Cannulation of the proximal aorta during long-term membrane lung perfusion.

Prolonged extracorporeal oxygenator support for acute respiratory failure is a clinical reality. Recent experience with 4 patients has demonstrated an advantage in delivery of saturated blood to the root of the aorta during venoarterial (VA) bypass. We have been able to perfuse the heart and bilateral cerebral hemispheres by advancing the tip of a large perfusion cannula to the aortic root from the common femoral artery. When the catheter did not pass beyond the transverse aortic arch, there was marked asymmetry of oxygenator perfusion, as determined by differential oxygen tension in right and left radial artery blood and by xenon-133 scans following isotope injection into the arterial return line. Long-term VA bypass lasting from 5 to 11 days resulted in long-term survival in 2 patients with post-traumatic gram-negative pneumonitis. The other patients, who had viral pneumonitis and post-transfusion respiratory failure, died after 9 and 11 days of membrane oxygenator support. No embolic lesions or arterial or valvular injuries were discovered at autopsy. This is a safe and useful method of providing oxygenated blood to the aortic root for equal distribution to the rest of the body.

Adult↗

Small intrapulmonary artery lung prototypes: design, construction, and in vitro water testing.

Blind-ended, hollow fibers mounted on a pulmonary artery catheter may allow O2 and CO2 transfer in the vena cava, right ventricle, and pulmonary artery. The effects of fiber length, manifold number, and gas oscillation on mass and momentum transfer with water perfusate using mass spectrometry and mass flow controllers were studied. Manifolds with 112-196 microporous polypropylene fibers were mounted on 8 Fr multiple lumen, commercially available pulmonary artery catheters. Fiber lengths varied from 0.5 to 16 cm and surface areas from 7 to 220 cm2. Prototypes with 2 cm long fibers were constructed with 1-15 manifolds. A two manifold prototype with 8 cm long fibers and a surface area of 378 cm2 was also studied. The transfer failed to scale with manifold number because the steady gas flow was maldistributed to the manifolds. Oscillating gas pressures from 780 to 76 mmHg absolute at a rate of 40 cycles/min increased CO2 transfer up to 15-fold and O2 transfer up to 2.5-fold. Oscillation also corrected the maldistribution. Optimal fiber lengths of 3 and 1 cm for O2 and CO2, respectively, were seen with steady gas flow, and 8 cm for both with oscillatory gas flow.

Artificial Organs↗

Effects of blood phase oscillation on gas transfer in a microporous intravascular lung.

It may be possible to design an intravascular membrane lung with gas transfer properties augmented by the natural flow oscillations in the venous and pulmonary circulation caused by the beating heart and ventilatory movements. The authors used a simple dye visualization technique, the Pierce-Donachy assist pump, and mass spectrometry to investigate these effects on membrane lungs made with tethered, blind-ended, microporous, polypropylene fibers using in vitro tests in water saturated with O2, CO2, and He. Prototypes were constructed on a 7.5 Fr pulmonary artery catheter. The fibers had an outer diameter (OD) of 380 microns and a wall thickness of 50 microns and were mounted on 4.8 mm OD sleeves. Control measurements were taken over a range of steady water flows from 0.4 l/min to 3 l/min. While pumping the same water flow rates with a roller pump, the Pierce-Donachy pump generated pulsatile flow at a rate of 45 beats/min and a systolic duration of 300 msec. This produced a phasic flow with an instantaneous average flow velocity varying from 0 to as high as 46 cm/sec. O2 and CO2 transfer increased by as much as 91% and 59%, respectively. The largest effects were seen at the lower water flow rates.

Artificial Organs↗

Polysulfone coating for hollow fiber artificial lungs operated at hypobaric and hyperbaric pressures.

Carbon dioxide transfer is increased when the gas phase of a hollow fiber membrane lung is operated at hypobaric pressures. Oxygen transfer is augmented by hyperbaric pressures. However, uncoated hollow fibers transmit gas bubbles into the blood when operated at a pressure greater than 800 mmHg and may have increased plasma leakage when operated at hypobaric pressures. Ultrathin polymer coatings may avoid this problem while reducing thrombogenicity. The authors coated microporous polypropylene hollow fibers with 380 microns outer diameter and 50 microns walls using 1, 2, 3, and 4% solutions of polysulfone in tetrahydrofuran by dipping or continuous pull through. These fibers were mounted in small membrane lung prototypes having surface areas of 70 and 187 cm2. In gas-to-gas testing, the longer the exposure time to the solution and the greater the polymer concentration, the less the permeation rate. The 3% solutions blocked bulk gas flow. The coating was 1 micron thick by mass balance calculations. During water-to-gas tests, hypobaric gas pressures of 40 mmHg absolute were tolerated, but CO2 transfer was reduced to 40% of the bare fibers. Hyperbaric gas pressures of 2,100 mmHg absolute tripled O2 transfer without bubble formation.

Artificial Organs↗

Small intrapulmonary artery lung prototypes. Mathematical modeling of gas transfer.

Two diffusion models have been developed to analyze gas transfer data previously measured in an intravascular artificial lung consisting of a central gas supply catheter from which are tethered a large number of blind-ended microporous fibers of equal length. A convective-diffusion model (CD) describes the countercurrent transfer of a binary gas pair when gas is supplied at constant pressure conditions, and a well mixed (WM) cycled pressure model predicts transfer when the gas supply pressure is time cycled between compression and vacuum conditions. Regression of gas to gas and liquid to gas excretion data with the CD model resulted in estimates of the liquid phase mass transfer coefficient kAI. Because these values were intermediate between the kAI expected for flow parallel to a cylinder and for flow normal to a cylinder, gas transfer was influenced by both the tethered region of the fiber that was nearly perpendicular to the axis of the test section and the free end of the fiber that rested along the wall of the test section. With a time cycled gas supply pressure, the enhanced carbon dioxide and oxygen excretion predicted by the WM model was similar to the data, but a loss in transfer efficiency with fiber length was not accounted for by the theory.

Algorithms↗