PubMed Health⌕ Search

Biomedical subjects

M Stubgaard

Publications and source records attributed to M Stubgaard.

At least 19 recordsLinked to original sources

A two-compartment phantom for VOI profile measurements in small-bore 31P MR spectroscopy.

A two-compartment gel phantom for VOI profile measurements in volume-selective 31P spectroscopy in small-bore units is presented. The phantom is cylindrical with two compartments divided by a very thin (30 microm) polyethene film. This thin film permits measurements with a minimum of susceptibility influences from the partition wall. The phantom was used for evaluation of the volume selection method ISIS (image-selected in vivo spectroscopy). The position of the phantom was fixed in the magnet during the measurements, while the volume of interest (VOI) was moved stepwise over the border. The signal from the two compartments was measured for each position and the data were evaluated following differentiation. We have found this phantom suitable for VOI profile measurements of ISIS in small-bore systems. The phantom forms a useful complement to recommended phantoms for small bore-spectroscopy.

Biophysical Phenomena↗

Deuterium MR spectroscopy at 4.7 T. Quantification of tumour and subcutaneous tissue blood flow in animal models.

Deuterium MR spectroscopy was used for the determination of tissue blood flow (TBF). The tracer D2O was injected into the tissue of interest, and tracer washout was followed using a 4.7 T spectroscopy/imaging unit. Normal subcutaneous tissue in rats was studied, as well as tissue influenced by vasoactive agents (papaverine and adrenaline). The vasoactive agents introduced changes of 40% in TBF, compared with normal tissue. Normal tissue measurements were repeated using various D2O injection volumes (5-400 microliters). The injection volume 5 microliters gave TBF 11.7 +/- 2.0 ml/100 g.min (mean +/- 1 SD). This value was 40% higher than corresponding values observed at larger injection volumes (200-400 microliters). This injection volume effect is probably partly due to a capillary dilution caused by tracer administration, and partly related to the non-physiological deuterium signal decrease observed in dead rats. Blood flow measurements in human colon tumours implanted in nude mice showed a rather poor reproducibility, not improved by the use of a multiple site injection technique.

Adipose Tissue↗

The concentration of N-acetyl aspartate, creatine + phosphocreatine, and choline in different parts of the brain in adulthood and senium.

The fully relaxed water signal was used as an internal standard in a STEAM experiment to calculate the concentrations of the metabolites: N-acetyl aspartate (NAA), creatine + phosphocreatine (Cr + PCr), and choline (Cho) containing compounds in four different parts of the brain in two age groups of healthy volunteers (20-30 yr, n = 8) and (60-80 yr, n = 8). Furthermore, T1 and T2 relaxation time of the metabolites and signal ratios: NAA/Cho, NAA/Cr + PCr, and Cho/Cr + PCr at TE = 272 msec were calculated. The experiments were carried out using a Siemens Helicon SP 63/84 wholebody MR-scanner at 1.5 T. In the younger age group, the concentration of NAA was significantly higher in the occipital part than in the other three parts of the brain. No significant regional variation was found for any other metabolite concentration. There was a significantly higher concentration of NAA in the occipital part of the brain in the younger age group compared to the older one. No significant regional or age dependent variation was found concerning the T1 and T2 relaxation times.

Adult↗

In vivo quantification of brain metabolites by 1H-MRS using water as an internal standard.

The reliability of absolute quantification of average metabolite concentrations in the human brain in vivo by 1H-MRS using the fully relaxed water signal as an internal standard was tested in a number of in vitro as well as in vivo measurements. The experiments were carried out on a SIEMENS HELICON SP 63/84 wholebody MR-scanner operating at 1.5 T using a STEAM sequence. In vitro studies indicate a very high correlation between metabolite signals (area under peaks) and concentration, R = 0.99 as well as between metabolite signals and the volume of the selected voxel, R = 1.00. The error in quantification of N-acetyl aspartate (NAA) concentration was about 1-2 mM (6-12%). Also in vivo a good linearity between water signal and selected voxel size was seen. The same was true for the studied metabolites, N-acetyl aspartate (NAA), creatine/phosphocreatine (Cr/PCr), and choline (Cho). Calculated average concentrations of NAA, Cr/PCr, and Cho in the occipital lobe of the brain in five healthy volunteers were (mean +/- 1 SD) 11.6 +/- 1.3 mM, 7.6 +/- 1.4 mM, and 1.7 +/- 0.5 mM. The results indicate that the method presented offers reasonable estimation of metabolite concentrations in the brain in vivo and therefore is useful in clinical research.

Body Water↗

Increased water self-diffusion in chronic plaques and in apparently normal white matter in patients with multiple sclerosis.

A new method for measurement of water self-diffusion compensating for zeroth and first order movements was used to study the apparent diffusion coefficient (ADC) in 15 patients with chronic multiple sclerosis (MS) and in two patients with acute MS. Ten healthy volunteers served as controls. A significantly higher ADC was found within chronic plaques compared to the apparently normal white matter of the chronic patients. The ADC was higher in the acute plaques compared to the chronic plaques. The ADC in apparently normal white matter of the chronic patients were significantly higher than in white matter of healthy volunteers. We hypothesize that an increase of the ADC in plaques may be related to an increase in the extracellular space due to oedema and demyelination. The increased ADC in apparently normal white matter suggests that there may be a change in the composition of the white matter of chronic MS patients, perhaps related to oedema and expanded extracellular space.

Adult↗

Functional MR imaging at 1.5 T. Initial results using photic and motoric stimulation.

A preliminary investigation of the effects of stimulation of the visual and the motor cortex was made on a conventional 1.5 T MR imaging scanner. Both types of activation gave a detectable change in the signal between rest and stimulation using a gradient echo sequence with an echo time of 60 ms. The observed effects were assumed to be caused by variation in the amount of paramagnetic deoxyhemoglobin between stimulation and rest due to local increase of capillary blood flow in the human brain during stimulation.

Brain↗

Simultaneous electromyography and 31P nuclear magnetic resonance spectroscopy--with application to muscle fatigue.

The electromyogram (EMG) is often used to study human muscle fatigue, but the changes in the electromyographic signals during muscle contraction are not well understood in relation to muscle metabolism. The 31P NMR spectroscopy is a semi-quantitative non-invasive method for studying the metabolic changes in human muscle. The aim of this study was to develop a method by which EMG and NMR spectroscopy measurements could be performed simultaneously. All measurements were performed in a whole body 1.5 Tesla NMR scanner. A calf muscle ergometer, designed for use in a whole body NMR scanner, was used. The subject had the left foot strapped to the ergometer. The anterior tibial EMG was recorded by bipolar surface electrodes. A surface coil was strapped to the anterior tibial muscle next to the EMG electrodes. Simultaneous measurements of surface EMG and surface coil 31P NMR spectroscopy were performed in the scanner during an isometric submaximal voluntary contraction until exhaustion, in 6 normal volunteers. Concentrations of phosphocreatine (PCr), inorganic phosphate (P(i)) and pH were analysed together with root mean square (RMS) and median frequency of the EMG. The fatiguing contractions (endured 5-13 min) produced a rapid decline in PCr and pH accompanied by a rapid rise in P(i). The RMS was approximately constant until the normalized PCr concentration declined below 0.6-0.7 and the pH declined below 6.75-6.85; exceeding these metabolic limits was associated with a rapidly increasing RMS value (2-3 times the previous level by exhaustion). The median frequency declined linearly with time and was found to be highly linearly correlated with the pH value (r = 0.82).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

In vivo magnetic resonance diffusion measurement in the brain of patients with multiple sclerosis.

Measurement of water self-diffusion in the brain in 25 patients with multiple sclerosis was performed by magnetic resonance imaging. Quantitative diffusion measurements were obtained using single spin-echo pulse sequences with pulsed magnetic field gradients of different magnitude. Twenty-two of these patients also underwent measurement of the transverse relaxation time (T2). Only one plaque was evaluated in each patient. Based on prior knowledge, 12 plaques were classified as being 3 mo or less in age, and 7 plaques were classified as being more than 3 mo old. In all 25 plaques, water self-diffusion was found to be higher than in apparently normal white matter. Furthermore, water self-diffusion was found to be higher in acute plaques compared with chronic plaques. Finally, a slight tendency toward a relationship between the diffusion capability and T2 was found. We believe that an increased diffusion capability signifies an increase of the extracellular water space, which probably is related to the degree of demyelination. Thus, measurement of water self-diffusion in multiple sclerosis plaques may contribute to the study of pathogenesis of demyelination.

Adult↗

Assessment of left ventricular volumes by magnetic resonance in comparison with radionuclide angiography, contrast angiography and echocardiography.

The present study shows that for assessment of LVEF, MRI and the standard methods seem to provide information of similar value. For absolute volume measurements, MRI and RNA are superior to single plane angiography and 2 DE using the modified Simpson-rule. The time consuming transversal MRI method does not seem to be superior to the oblique multislice method, when apical aneurysms can be ruled out. MRI thus seems to be an accurate method for determination of LV stroke volume as well as for determination of LVEF and hence for diastolic and systolic volumes. MRI, however, depends of a good image quality, which is crucial especially in dilated ventricles containing stagnant or slowly moving blood.

Adult↗

Esophageal scintigraphy: reproducibility and normal ranges.

Esophageal scintigraphy has been rather widely used, but much debated as a simple screening method of esophageal dysfunction. However, reports of normal ranges, age dependence and reproducibility are very limited. We studied 60 healthy subjects with a mean age of 43 yr (26, 19, 15 subjects aged 20-39, 40-59, and 60-79 yr) to establish normal ranges and variations of esophageal mean transit time and residual activity measured by a radionuclide method using [99mTc] pertechnetate labeled water. Mean transit time was calculated by Zierler's formula. The median values and 95% percentiles of single measurements of MTT and residual activity in the supine position were 6.1 (3.2-11.5) sec and 11.5 (3.0-50)%, respectively. The coefficients of variation (CV) were 20%-35% for mean transit time and 85%-120% for residual activity in the sitting and supine positions. When double measurements were used, the CVs were reduced to 10% for MTT and 40% for residual activity in the supine position. The values did not change with age except for a higher frequency of spikes in subjects over 40 yr. The study has demonstrated that mean transit time for radiolabeled water in the esophagus of healthy subjects, measured by double determinations, has rather low, age-independent, interobserver and intersubject variabilities. In contrast, measurements of residual activity shows unacceptably high variations.

Adult↗

Quantitation of blood-brain barrier defect by magnetic resonance imaging and gadolinium-DTPA in patients with multiple sclerosis and brain tumors.

In this study quantitation of the degree of deficiency of the blood-brain barrier (BBB) in patients with multiple sclerosis or brain tumors, by using MRI, is shown to be possible. As a measure of permeability of the BBB to Gadolinium-DTPA (Gd-DTPA) the flux per unit of distribution volume per unit of brain mass was used. This quantity was found by introducing the longitudinal relaxation rate (R1) as a measure of concentration of Gd-DTPA in the brain tissue in the mathematical model for the transcapillary transport over the BBB. High accordance between the observed data points and the model was found, and the results were comparable to results obtained from similar studies using positron emission tomography. The improved possibility of quantitating the defect of the BBB by MRI may give new information about pathogenesis or etiology, and leads to improved methods in monitoring the efficacy of treatments in intracranial diseases.

Blood-Brain Barrier↗

Combined left and right ventricular volume determination by radionuclide angiocardiography using double bolus and equilibrium technique.

Eighteen patients with ischaemic heart disease were studied. Left and right ventricular volumes including cardiac output (forward flow) were determined by radionuclide angiocardiography using a double bolus and equilibrium technique. As reference, cardiac output was simultaneously measured by indicator dilution. The radionuclide technique comprised four steps: (1) a first-pass study of right ventricle; (2) a bolus study of left ventricle; (3) an equilibrium study of left ventricle; (4) determination of the distribution volume of red blood cells. Absolute volumes of left ventricle were determined from steps 2 + 3 + 4. Absolute volumes of right ventricle were calculated from stroke volume and right ventricular ejection fraction (EF) which in turn was determined from step 1 by creating composite systolic and composite diastolic images. There was an acceptable agreement between stroke volume determinations by radionuclide angiocardiography and indicator dilution (r = 0.74; P less than 0.001). Stroke volume determination by radionuclide was 83 +/- 20 ml (mean +/- SD) and by indicator dilution 84 +/- 20 ml with a difference of -1 +/- 15 ml (NS). Cardiac output determination by radionuclide was 5.24 +/- 1.37 l min-1 and by indicator dilution 5.28 +/- 1.23 l min-1 with a difference of -0.04 +/- 0.95 l min-1 (NS). Left ventricular EF was 0.44 +/- 0.14 and right ventricular EF 0.57 +/- 0.10. The intra-observer coefficient of variation for duplicate calculations of the radionuclide determinations was 5.5% for stroke volume, 2.5% for left ventricular EF and 4.8% for right ventricular EF.

Blood Volume↗

Fourier analysis of cerebrospinal fluid flow velocities: MR imaging study. The Scandinavian Flow Group.

An interleaved pseudocinematographic FLASH (fast low-angle shot) sequence with additional pulsed gradients for flow encoding was used to quantify cerebrospinal fluid (CSF) flow velocities and CSF production. Flow-dependent phase information was obtained by subtracting two differently encoded phase images. The phase information in the resultant image was converted to flow velocity with a calibration curve with the slope 26.5 radian.m-1.sec. The velocity versus time function was Fourier transformed and a continuous curve was fitted to the measured data with use of the first three harmonics. The in vivo measurements showed a significant variation in flow velocities in the cerebral aqueduct (range, 6-51 mm/sec). Calculated CSF production was in the range of 0.6-1.2 L/24 h. The present method gives valuable information about CSF hydrodynamics in an imaging time of less than 8 minutes.

Adult↗

Evaluation of right ventricular volumes measured by magnetic resonance imaging.

Right ventricular volumes were determined in 12 patients with different levels of right and left ventricular function by magnetic resonance imaging (MRI) using an ECG gated multisection technique in planes perpendicular to the diastolic position of the interventricular septum. Right ventricular stroke volume was calculated as the difference between end-diastolic and end-systolic volume and compared to left ventricular stroke volume and to stroke volume determined simultaneously by a classical indicator dilution technique. There was good agreement between right ventricular stroke volume determined by MRI and by the indicator dilution method and between right and left ventricular stroke volume determined by MRI. Thus, MRI gives reliable values not only for left ventricular volumes, but also for right ventricular volumes. By MRI it is possible to obtain volumes from both ventricles simultaneously in a noninvasive way and without exposing the patient to radiation.

Adult↗

Prognosis and thallium-201 scintigraphy in patients admitted with chest pain without confirmed acute myocardial infarction.

Exercise and rest thallium scintigraphy and exercise electrocardiography were performed after discharge in 158 patients aged less than 76 years admitted with chest pain in whom a suspected diagnosis of acute myocardial infarction had not been confirmed. During a follow up of 12-24 months (median 14 months) there were 10 cardiac events--that is, non-fatal acute myocardial infarction or cardiac deaths. Transient thallium defects and abnormal ST response (that is ST segment deviation or uninterpretable ST segment) during exercise were correlated significantly with an unfavourable prognosis. One hundred and four patients with neither of these characteristics were at lower risk of a cardiac event than the 19 patients with both of these characteristics. The percentages of patients in these two groups without a cardiac event after one year were 98.1 and 78.8 respectively. Thallium scintigraphy, alone or in combination with exercise electrocardiography, can be used to identify groups at high and low risk of future cardiac events, in patients with chest pain in whom acute myocardial infarction is suspected but not found.

Chest Pain↗

Integration of DSM-III and ICD-8 to be used in a consultation-liaison psychiatric service. Preliminary experiences.

In 1983 a total of 405 patients received psychiatric supervision in somatic departments in the general hospital. At this supervision, these patients were registered by means of a five-axial diagnostic coding according to the DMS III principle, and this was combined with a quantitative global assessment of the severity of the condition. Reliability testing was undertaken by five supervising physicians with a total of 15 patients. The total number of supervisions constituted one supervision per somatic bed per annum. Women were overrepresented, and medical departments made the greatest use of psychiatric supervision. Reactive conditions dominated parallel with a high relative incidence of alcohol-related conditions. In patients with diagnoses of psychoses, only slight to moderate psychiatric symptoms were encountered. This held true also for personality deviations. 50% of the patients had experienced significant psychosocial stress, but 10% of these were diagnosed as having non-reactive psychoses, 52% of the patients had moderate to pronounced disturbances of social function. Half of the patients supervised in this manner could be investigated or treated in the referring departments. Approximately half of the patients in whom referral to private psychiatric specialists was made did not keep these appointments. Reliability testing in the material shows the employability of the diagnostic armamentarium. All in all, the investigation suggests that extension of the liaison psychiatric service in somatic departments would result in a relative increase in the number of patients who could be treated in the referring department and an increase in the number of psychiatric conditions diagnosed. Establishment of a psychiatric outpatient clinic in the somatic environment appears to be indicated.

Alcoholism↗

Evaluation of left ventricular volumes measured by magnetic resonance imaging.

Left ventricular end-diastolic and end-systolic volumes were determined in 17 patients with different levels of left ventricular function by magnetic resonance imaging (MRI). A 1.5 Tesla Magnet was used obtaining ECG triggered single and multiple slices. Calculated cardiac outputs were compared with those measured simultaneously by a classical physiological indicator dilution technique. There was good agreement between cardiac output as measured by MRI and the indicator dilution method, when the multislice technique was used (r = 0.87, p less than 0.001). A poor correlation between the two methods was seen when the single slice technique was used (r = 0.06, p greater than 0.80). The results indicate that MRI is a reliable method for left ventricular volume determination when the multislice technique is used.

Adult↗