PubMed HealthSearch

Biomedical subjects

M T Swartz

Publications and source records attributed to M T Swartz.

At least 19 recordsLinked to original sources

Right ventricular infarction during left ventricular assist system support.

Left ventricular assist devices are frequently used to bridge patients to cardiac transplantation. As this experience grows, new and unanticipated complications will occur. This report describes a 50-year-old man with ischemic cardiomyopathy being bridged to cardiac transplantation who suffered an acute right ventricular infarction during the interval of support.

Fatal Outcome

Intermittent antegrade tepid versus cold blood cardioplegia in elective myocardial revascularization.

BACKGROUND: The ideal temperature for blood cardioplegia administration remains controversial. METHODS: Fifty-two patients who required elective myocardial revascularization were prospectively randomized to receive intermittent antegrade tepid (29 degrees C; group T, 25 patients) or cold (4 degrees C; group C, 27 patients) blood cardioplegia. RESULTS: The two cohorts were similar with respect to all preoperative and intraoperative variables. The mean septal temperature was higher in group T (T, 29.6 degrees +/- 1.1 degrees C versus 17.5 degrees +/- 3.0 degrees C; p < 0.0001). After reperfusion, group T exhibited significantly greater lactate and acid release despite similar levels of oxygen extraction (p < 0.05). The creatine kinase-MB isoenzyme release was significantly lower in group T (764 +/- 89 versus 1,120 +/- 141 U x h/L; p < 0.04). Hearts protected with tepid cardioplegia demonstrated significantly increased ejection fraction with volume loading, improvement in left ventricular function at 12 hours, and decreased need for postoperative inotropic support (p < 0.05). The frequency of ventricular defibrillation after cross-clamp removal was lower in this cohort (p < 0.05). There were no hospital deaths, and both groups had similar postoperative courses. CONCLUSIONS: Intermittent antegrade tepid blood cardioplegia is a safe and efficacious method of myocardial protection and demonstrates advantages when compared with cold blood cardioplegia in elective myocardial revascularization.

Aged

Mitral valve replacement: randomized trial of St. Jude and Medtronic Hall prostheses.

BACKGROUND: This study was designed to better define the merits of the bileaflet and tilting-disc valves. METHODS: We prospectively randomized 156 patients (mean age, 59 years) to receive either the St. Jude (n = 80) or the Medtronic Hall (n = 76) mitral valve prosthesis between September 1986 and December 1997. The two groups were not significantly different with respect to preoperative New York Heart Association class, left ventricular ejection fraction, incidence of mitral stenosis or insufficiency, extent of coronary artery disease, completeness of revascularization, or cross-clamp or bypass time. RESULTS: The operative mortality (11.2% versus 13.1%, St. Jude versus Medtronic Hall, respectively) and late mortality (27% versus 22%, St. Jude versus Medtronic Hall, respectively) were not significantly different. Follow-up was complete in all hospital survivors with a mean of 60.7 months (range, 1 to 133 months). The analysis of 10-year actuarial survival and freedom from valve-related events demonstrated no significant differences between the cohorts. Freedom from reoperation was higher in the St. Jude group (p < 0.01). Comparisons of patient functional status and echocardiographic hemodynamic parameters obtained at the time of follow-up demonstrated no significant differences between the two prostheses. CONCLUSIONS: This study suggests that there is no difference between the St. Jude and Medtronic Hall prostheses with respect to late clinical performance or hemodynamic results and therefore does not support the preferential selection of either prosthesis.

Aged

Cardiac assist devices.

During the latter half of the twentieth century, physicians have had the capability to support the circulation with mechanical devices. This article gives an historical overview of those devices. Various devices and their complications are described and evaluated. Patient selection and clinical results also are discussed.

Adult

Management of asymptomatic mild aortic stenosis during coronary artery operations.

BACKGROUND: Management of asymptomatic mild aortic stenosis at the time of coronary artery bypass grafting (CABG) remains controversial. We have retrospectively analyzed a cohort of patients requiring aortic valve replacement (AVR) subsequent to CABG and compared their operative morbidity and mortality with that of a group receiving CABG and AVR simultaneously at the first operation. METHODS: Analysis is drawn from 28 patients who required AVR 8 +/- 4 years subsequent to CABG (group A) and 175 patients receiving AVR along with CABG at the primary operation (group B). Groups were similar with respect to age, sex, risk factors for cardiac disease, extent of coronary artery disease, left ventricular function, New York Heart Association class, aortic valve area, number of grafts, and size of prosthesis inserted. RESULTS: Patients having AVR subsequent to CABG had a significantly prolonged aortic cross-clamp time and global myocardial ischemic time and incurred a twofold increase in operative mortality. The actuarial survival at 10 years was not significantly different between cohorts. In the 28 patients in group A, the aortic valve area during the period between operations decreased 0.05 mm2/y. CONCLUSIONS: The operative mortality and morbidity of a second operation for AVR is high, but there is no significant difference in survival at 10 years. In at least a portion of patients having mild aortic stenosis at the time of CABG there will be progression of the stenosis necessitating reoperation at a later date.

Actuarial Analysis

Effect of triiodothyronine on graft function in a model of heart transplantation.

BACKGROUND: Brain death is associated with neuroendocrine changes that result in impaired metabolism, reduced myocardial energy stores, and deteriorating cardiac function. As a result of these changes, a substantial number of normal human hearts are not considered suitable for transplantation. In the hope of preventing these complications and stabilizing the condition of cardiac donors, we compared the function of transplanted hearts from brain-dead rats that received triiodothyronine (T3) (n = 6) with that of hearts from a group that received a placebo (n = 5). METHODS: This experiment was designed to be both blinded and randomized. Brain death was achieved by bilateral carotid ligation and inflation of an intracranial balloon. Triiodothyronine or placebo was administered in a blinded, randomized fashion. The brain-dead donors were then supported with conventional techniques for 2 hours after which time heterotopic transplantation was performed using hypothermic preservation and a working heart model. Hemodynamics of the transplanted hearts were assessed 48 hours postoperatively. RESULTS: The hearts from donors that had been pretreated with T3 were found to have a significantly higher (p < 0.005) peak left ventricular pressure than the hearts from the placebo-treated group (137 +/- 17 mm Hg versus 115 +/- 15 mm Hg). Left ventricular end-diastolic pressure was significantly lower (p < 0.01) in the T3-treated group (5.2 +/- 2.2 mm Hg) compared with the placebo-treated group (6.9 +/- 0.5 mm Hg). There was also a significantly higher (p = 0.03) maximal first derivative of left ventricular pressure in the T3-treated group compared with the placebo-treated group (4,876 +/- 1,348 mm Hg/s versus 3,344 +/- 1,016 mm Hg/s). Finally, the cardiac output in the group given T3 was 93 +/- 16 mL/min compared with 61 +/- 22 mL/min in the group given the placebo (p < 0.01). CONCLUSIONS: Hearts from brain-dead rats that had received T3 before transplantation showed improved postoperative function. The experimental design of predonation brain death, cold immersion storage, and transplantation in a working heart model should make these data more relevant clinically than those previously reported.

Abdomen

Changes of intraaortic balloon volume during pumping in a mock circulation system.

The effects of hemodynamic changes on intraaortic balloon (IAB) volumes were studied experimentally using a helium tachometer in a mock circulatory system. The IAB volume decreased with increases in the heart rate and mean aortic pressure, but the degree of reduction in the IAB volume was different among 4 commercially available IAB drivers. Improvements in IAB consoles are needed to compliment the progress made in percutaneous techniques for IAB insertion resulting in smaller balloons.

Arrhythmias, Cardiac

Optimal control algorithm for pneumatic ventricular assist devices: its application to automatic control and monitoring of ventricular assist devices.

We developed a control and monitoring unit for pneumatic ventricular assist devices (VADs), which provides optimal fill and empty control and real-time evaluation of pump performance. The flow signal of the inflow cannula is integrated every beat to yield pump filling volume per pump diastole. The ejection signal is triggered when pump filling reaches a preset level. The instantaneous mean flow of each beat (stroke volume/cycle length) is compared with the previous beat, and the threshold level is readjusted to optimize flow. This feedback loop is repeated every beat, and pump filling is immediately adjusted to yield maximum pump flow. Simultaneously the mean flow of every 10 beats is compared with that of the previous 10 beats; then, the ejection time is readjusted to optimize flow. Initial clinical application of this unit supports its effectiveness and reliability.

Aged

Double-valve replacement with Medtronic-Hall or St. Jude valve.

To define better the performance of the bileaflet St. Jude and the tilting-disc Medtronic-Hall valves, we retrospectively analyzed 122 patients (St. Jude, 80 patients; Medtronic-Hall, 42 patients) who received simultaneous aortic and mitral replacement from May 1984 until June 1994. The two groups were not different with respect to preoperative clinical and hemodynamic parameters and New York Heart Association functional class. The hospital mortality and late mortality were not significantly different. Risk analysis identified advanced age and previous myocardial revascularization as predictors of operative death. Follow-up was complete in 96 of 103 hospital survivors (93%) and was similar in both groups. The actuarial survival, linearized rates of valve-related complications, and actuarial freedom from valve-related complications were similar in both cohorts. The presence of coronary artery disease negatively influenced the actuarial survival after simultaneous aortic and mitral valve replacement. Postoperative New York Heart Association functional class was not significantly different in either group. These data indicate that the Medtronic-Hall and St. Jude prostheses are not significantly different with respect to their clinical performance and valve-related complications for simultaneous double-valve replacement.

Aortic Valve

Risk stratification in patients bridged to cardiac transplantation.

Patient selection is considered one of the most important factors influencing success in bridge to transplant procedures. However, to date it has been difficult to identify predictors of mortality in this population using univariate or multivariate analysis. In 1988, we developed a scoring system using 21 clinical variables that could be calculated rapidly at the bedside while evaluating potential candidates. Points were designated to these variables using a scale of 1 to 3, 1 having the least adverse effect on survival and 3 the most. Patients received a value of 0 for each variable that did not apply. This scoring system was used in a retrospective analysis for 15 bridge to transplant patients. The results showed a significant difference (p < 0.003) between the 8 survivors (mean score, 5.75 +/- 2.19) and the 7 nonsurvivors (mean score, 11.71 +/- 3.45). Since 1989, we have prospectively calculated the scores in an additional 27 patients. Based on the score, all 42 patients were divided into three groups: group I had scores of 1 to 5; group II, 6 to 10; and group III, 11 to 16. The mean score for group I (16 patients) was 3.69 +/- 1.25. All group I patients survived. Group II patients (n = 15) had a mean score of 7.87 +/- 1.36 and a survival rate of 53%. The mean score for group III (n = 11) was 13 +/- 1.73. Thirty-six percent of these patients survived. Comparison of survival and mean scores among the three groups was statistically significant (p < 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

Effect of advancing age on cost and outcome of coronary artery bypass grafting.

The clinical and billing records of 250 patients (173 men and 77 women) undergoing isolated coronary artery bypass grafting between 1987 and mid-1990 were retrospectively reviewed to determine charges and clinical results as related to age. Patients were stratified by age into five groups of 50 consecutive patients each: group 1, less than 50 years of age; group 2, 50 to 59 years; group 3, 60 to 69 years; group 4, 70 to 79 years; and group 5, 80 years or older. The groups were compared in regard to perioperative clinical variables, long-term follow-up, and total charges. Group 5 had significantly more postoperative complications than the other four groups (p < 0.05). In addition, length of postoperative hospitalization was significantly longer in group 5 compared with groups 1, 2, and 3 (p < 0.05), and operative mortality in group 5 (20%) was significantly higher than that in the other four groups. The mean total charges for group 5 were $73,399, which was significantly higher than the totals in the other four groups (p < 0.05). Actuarial 3-year survival for the hospital survivors was 87%, 89%, 78%, 82%, and 60% for groups 1, 2, 3, 4, and 5, respectively (p < 0.001). Postoperative performance as measured by the Karnofsky scale was significantly lower in group 5 than in groups 1 and 2 (p < 0.05). These data support the premise that elderly patients undergoing coronary artery bypass grafting have more complications, longer hospitalizations, and higher operative mortality than younger patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Vascular complications from intraaortic balloons: risk analysis.

PURPOSE: The purpose of this study was to assess the incidence of and predictors for vascular complications in patients who required perioperative intraaortic balloon pump (IABP) support. METHODS: Data from 580 patients collected with a retrospective review were statistically analyzed with 25 perioperative parameters, and significant variables were evaluated with multivariate analysis. These data were also statistically compared with data from a 1983 study from our institution. RESULTS: Vascular complications occurred in 72 patients (12.4%). The three aortic perforations were fatal. Ipsilateral leg ischemia occurred in 69 patients. Of these, ischemia was resolved in 82% of patients by IABP removal (21), thrombectomy (21), vascular repair (13), fasciotomy (2), or without intervention (2). Six patients died with the intraaortic balloon in place. Four patients required amputation for ischemia, but all survived. CONCLUSIONS: Vascular complications were not predictive of operative death (p = 0.26). Risk analyses with 25 perioperative parameters revealed that history of peripheral vascular disease, female sex, history of smoking, and postoperative insertion were independent predictors of vascular complications. However, most risk for vascular complications cannot be explained by these factors because of a low R2 value. Compared with the results of our 1983 study, the incidence of IABP-related complications has not changed, but the severity of complications has decreased significantly, and IABP-induced death has decreased significantly.

Adult

Implantation technique for the Novacor left ventricular assist system.

The Novacor left ventricular assist system (Baxter Healthcare Corp., Novacor Div., Oakland, Calif.) is currently undergoing clinical investigation as a bridge to cardiac transplantation. The original animal and clinical protocols recommended placement of the pump/energy converter within the peritoneal space. During preclinical cadaver fitting trials, we determined that it might be difficult to place this device in the peritoneal cavity of tall, slender patients, patients having a small muscular abdomen, and many women. We were also concerned that peritoneal placement would increase the risk and severity of infection and that abdominal organs might be injured by direct contact with the pump. In studies in cadavers, we therefore developed a technique using preperitoneal placement of the pump/energy converter. This technique has now been used successfully in more than 200 patients. A detailed description of this insertion technique is presented to facilitate its current use for the implantation of temporary devices and to plan for the implantation of permanent systems.

Assisted Circulation

Noncardiac operations in patients supported with mechanical circulatory support devices.

BACKGROUND: Recent advances in technology as well as refinements of patient selection criteria have improved results of ventricular assistance in patients with end-stage heart disease. With a "normal" cardiac output and the resultant improvement in end-organ perfusion, some patients revert to normal or near normal physiology. Seven patients supported with cardiac assist devices who have undergone general surgical, nonassist device related procedures with the assist device in place are presented. STUDY DESIGN: This is a historical review of seven cases. RESULTS: The surgical procedures included three cholecystectomies, one dialysis catheter placement, and one thoracoscopy. Six patients had Thoratec ventricular assist devices (Thoratec Laboratories Corp., Berkeley, CA) and one was supported with a Jarvik (Symbion, Inc., Tempe, AZ) total artificial heart. In one patient, postcholecystectomy bleeding was the only complication that may have been directly attributable to having an assist device in place. Four patients underwent successful transplantation and three patients died, two during support and one after transplantation. CONCLUSIONS: As heart transplant waiting lists become longer and when permanent ventricular assist devices become available, an increasing number of patients on ventricular assistance will have noncardiac related pathology requiring operative intervention. In our experience, patients supported on mechanical assist devices tolerated these procedures well.

Adult

Working heart model of heterotopic heart-lung transplantation in rats.

A technique for a working heart model of heterotopic heart-lung transplantation is described. The donor aorta and left pulmonary artery are anastomosed to the recipient's abdominal aorta in an end-to-side fashion. Arterial blood from the recipient's abdominal aorta enters the donor left heart via the donor left lung and is ejected into the donor ascending aorta by the transplanted left ventricle. With this model, the donor left ventricle performs work comparable to that of the native heart without hypoxia. This model is easily reproducible and can be applied to various studies, including long-term assessments of cardiac remodeling, long-term efficacy of cardiac preservation, and posttransplantation ventricular performance under more physiologic conditions.

Animals

Eight years' experience with bridging to cardiac transplantation.

Although bridging to cardiac transplantation has become a therapeutic option for transplant candidates whose condition deteriorates while they are awaiting a donor heart, short-term efficacy has not been proved and long-term survival has not been reported. We retrospectively reviewed data on 44 patients who had circulatory assist devices placed as a bridge to transplantation between May 1985 and April 1993. The 35 male and nine female patients ranged in age from 12 to 65 years (mean 43.8 years). Thirty-one patients were supported with 32 Thoratec (18 left ventricular, 14 biventricular), 11 Novacor, and two Jarvik J-7-70 devices. The duration of device support was from 4 hours to 440 days (mean 45.5 days). Fifteen patients did not receive a donor organ because of infection (ten patients), renal failure (five patients), bleeding (nine patients), cerebrovascular accident (three patients), ventricular fibrillation (one patient), and right heart failure (one patient), and all died. Two patients were weaned from support and survived without transplantation. Twenty-seven patients underwent transplantation, and 26 survived (96%). Overall survival was 64% (28/44). Duration of survival ranged from 2 to 96 months (mean 35 months). Among the 28 hospital survivors, there were four late deaths (all transplant recipients) at 3, 6, 14, and 68 months. Posttransplantation actuarial survivals at 1, 5, and 8 years are 88%, 83%, and 66%. Twenty-three of the 24 patients presently alive are in New York Heart Association functional class I. These data demonstrate the short- and long-term efficacy of bridging to transplantation with circulatory support devices. The excellent survival and full functional recovery of patients undergoing transplantation ensure that donor organs are not being "wasted" on the sickest patients.

Actuarial Analysis