PubMed Health⌕ Search

Biomedical subjects

M Szymkiw

Publications and source records attributed to M Szymkiw.

2 recordsLinked to original sources

Modification of pattern reversal VERs by ocular accommodation.

The amplitudes and implicit times of the P-1 component of monocular transient pattern VERs elicited by reversing checkerboard targets were measured in 6 conditions: (1) Ocular accommodation (Ao) elicited by minus power ophthalmic lenses; (2) Ao stimulated by minus lenses with the natural pupil of the test eye dilated and replaced by an artificial pupil; (3) accommodative demand and pupil size fixed with retinal image size (Ir) changed by afocal minifying lenses, (4) accommodative demand and Ir fixed but pupil size changed; (5) Ao elicited by minus lenses for three sizes of reversing checkerboards, and (6) Ao elicited by minus lenses for a constant checkerboard size with three check sizes. The observed decrease in VER amplitude with Ao could not be attributed entirely to the effects of pupil size or Ir. The rate at which the amplitude of P-1 decreased with Ao was not affected by checkerboard check size, but was closely correlated with checkerboard field size. The implicit time of P-1 first decreased slightly below baseline values at low and moderate levels of Ao and then tended to increase significantly at higher levels. The increase in implicit time at high levels of Ao could be explained adequately by the effects of pupil size alone on the VER. However, where Ao occurred without pupillary miosis, the increase in implicit time could only be explained by focusing error.

Accommodation, Ocular↗

Effects of aniseikonia, anisometropia, accommodation, retinal illuminance, and pupil size on stereopsis.

The sensitivity of clinical measures of stereoacuity in the detection of interocular differences in retinal images was examined in 50 adults with normal binocularity. Interocular differences in retinal image size (aniseikonia), clarity (anisometropia) and brightness, as well as differences in absolute and relative pupil size (anisocoria) were created in small steps over a large range to determine their effect on threshold levels of stereopsis. Their effect on stereoacuity was measured in both contour (Titmus test) and random dot (Randot test) stereograms. Stereoacuity measured by both types of stereograms decreased in a curvilinear manner for aniseikonic and anisometropic test conditions. Monocular blur caused a more rapid decrease in stereoacuity than induced aniseikonia. Stereoacuity measured by the contour stereogram decreased about 1.8 times faster than that measured by the random dot stereogram during induced aniseikonia and anisometropia. This differential sensitivity suggests that the Titmus test would detect small interocular differences in retinal images more effectively than the Randot test in clinical screening procedures for vision abnormalities. However, both tests can miss clinically significant amounts of aniseikonia and anisometropia, and fail to differentiate the cause of reduced stereopsis. Interocular differences in retinal image brightness and pupil size within a normal physiologic range did not reduce stereopsis to clinically unacceptable levels.

Accommodation, Ocular↗