFP determination between 10 and 200 ng/ml, which is, on the one hand, a physiological value of AFP in human serum and, on the other hand, the bottom limit of sensitivity of counter immunoelectrophoresis (CIEP). Attention was devoted both to reproducibility of the method, i.e. results of intra- and interassays, and comparability with other foreign ELISA Kits. According to the correlation analysis, the kit was ascertained to be very well comparable with kits of foreign provenance. The coefficient of variation (CV) for the interassays varied between 11 and 16% and for intraassays it equalled 15%.

Clinical Trials as Topic↗