PubMed Health⌕ Search

Biomedical subjects

M Strachan

Publications and source records attributed to M Strachan.

10 recordsLinked to original sources

Quality of life before and after intensive care.

Quality of life is often thought to be poor before and after intensive care unit admission. The aim of this study was to investigate changes in quality of life before and after intensive care. A prospective cohort study of 300 consecutive patients admitted to intensive care was performed in a Scottish Teaching Hospital. Quality of life was assessed premorbidly and 3, 6 and 12 months after intensive care admission for surviving patients using SF-36 as well as EQ-5D scores at 12 months. The median value for age was 60.5 years and for APACHE II score, 18. The mean length of stay was 6.7 days. SF-36 physical component scores decreased from premorbid values at 3 months (p = 0.05) and then returned to premorbid values at 12 months (p < 0.001). The mean physical scores were below the population norm at all time points but the mean mental scores were similar or higher than these population norms. Patients who died after intensive care discharge had lower quality of life scores than did survivors (all p < 0.01). Poor premorbid quality of life was demonstrated and appears to reduce after ICU discharge. For survivors there was a slow increase in physical quality of life to premorbid levels by the end of the first year but these remained lower than in the general population. ICU patients experience a considerable longer-term burden of ill health.

APACHE↗

Comparative value of dobutamine and adenosine stress in the detection of coronary stenosis with myocardial contrast echocardiography.

BACKGROUND: Controversy continues as to whether adenosine or dobutamine is the superior pharmacological stress agent for myocardial contrast echocardiography (MCE). METHODS AND RESULTS: We compared real-time MCE refilling curves and wall thickening during adenosine and dobutamine stress in 14 open-chest dogs with left anterior descending and left circumflex coronary artery stenoses that reduced hyperemia by 40% to 60% and 70% to 90% (mild and severe non-flow-limiting stenosis, NFLS) and resting flow by 10% to 30% and 35% to 50% (mild and severe flow-limiting stenosis, FLS). MCE was performed with low-energy imaging during Optison infusion. After high-energy bubble destruction, time-intensity data from risk beds were fitted for an exponential function as y=A(1-e(-)(bt)), from which the rate of intensity increase (b) and maximal plateau intensity (A) were derived. Although severe NFLS and greater stenoses decreased b with both dobutamine and adenosine, with mild NFLS it was reduced in 58% of animals with dobutamine versus 8% with adenosine. The absolute decrease in b, however, was greater for adenosine than dobutamine with FLS. The A parameter was decreased with both adenosine and dobutamine only with the most severe FLS. Wall thickening was decreased with dobutamine in 33% of animals with severe NFLS and in all animals with any FLS; with adenosine, in all with severe FLS. CONCLUSIONS: Both dobutamine and adenosine significantly reduce MCE refilling rates in the setting of severe stenosis and in the absence of contractile abnormalities. Dobutamine decreases refilling rate and wall thickening at a less reduced flow grade than adenosine, but adenosine produces a greater magnitude of change than dobutamine.

Adenosine↗

Accuracy and reproducibility of coronary flow rate assessment by real-time contrast echocardiography: in vitro and in vivo studies.

Real-time myocardial contrast echo (MCE) provides the potential to assess myocardial blood flow from time-intensity refilling curves after high-energy bubble destruction. This study validated the accuracy of this approach and the effect of specific examination variables and instrument settings on results. The effects of examination depth and angle as well as dynamic range, pulse repetition frequency, and line density were assessed with the use of in vitro incremental flow rates produced in an in vitro tissue phantom. In vivo recordings of real-time imaging with an infusion of a contrast agent (Optison) were obtained in 7 open-chest dogs with graded left anterior descending artery stenosis at baseline and during adenosine hyperemia, and were compared with flow probe measurements. After bubble destruction, time-intensity data were fitted to an exponential function, and the rate of intensity increase (b) and peak plateau intensity (A) were derived from refilling curves. In vivo real-time values for b, but not A, correlated closely with flow probe measures (r = 0.93). A similar correlation for b was observed in vitro (r = 0.98). The correlation between flow rate and b was influenced by several examination variables, including depth, angle, and instrument settings. Real-time MCE provides accurate quantification of coronary flow by assessing the rate of microbubble refilling. However, this parameter may be affected by several examination and instrument variables. Therefore, real-time MCE refilling measures are best applied by comparing baseline values with those of stress studies.

Animals↗

Strong commitment to traditional Protestant religious beliefs is negatively related to beliefs in paranormal phenomena.

Numerous studies have yielded small, negative correlations between measures of paranormal and "traditional religious beliefs". This may partly reflect opinions of Christians in the samples who take biblical sanctions against many "paranormal" activities seriously. To test this, 391 college students (270 women and 121 men) rated their beliefs in various paranormal phenomena and were classified as Believers, Nominal Believers, and Nonbelievers on the strength of their self-rated commitment to key biblical (particularly Protestant) doctrines. As predicted, Believers were significantly less likely than Nominal Believers or Nonbelievers to endorse reincarnation, contact with the dead, UFOs, telepathy, prophecy, psychokinesis, or healing, while the beliefs of Nominal Believers were similar to those of Nonbelievers. Substantial percentages of Nominal and Nonbelievers (30-50%) indicated at least moderate acceptance of the paranormal phenomena surveyed.

Adult↗

Real-time three-dimensional fetal echocardiography: initial feasibility study.

Real-time three-dimensional echocardiography acquires data as a volume rather than as a series of planar images, thereby obviating cardiac or respiratory gating and limiting artifacts generated by random motion. This study was undertaken to evaluate the feasibility of using real-time three-dimensional echocardiography to evaluate fetal cardiac anatomy and function. Ten human fetuses were evaluated in utero, four of whom had congenital heart disease. Freehand transabdominal scanning was performed on each pregnant woman using a real-time three-dimensional echocardiography system. Four volume clips at 20 volumes/s of duration 1.5 s each were obtained on each fetal heart and stored for off-line analysis. Data were displayed immediately as a series of four simultaneous planes, with the ability for the observer to manipulate the position of each plane within the acquired volume data set. Cardiac motion could be slowed, stopped, or viewed at its original speed. Most structures and views, as well as cardiac function, could be visualized consistently. Abnormal structures could be detected readily. Off-line analysis was rapid and easy. We conclude that fetal real-time three-dimensional echocardiography is a feasible, facile, and rapid new technique.

Echocardiography, Three-Dimensional↗

A family outbreak of hemolytic-uremic syndrome associated with verotoxin-producing Escherichia coli serotype O157:H7.

All five siblings (three boys and two girls, aged 1.5-9 years) in a family developed hemolytic-uremic syndrome associated with verotoxin-producing Escherichia coli O157:H7 at a lakeside vacation cottage during the fall of 1985. All five were hospitalized and made a full recovery. Both parents remained asymptomatic, and neither had evidence of this infection. In four children who were investigated prospectively, free verotoxin was still detectable in the stools for between 3 and 7 weeks. The prodromal diarrheal illness in the children occurred over a 10-day period. The epidemic curve was consistent with a point-source outbreak, but continuous exposure or person-to-person transmission could not be ruled out. The source of the infection was not identified.

Bacterial Toxins↗