PubMed Health⌕ Search

Biomedical subjects

M Sugimachi

Publications and source records attributed to M Sugimachi.

At least 37 records · Page 2Linked to original sources

Chronic adriamycin treatment impairs myocardial interstitial neuronal release of norepinephrine and epinephrine.

Although chronic adriamycin (doxorubicin) treatment is known to induce cardiomyopathic heart failure with sympathetic neurohumoral activation in a dose-dependent manner, its effect on local neuronal catecholamine release at the cardiac sympathetic nerve terminals remains to be clearly determined. Using a cardiac microdialysis technique, we measured dialysate norepinephrine (NE) and epinephrine (Epi) concentrations as indices of myocardial interstitial NE and Epi levels. respectively, in rabbits with chronic adriamycin treatment (ADR) (4 mg/kg/week, 6 weeks, n = 8) and in control rabbits (CNT) (n = 6). Exocytotic release was evoked by the local administration of KCl (100 mM) through the dialysis probe. Basal levels of NE and Epi did not differ between the ADR and CNT groups (NE, 11.6 +/- 6.6 vs. 20.4 +/- 17.2 pg/ml; Epi, 4.0 +/- 0.1 vs. 4.6 +/- 1.7 pg/ml: mean +/- SD). The exocytotic release was suppressed in the ADR compared with the CNT group (NE, 191.4 +/- 144.7 vs. 760.5 +/- 337.8 pg/ml; p < 0.05: Epi, 4.2 +/- 0.4 vs. 20.8 +/- 9.9 pg/ml; p < 0.05). We conclude that chronic adriamycin treatment impairs the neuronal exocytotic release of catecholamine at the cardiac sympathetic nerve terminals.

Animals↗

A novel servo-control system that imposes desired aortic input impedance on in situ rat heart.

To clarify the pathophysiological role of dynamic arterial properties in cardiovascular diseases, we attempted to develop a new control system that imposes desired aortic impedance on in situ rat left ventricle. In 38 anesthetized open-chest rats, ascending aortic pressure and flow waveforms were continuously sampled (1,000 Hz). Desired flow waveforms were calculated from measured aortic pressure waveforms and target impedance. To minimize the difference between measured and desired aortic flow waveforms, the computer generated commands to the servo-pump, connected to a side branch of the aorta. By iterating the process, we could successfully control aortic impedance in such a way as to manipulate compliance and characteristic impedance between 60 and 160% of their respective native values. The error between desired and measured aortic flow waveforms was 70 +/- 34 microl/s (root mean square; 4.4 +/- 1.4% of peak flow), indicating reasonable accuracy in controlling aortic impedance. This system enables us to examine the importance of dynamic arterial properties independently of other hemodynamic and neurohumoral factors in physiological and clinical settings.

Algorithms↗

Counteraction of aortic baroreflex to carotid sinus baroreflex in a neck suction model.

Although neck suction has been widely used in the evaluation of carotid sinus baroreflex function in humans, counteraction of the aortic baroreflex tends to complicate any interpretation of observed arterial pressure (AP) response. To determine whether a simple linear model can account for the AP response during neck suction, we developed an animal model of the neck suction procedure in which changes in carotid distension pressure during neck suction were directly imposed on the isolated carotid sinus. In six anesthetized rabbits, a 50-mmHg pressure perturbation on the carotid sinus decreased AP by -27.4+/-4.8 mmHg when the aortic baroreflex was disabled. Enabling the aortic baroreflex significantly attenuated the AP response (-21.5+/-3.8 mmHg, P<0.01). The observed closed-loop gain during simulated neck suction was well predicted by the open-loop gains of the carotid sinus and aortic baroreflexes using the linear model (-0.43+/-0.13 predicted vs. -0.41 +/-0.10 measured). We conclude that the linear model can be used as the first approximation to interpret AP response during neck suction.

Animals↗

Closed-loop identification of carotid sinus baroreflex transfer characteristics using electrical stimulation.

Although random aortic pressure (AOP) perturbation according to a binary white noise sequence enables us to estimate open-loop dynamic characteristics of the carotid sinus baroreflex under closed-loop conditions, the necessity of arterial catheter implantation limits the applicability of this method in freely moving animal experiments. Thus, we explored a closed-loop system identification method using electrical stimulation. In 6 anesthetized and vagotomized rabbits, we stimulated the aortic depressor nerve with a binary white noise sequence (0-10 Hz) under baroreflex closed-loop conditions while measuring cardiac sympathetic nerve activity (SNA) and AOP. We used a closed-loop identification method to estimate the peripheral arc transfer function from SNA to AOP. The peripheral arc transfer function approximated a second-order low-pass filter and its fitted parameters did not differ from those obtained by an open-loop identification method (dynamic gain: 1.16+/-0.32 vs. 1.02+/-0.11; natural frequency: 0.08+/-0.03 vs. 0.09+/-0.03 Hz; damping ratio: 1.53+/-0.15 vs. 1.57+/-0.21). In 6 different rabbits, we applied intermittent rapid pacing (396 beats/min) under baroreflex closed-loop conditions to estimate the neural arc transfer function from AOP to SNA. The neural arc transfer function approximated a first-order high-pass filter and its fitted parameters did not differ from those obtained by an open-loop identification method (dynamic gain: -1.15+/-0.45 vs. -1.06+/-0.05; corner frequency: 0.12+/-0.05 vs. 0.13+/-0.03 Hz). In conclusion, the closed-loop identification method using electrical stimulation is effective to estimate the neural and peripheral arc transfer functions.

Animals↗

Closed-loop estimation of the open-loop carotid sinus baroreflex transfer function for the use of animal experiments in space.

In order to develop effective counter measures to cardiovascular maladaptation associated with space flight, it is essential to know how dynamic characteristics of blood pressure regulation are altered in space. The open-loop transfer characteristics of the carotid sinus baroreflex can be divided into the neural arc and peripheral arc transfer functions (Ikeda et al. 1996). The neural arc transfer function represents the dynamic input-output characteristics from arterial pressure (AP) to efferent sympathetic nerve activity (SNA), while the peripheral arc transfer function represents those from SNA to AP. Although AP perturbation according to a white noise sequence can be used to estimate the transfer functions under baroreflex closed-loop conditions (Kwanda et al. 1997), arterial catheter implantation necessary to perturb AP limits the applicability of this method to freely moving animal experiments. To overcome this problem, we explored the closed-loop system identification method using electrical stimulation. We used aortic depressor nerve (ADN) stimulation and rapid pacing (RP) of the heart to perturb the arterial baroreflex system.

Algorithms↗

Novel therapeutic strategy against central baroreflex failure: a bionic baroreflex system.

BACKGROUND: Central baroreflex failure in Shy-Drager syndrome and traumatic spinal cord injuries results in severe orthostatic hypotension and often confines the patient to the bed. We proposed a novel therapeutic strategy against central baroreflex failure: implementation of an artificial feedback control system able automatically to regulate sympathetic vasomotor tone, that is, a bionic baroreflex system (BBS). With the use of a rat model of central baroreflex failure, we developed the BBS and tested its efficacy. METHODS AND RESULTS: Our prototype BBS for the rat consisted of a pressure sensor placed into the aortic arch, stimulation electrodes implanted into the greater splanchnic nerve, and a computer-driven neural stimulator. By a white noise approach for system identification, we first estimated the dynamic properties underlying the normal baroreflex control of systemic arterial pressure (SAP) and then determined how the BBS computer should operate in real time as the artificial vasomotor center to mimic the dynamic properties of the native baroreflex. The open-loop transfer function of the artificial vasomotor center was identified as a high-pass filter with a corner frequency of 0.1 Hz. We evaluated the performance of the BBS in response to rapid-progressive hypotension secondary to sudden sympathetic withdrawal evoked by the local imposition of a pressure step on carotid sinus baroreceptors in 16 anesthetized rats. Without the BBS, SAP rapidly fell by 49+/-8 mm Hg in 10 seconds. With the BBS placed on-line with real-time execution, the SAP fall was suppressed by 22+/-6 mm Hg at the nadir and by 16+/-5 mm Hg at the plateau. These effects were statistically indistinguishable from those of the native baroreflex system. CONCLUSIONS: These results suggest the feasibility of a BBS approach for central baroreflex failure.

Animals↗

Development of a servo-controller of heart rate using a cycle ergometer.

In exercise training, precise control of exercise intensity would maximize the training efficacy while minimizing risks. To adjust work rate, heart rate (HR) has been used as a measure of exercise intensity. Thus, we developed a servo-controller of HR using a cycle ergometer. After estimating the transfer function from work rate to HR, we optimized feedback parameters for achieving a quick and stable HR response by means of a computer simulation. We then examined the performance of the servo-controller of HR in 55 healthy volunteers. We set the target HR at 60% and 75% of the age-predicted maximum HR. Times required for HR to reach 90% of the target HR were 136 +/- 33 and 137 +/-22s in the respective protocols. Standard deviations of the steady-state difference between the target and measured HRs were 2.5 +/- 0.6 and 3.8 +/- 1.1 beats/min. We conclude that the developed servo-controller makes it possible to precisely regulate HR and, thereby, exercise intensity.

Adult↗

Exercise-induced QRS prolongation in patients with mild coronary artery disease: computer analysis of the digitized multilead ECGs.

Although exercise-induced QRS prolongation has been reported as a possible marker for inducible ischemia, subtleness of the prolongation makes it unidentifiable from standard, chart-recorded electrocardiograms (ECGs). To overcome such a limitation, we measured the QRS width using high-resolution ECGs and examined the diagnostic value of the exercise-induced QRS prolongation in patients before and after percutaneous transluminal coronary angioplasty (PTCA). In 16 patients with single- (n = 12) or double-vessel disease (n = 4), treadmill exercise ECG tests were performed before and after PTCA, while continuously recording 8-lead ECGs at 500 Hz. The onset of the QRS complexes was defined by the earliest deflection, and the end was defined as the latest deflection among 8 leads with the use of algebraic sum of the absolute voltage and their time derivatives (dV/dt) from all 8 leads. We compared QRS complexes before and 1 minute after exercise. Before PTCA, exercise prolonged the QRS width in all but 3 patients (unchanged in 2, decreased in 1) (84 +/- 7 to 87 +/- 8 ms, P < .005). After PTCA, it decreased in 4, was unchanged in 5, and increased in 7 (83 +/- 7 to 83 +/- 6 ms, not significant). PTCA shortened postexercise QRS width in all but 3 (unchanged in 2, increased in 1: 83 +/- 6 to 87 +/- 8 ms, P < .001). High-resolution ECGs enabled us to measure subtle QRS prolongation induced by mild ischemia. Because the QRS prolongation and ST-segment changes would reflect different aspects of myocardial ischemia, incorporating this measure into ST segment criteria might significantly improve the diagnostic accuracy for coronary artery disease.

Adult↗

Acute effect of tumor necrosis factor-alpha is minimal on mechanics but significant on energetics in blood-perfused canine left ventricles.

OBJECTIVES: We hypothesized that tumor necrosis factor-alpha (TNF-alpha) acutely alters left ventricular mechanoenergetics in blood-perfused hearts. To test this hypothesis, we examined the relation between left ventricular mechanics and energetics, both before and after infusion of TNF-alpha. DESIGN: Prospective, experimental study. SETTING: Research laboratory. SUBJECTS: Nine isolated, blood-perfused canine hearts. INTERVENTIONS: Recombinant human TNF-alpha (90 microg/min) was infused into the coronary circulation of the isolated hearts for 20 mins. MEASUREMENTS AND MAIN RESULTS: In the isolated, cross-circulated, blood-perfused canine left ventricles, left ventricular contractility was assessed through measurement of end-systolic elastance (Ees). Energetics were examined in terms of the end-systolic pressure-volume area-myocardial oxygen consumption (MVo2) relation. TNF-alpha concentration in coronary venous blood was >1000 ng/mL throughout the experiments. Nevertheless, infusion of TNF-alpha barely affected contractility acutely, i.e., there was a minimal decrease during the infusion (8.1+/-2.8% at 10 mins, p < .01) and a minimal increase after the infusion (11.2+/-2.5% at 10 mins, p< .01). Neither did the TNF-alpha infusion affect the slope of the end-systolic pressure-volume area-MVo2 relation. This finding indicated that the chemomechanical conversion efficiency remained unchanged. However, TNF-alpha infusion significantly increased the oxygen cost of contractility by 40% (1.25+/-0.13 vs. 1.75+/-0.24 mL oxygen.mL/mm Hg/beat, p< .05), indicating that MVo2 for the excitation-contraction coupling increased. CONCLUSIONS: TNF-alpha minimally alters left ventricular mechanics, but significantly changes energetics. The latter effect may result from changes in intracellular calcium handling.

Animals↗

New simple methods for isolating baroreceptor regions of carotid sinus and aortic depressor nerves in rats.

We developed new methods for isolating in situ baroreceptor regions of carotid sinus and aortic depressor nerves in halothane-anesthetized rats. After ligation of the root of the external carotid artery, the internal carotid and pterygopalatine arteries were embolized with two ball bearings of 0.8 mm in diameter. Bilateral carotid sinus pressures were changed between 60 and 180 mmHg in 20-mmHg steps lasting 1 min each. The sigmoidal steady-state relationship between aortic and carotid sinus pressures in 11 rats indicated the maximum gain of the carotid sinus baroreflex to be -2. 99 +/- 0.75 at 120 +/- 5 mmHg. An in situ isolation of the baroreceptor area of the right aortic depressor nerve could be made by ligation of the innominate, common carotid, and subclavian arteries in 9 rats. Pressure imposed on the subclavian baroreceptor was altered between 40 and 180 mmHg in 20-mmHg steps lasting 1 min each. The sigmoidal steady-state relationship between the aortic depressor nerve activity and imposed pressure showed that the baroreceptor gain peaked at 118 +/- 4 mmHg. We established an easy approach to the rat baroreflex and baroreceptor research.

Animals↗

New analytic framework for understanding sympathetic baroreflex control of arterial pressure.

The sympathetic baroreflex is an important feedback system in stabilization of arterial pressure. This system can be decomposed into the controlling element (mechanoneural arc) and the controlled element (neuromechanical arc). We hypothesized that the intersection of the two operational curves representing their respective functions on an equilibrium diagram should define the operating point of the arterial baroreflex. Both carotid sinuses were isolated in 16 halothane-anesthetized rats. The vagi and aortic depressor nerves were cut bilaterally. Carotid sinus pressure (CSP) was sequentially altered in 10-mmHg increments from 80 to 160 mmHg while sympathetic efferent nerve activity (SNA) and systemic arterial pressure (SAP) were recorded simultaneously under various hemorrhagic conditions. The mechanoneural arc was characterized by the response of SNA to CSP and the neuromechanical arc by the response of SAP to SNA. We parametrically analyzed the relationship between input and output for each arc using a four-parameter logistic equation model. In baseline states, the two arcs intersected each other at the point at which the instantaneous gain of each arc attained its maximum. Severe hemorrhage lowered the gain and offset of the neuromechanical arc and moved the operating point, whereas the mechanoneural arc remained unchanged. The operating points measured under the closed-loop conditions were indistinguishable from those estimated from the intersections of the two arc curves on the equilibrium diagram. The average root mean square errors of estimate for arterial pressure and SNA were 2 and 3%, respectively. Such an analytic approach could explain a mechanism for the determination of the operating point of the sympathetic baroreflex system and thus helps us integratively understand its function.

Animals↗

Summation of dynamic transfer characteristics of left and right carotid sinus baroreflexes in rabbits.

Although interactions among parallel negative-feedback baroreflex systems have been extensively investigated with respect to their steady-state responses, the dynamic interactions remain unknown. In anesthetized, vagotomized, and aortic-denervated rabbits, we perturbed isolated intracarotid sinus pressure (CSP) unilaterally or bilaterally around the physiological operating pressure according to binary white noise. The neural arc transfer function from CSP to cardiac sympathetic nerve activity (SNA) and the peripheral arc transfer function from SNA to aortic pressure were estimated. The gain values of the neural arc at 0.01 Hz estimated by the left (L) and right (R) CSP perturbations were 0.94 +/- 0.31 and 0.96 +/- 0.25, respectively. The gain value increased to 2.17 +/- 0.97 during the bilateral identical CSP perturbation and was not significantly different from L + R. The phase values of the neural arc did not differ among protocols. No significant differences were observed in the peripheral arc transfer functions among protocols. We conclude that summation of the dynamic transfer characteristics of the bilateral carotid sinus baroreflexes around the physiological operating pressure approximates simple addition.

Animals↗

Dynamic counterbalance between direct and indirect vagal controls of atrioventricular conduction in cats.

The vagal system regulates the atrioventricular conduction time (TAV) via two opposing mechanisms: a direct effect on the atrioventricular node and an indirect effect through changes in heart period (TAA). To evaluate how dynamic vagal activation affects TAV, we stimulated the vagal nerve with frequency-modulated Gaussian white noise and estimated the transfer function from vagal stimulation to the TAV response under conditions of no pacing and constant pacing in anesthetized cats. The effect of changes in TAA on TAV was estimated by a random-pacing protocol. The transfer function from vagal stimulation to TAV has low-pass filter characteristics. Constant pacing increased the maximum step response in TAV (2.4 +/- 1.2 vs. 6.3 +/- 2.2 ms/Hz, P < 0.01). The time constant did not differ between the vagal effect on TAV and that on TAA (2.9 +/- 1.2 vs. 2.3 +/- 0.5 s). Because changes in TAA reciprocally affected TAV without significant delay, the direct and indirect effects were dynamically counterbalanced and exerted stable TAV transient response during vagal stimulation under normal sinus rhythm.

Acoustic Stimulation↗

Novel method to estimate ventricular contractility using intraventricular pulse wave velocity.

We developed a novel technique for estimating ventricular contractility using intraventricular pulse wave velocity (PWV). In eight isolated, cross-circulated canine hearts, we used a fast servo pump to inject a volume pulse into the base of the left ventricular chamber at late diastole and at late systole. We measured the transit time of the volume pulse wave as it traversed the distance from base to apex and calculated the intraventricular PWV. The intraventricular PWV increased from diastole (2.3 +/- 0.4 m/s) to systole (11.7 +/- 2.4 m/s, P < 0.0001 vs. diastole). The square of the intraventricular PWV at late systole correlated linearly with the left ventricular end-systolic elastance (r = 0.939, P < 0.0001) and with the end-systolic Young's modulus (r = 0.901, P < 0.0001). Moreover, the intraventricular PWV was insensitive to preload. We conclude that the intraventricular PWV at late systole reflects left ventricular end-systolic elastance reasonably well. The fact that estimation of PWV does not require volume measurement or load manipulation makes this technique an attractive means of assessing ventricular contractility.

Animals↗

Simultaneous identification of static and dynamic vagosympathetic interactions in regulating heart rate.

We earlier reported that stimulation of either one of the sympathetic and vagal nerves augments the dynamic heart rate (HR) response to concurrent stimulation of its counterpart. We explained this phenomenon by assuming a sigmoidal static relationship between nerve activity and HR. To confirm this assumption, we stimulated the sympathetic and/or vagal nerve in anesthetized rabbits using large-amplitude Gaussian white noise and determined the static and dynamic characteristics of HR regulation by a neural network analysis. The static characteristics approximated a sigmoidal relationship between the linearly predicted and the measured HRs (response range: 212.4 +/- 46.3 beats/min, minimum HR: 96.0 +/- 28.4 beats/min, midpoint of operation: 196.7 +/- 31.3 beats/min, maximum slope: 1.65 +/- 0.51). The maximum step responses determined from the dynamic characteristics were 7.9 +/- 2.9 and -14.0 +/- 4.9 beats. min-1. Hz-1 for the sympathetic and the vagal system, respectively. Because of these characteristics, changes in sympathetic or vagal tone alone can alter the dynamic HR response to stimulation of the other nerve.

Acoustic Stimulation↗

Neuronal uptake affects dynamic characteristics of heart rate response to sympathetic stimulation.

Recently, studies in our laboratory involving the use of a Gaussian white noise technique demonstrated that the transfer function from sympathetic stimulation frequency to heart rate (HR) response showed dynamic characteristics of a second-order low-pass filter. However, determinants for the characteristics remain to be established. We examined the effect of an increase in mean sympathetic stimulation frequency and that of a blockade of the neuronal uptake mechanism on the transfer function in anesthetized rabbits. We found that increasing mean sympathetic stimulation frequency from 1 to 4 Hz significantly (P < 0.01) decreased the dynamic gain of the transfer function without affecting other parameters, such as the natural frequency, lag time, or damping coefficient. In contrast, the administration of desipramine (0.3 mg/kg iv), a neuronal uptake blocking agent, significantly (P < 0.01) decreased both the dynamic gain and the natural frequency and prolonged the lag time. These results suggest that the removal rate of norepinephrine at the neuroeffector junction, rather than the amount of available norepinephrine, plays an important role in determining the low-pass filter characteristics of the HR response to sympathetic stimulation.

Adrenergic Uptake Inhibitors↗

Development of a servo-controller of heart rate using a treadmill.

Although treadmill exercise involves a more familiar range of motions and is thus more physiological in terms of daily activity than cycle ergometer exercise, difficulties in controlling the exercise intensity have limited its utility. As heart rate (HR) has been used as a measure of exercise intensity, controlling HR should allow for the proper control of exercise intensity during treadmill exercise. Thus, a servo-controller framework was applied to regulate HR during treadmill exercise. After estimating an averaged transfer function from speed command to HR, feedback parameters were optimized via a computer simulation in order to achieve a quick and stable HR response. The performance of the servo-controller of HR was then examined in 10 healthy subjects. Standard deviations of the steady-state difference between the target and measured HRs were 2.7+/-0.9 and 5.0+/-1.4 beats/min in the stepwise and ramp target HR protocols, respectively. The rise time to reach 90% of the target HR was 93+/-20 s in the stepwise protocol. It was concluded that a treadmill implemented with a negative feedback mechanism made it possible to precisely regulate HR and thus exercise intensity.

Adult↗

STAT3 mediates the survival signal in oncogenic ras-transfected intestinal epithelial cells.

The oncogenic ras mutation is a common and critical step in gastrointestinal carcinogenesis. In a previous study, we demonstrated that oncogenic ras activated the EGF-related peptide autocrine loop and that the apoptosis resistance observed in the oncogenic ras-stimulated cell (IEC-ras cell) was dependent on this activated EGF-related peptide autocrine loop. STATs (signal transducers and activators of transcription), first identified as intracellular signal transducers stimulated by cytokines, are known to also be activated by EGF. However, the role of STATs in the survival signal of IEC-ras cells is not clear. In the present study, we demonstrate that STAT3 is constitutively activated in ras-stimulated cells and that STAT3 activation is considerably suppressed by the EGF-specific receptor kinase inhibitor AG 1478. We also show that disruption of the STAT3 pathway by introduction of a dominant-negative STAT3 mutant abolishes the apoptosis resistance against UVC and MMC treatment observed in IEC-ras cells without affecting proliferation. Moreover, the expression of Bcl-2 and Bcl-xL, apoptosis-suppressive proteins, is reduced in dominant-negative STAT3-transfected cells. Thus, STAT3 appears to be an important mediator of the antiapoptotic signal in IEC-ras cells.

Acute-Phase Proteins↗