Enzymatically-generated fluorescent detection in micro-channels with internal magnetic mixing for the development of parallel microfluidic ELISA.

The Enzyme-Linked Immuno-Sorbent Assay, or ELISA, is commonly utilized to quantify small concentrations of specific proteins for a large variety of purposes, ranging from medical diagnosis to environmental analysis and food safety. However, this technique requires large volumes of costly reagents and long incubation periods. The use of microfluidics permits one to specifically address these drawbacks by decreasing both the volume and the distance of diffusion inside the micro-channels. Existing microfluidic systems are limited by the necessary control of extremely low flow rates to provide sufficient time for the molecules to interact with each other by diffusion only. In this paper, we describe a new microfluidic design for the realization of parallel ELISA in stop-flow conditions. Magnetic beads were used both as a solid phase to support the formation of the reactive immune complex and to achieve a magnetic mixing inside the channels. In order to test the detection procedure, the formation of the immune complex was performed off-chip before the reactive beads were injected into the reaction chamber. Anti-streptavidin antibodies were quantified with low picomolar sensitivity (0.1-6.7 pM), a linear range of 2 orders of magnitude and good reproducibility. This work represents the first step toward a new platform for simple, highly effective and parallel microfluidic ELISA.

Alkaline Phosphatase↗

In vitro thrombogenicity investigation of new water-dispersible polyurethane anionomers bearing carboxylate groups.

New segmented polyurethane (PU) anionomers based on hydroxytelechelic polybutadiene were synthesized via an aqueous dispersion process. Incorporation of carboxylic groups was achieved using thioacids of different length. Surface properties were investigated by mean of water absorption analysis and static contact-angle measurements using water, diiodomethane, formamide and ethylene glycol. Blood compatibility of the PUs was evaluated by in vitro adhesion assays using 111In-radiolabeled platelet-rich plasma and [125I]fibrinogen. Morphology of the adhered platelets was examined by scanning electron microscopy (SEM). Results were compared to two biomedical-grade PUs, namely Pellethane and Tecoflex. Insertion of carboxylic groups increased surface hydrophilicity and limited water uptake ( < 8% for an ion content of 5% by weight). Surface energy of all synthesized PUs was between 40 and 45 mJ/m2. Platelet adhesion and fibrinogen adsorption on the PU anionomer surfaces were affected as a function to the increase of graft length; thiopropionic was the most haemocompatible, followed by thiosuccinic and then thioglycolic acid. SEM analyses of all ionic PU samples exhibited low platelet adhesion to surfaces with no morphological modification. In conclusion, increased hydrophily, dynamic mobility and charge repulsion are synergistic key factors for enhanced haemocompatibility.

Absorption↗

Hemocompatibilty of new ionic polyurethanes: influence of carboxylic group insertion modes.

New segmented polyurethane (PU) anionomers based on hydroxytelechelic polybutadiene (HTPB) were synthesized via two environment-friendly chemical routes. The effects of carboxylic content and ion incorporation mode on the surface properties were investigated by mean of water absorption analysis and static contact angle measurements using water, diiodomethane, formamide and ethylene glycol. Blood compatibility of the PUs was evaluated by in vitro adhesion assay using 111In-radiolabeled platelet rich plasma and 125I-fibrinogen. The morphology of platelet adhesion was also observed by scanning electron microscopy (SEM). Results were compared with a biomedical-grade PU, Pellethane. Insertion of the carboxylic groups on the soft segments (S-alpha series), using thioglycolic acid (TGA), increases surface hydrophilicity, limits water uptake (5%, for an ion content of 3.6 wt%), and reduces platelet adhesion and fibrinogen adsorption on the PUs' surfaces. In contrast, the classical insertion onto the hard segment (H-alpha series), using dimethylolpropionate (DMPA) as chain extender, leads to high water uptake (18%, for an ion content of 3.6 wt%) and promotes platelet and fibrinogen adhesion. SEM analyses of the non-ionic PUs exhibited surfaces with adhered platelets which underwent morphological modification. Similarly, the H-alpha ionic PUs show adherent and activated platelets. On the contrary, no platelet morphology changes were observed on the S-alpha ionic surfaces. In conclusion, insertion of carboxyl groups on the soft segments of PUs reduces their thrombogenicity.

Absorption↗

Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model.

Acute and subacute stents thrombosis along with thrombus mediating neointimal proliferation within the stent struts remain major concerns in coronary stenting. Up to date, there is an obvious lack of data on the thrombogenicity of stent materials in physiological conditions. This study was performed to compare the relative thrombogenicity of nitinol versus stainless steel stents. Nitinol stents were laser cut to reproduce the exact geometry of the stainless steel Palmaz stents and tested in an ex vivo AV shunt porcine model under controlled conditions. Nitinol stents presented only small amounts of white and/or red thrombus principally located at the strut intersections while Palmaz stents clearly exhibited more thrombus. As a result, 125I-fibrin(ogen) adsorption and (111)I-platelets adhesion were significantly lower on nitinol than on stainless steel devices (36%, p = 0.03 for fibrin(ogen) and 63%, p = 0.01 for platelet). These results were confirmed by scanning electron observations showing different thrombus morphologies for nitinol and stainless steel. Along with the unique mechanical properties of nitinol, its promising haemocompatibility demonstrated in our study may promote their increasing use for both peripheral and coronary revascularization procedures.

Alloys↗

Safety of plasma-based sterilization: surface modifications of polymeric medical devices induced by Sterrad and Plazlyte processes.

Plasma-based sterilization is a promising alternative to the use of pure ethylene oxide (EO), for low-temperature clinical sterilization of medical instruments and devices. However, few studies have been published that evaluate its safety in terms of possible damage to materials, particularly polymers. The objective of this work was to evaluate polymer surface modifications induced by commercial plasma-based sterilizers, in comparison with pure EO: Samples from 5 polymer-based devices were subjected to 1, 5, and 10 sterilization cycles by Sterrad-100, Plazlyte, and pure EO. Surface analysis was carried out by X-ray photoelectron spectroscopy (XPS), dynamic contact angle measurements (DCA), and scanning electron microscopy (SEM). Surface oxidation and wettability changes were observed on all samples sterilized by plasma-based techniques, the degree of modifications depending on the sterilizer (Sterrad, Plazlyte) and the type of polymer. Drastic changes of surface appearance were also observed by SEM on PVC samples sterilized by Plazlyte and by pure EO. Possible repercussions on safety are discussed.

Adsorption↗

Low-temperature sterilization using gas plasmas: a review of the experiments and an analysis of the inactivation mechanisms.

Utilizing an ionized gas (plasma) to achieve sterilization is an alternative to conventional sterilization means as far as sterilization of heat-sensitive materials and innocuity of sterilizing agents are concerned. The literature on plasma sterilization is reviewed. A major issue of plasma sterilization is the respective roles of UV photons and reactive species such as atomic and radicals. Insight into this matter is obtained by analyzing the survival curves of microorganisms. In contrast to classical sterilization where such plots show a unique straight line, plasma sterilization yields survival diagrams with two or three different linear segments. Three basic mechanisms are involved in the plasma inactivation of microorganisms: (A) direct destruction by UV irradiation of the genetic material of microorganisms; (B) erosion of the microorganisms atom by atom, through intrinsic photodesorption by UV irradiation to form volatile compounds combining atoms intrinsic to the microorganisms; (C) erosion of the microorganisms, atom by atom, through etching to form volatile compounds as a result of slow combustion using oxygen atoms or radicals emanating from the plasma. In some cases, etching is further activated by UV photons, increasing the elimination rate of microorganisms. These mechanisms make plasma sterilization totally different from classical sterilization techniques and suggest its use to inactivate nonconventional infectious agents such as the abnormal prions.

Bacillus subtilis↗

Plasma-based sterilization: effect on surface and bulk properties and hydrolytic stability of reprocessed polyurethane electrophysiology catheters.

Plasma-based sterilization is a promising alternative to ethylene oxide (EO) for reprocessing of electrophysiology catheters. To assess its safety in terms of material damage, modifications of surface and bulk properties as well as hydrolytic stability of sterilized catheters were evaluated. Polyurethane (PU) single-use electrophysiology catheters were subjected to one, five, and ten sterilization cycles by Sterrad-100S and Plazlyte, as well as by pure EO for comparison. Surface analysis techniques (ATR-FTIR, XPS, DCA) showed oxidation limited to the near-surface layer induced by both plasma-based sterilizers, whereas EO induced slight but deeper alkylation. Using bulk analysis techniques (RP-HPLC, SEC), oligomer alteration was observed after all three sterilization techniques, without modification of molecular weights. Hydrolytic stability of catheters was slightly changed by plasma-based sterilization, with a small increase in released oligomers. Finally, although Plazlyte and Sterrad are both plasma-based techniques, they induced different impacts on catheters, such as the degradation of an additive with Sterrad, and a clear difference in coloration with Plazlyte.

Catheterization↗

Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy.

Nickel-titanium (NiTi) alloy derives its biocompatibility and good corrosion resistance from a homogeneous oxide layer mainly composed of TiO(2), with a very low concentration of nickel. In this article, we described the corrosion behavior of NiTi alloys after mechanical polishing, electropolishing, and sterilization processes using cyclic polarization and atomic absorption. As a preparative surface treatment, electropolishing decreased the amount of nickel on the surface and remarkably improved the corrosion behavior of the alloy by increasing the mean breakdown potential value and the reproducibility of the results (0.99 +/- 0.05 V/SCE vs. 0.53 +/- 0. 42). Ethylene oxide and Sterrad(R) sterilization techniques did not modify the corrosion resistance of electropolished NiTi, whereas a steam autoclave and, to a lesser extent, peracetic acid sterilization produced scattered breakdown potential. In comparing the corrosion resistance of common biomaterials, NiTi ranked between 316L stainless steel and Ti6A14V even after sterilization. Electropolished NiTi and 316L stainless-steel alloys released similar amounts of nickel after a few days of immersion in Hank's solution. Measurements by atomic absorption have shown that the amount of released nickel from passive dissolution was below the expected toxic level in the human body. Auger electron spectroscopy analyses indicated surface contamination by Ca and P on NiTi during immersion, but no significant modification in oxide thickness was observed.

Alloys↗

Effects of sterilization processes on NiTi alloy: surface characterization.

Sterilization is required for using any device in contact with the human body. Numerous authors have studied device properties after sterilization and reported on bulk and surface modifications of many materials after processing. These surface modifications may in turn influence device biocompatibility. Still, data are missing on the effect of sterilization procedures on new biomaterials such as nickel-titanium (NiTi). Herein we report on the effect of dry heat, steam autoclaving, ethylene oxide, peracetic acid, and plasma-based sterilization techniques on the surface properties of NiTi. After processing electropolished NiTi disks with these techniques, surface analyses were performed by Auger electron spectroscopy (AES), atomic force microscopy (AFM), and contact angle measurements. AES analyses revealed a higher Ni concentration (6-7 vs. 1%) and a slightly thicker oxide layer on the surface for heat and ethylene oxide processed materials. Studies of surface topography by AFM showed up to a threefold increase of the surface roughness when disks were dry heat sterilized. An increase of the surface energy of up to 100% was calculated for plasma treated surfaces. Our results point out that some surface modifications are induced by sterilization procedures. Further work is required to assess the effect of these modifications on biocompatibility, and to determine the most appropriate methods to sterilize NiTi.

Algorithms↗

In vitro and in vivo biocompatibility of chitosan-xanthan polyionic complex.

A novel hydrogel, CHITOXAN(TM) (CH-X), has potential as a vehicle for controlled drug delivery. The hydrogel is obtained by complexation of two polysaccharides, chitosan and xanthan. In the present work we investigated the biocompatibility of the complex using in vitro and in vivo models. The cytotoxic effects of CH-X microspheres as well as their degradation products at different concentrations were assessed on fibroblasts (fibroblast cell line L-929) using 3-(4,5-dimethylthiazole-2yl)-2,5-triphenyl tetrazolium) (MTT). The test is based on mitochondrial dehydrogenase cell activity as an indicator of cell viability. Interleukin-1beta (IL-1beta) and tumor necrosis factor-alpha (TNF-alpha) cytokines as well as nitric oxide (NO) production by macrophages (macrophage cell line J-774) were examined as indicators of cell activation. In vivo biocompatibility assessment was performed for 1 to 12 weeks. This study was performed using tablets obtained after compression of CH-X particles implanted at the subcutaneous level in male Wistar rats. CH-X biocompatibility and degradation were investigated using histological studies. Light and transmission electron microscopy (TEM) analyses were used to determine the foreign-body reaction and phagocytosis of the implants by macrophages. Fibroblast exposition to CH-X particles and degradation products did not show cytotoxic effects as measured by MTT test. TNF-alpha production was dependent on CH-X particles concentration, whereas IL-1beta production was found to be dose independent. CH-X extract products stimulated TNF-alpha secretion when used at the highest concentration (10 mg/mL), notably after 28 days' degradation time. No effect was observed on IL-1beta production when CH-X extracts were used in comparison to the control. The effects of CH-X particles on NO secretion were similar as on TNF-alpha. Histological studies showed that CH-X tablets broke down into particles which progressively degraded into smaller fragments. A significant fraction of the fragments was ingested by the macrophages after 12 weeks of implantation. Light microscopy studies showed a weak foreign-body reaction as a function of time and the fibrous layer thickness decreased with time of implantation.

Animals↗

Effect of gas composition on spore mortality and etching during low-pressure plasma sterilization.

The aim of this work was to investigate possible mechanisms of sterilization by low-temperature gas plasma: spore destruction by plasma is compared with etching of synthetic polymers. Bacillus subtilis spores were inoculated at the bottom of glass vials and subjected to different plasma gas compositions (O(2), O(2)/Ar, O(2)/H(2), CO(2), and O(2)/CF(4)), all known to etch polymers. O(2)/CF(4) plasma exhibited much higher efficacy than all other gases or gas mixtures tested, with a more than 5 log decrease in 7.5 min, compared with a 2 log decrease with pure oxygen. Examination by scanning electron microscopy showed that spores were significantly etched after 30 min of plasma exposure, but not completely. We speculate about their etch resistance compared with that of synthetic polymers on the basis of their morphology and complex coating structure. In contrast to so-called in-house plasma, sterilization by Sterrad(R) tended to increase the observed spores' size; chemical modification (oxidation), rather than etching, is believed to be the sterilization mechanism of Sterrad(R).

Bacillus subtilis↗

Study of biodegradation behavior of chitosan-xanthan microspheres in simulated physiological media.

Microspheres of a polyelectrolyte complex hydrogel were prepared from chitosan and xanthan after interaction between the two polyionic polymers. Their biodegradation was studied vs. chitosan. Simulated gastric fluid (SGF, pH 1.2) and intestinal fluid (SIF, pH 7.5) both as biodegradation media and phosphate buffered saline (PBS, pH 7.4) as a negative control were used. The degradation studies were performed at 37 degrees C at 240 rpm permanent stirring to mimic the physiologic conditions. High performance liquid chromatography (HPLC) was carried out to quantify the chitosan degradation products using glucosamine (GA) and N-acetyl-D-glucosamine (N-Ac-GA) as references. The peaks area integration method was used to determine the amount of each degradation product as a function of incubation time in the media. The effect of the media on the morphological structure of microspheres was assessed by scanning electron microscopy. From HPLC studies, it appeared that in SGF and SIF the major degradation products were glucosamine (GA) and N-acetyl-D-glucosamine (NAc-GA). In the first 15 days, oligochitosan fractions were released from the complex, whereas N-acetyl-D-glucosamine was detected in the media after this period. The degradation kinetics were assessed by the measurement of the cumulative degradation products, which showed faster degradation of chitosan than the complex in SGF and SIF. SEM micrographs showed an enhancement of microsphere porosity as a function of incubation time in the simulated physiological media. Our results suggest a better control of the degradation kinetics when chitosan is complexed to xanthan.

Acetylglucosamine↗

Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents.

Nickel-titanium (NiTi) offers many advantages for the fabrication of coronary stents: shape memory, superelasticity, and radiopacity. However, many authors highlighted the selective dissolution of Ni from the alloy during the corrosion process that could lead to potential toxicity. The improvement of the NiTi stent's corrosion resistance by different surface treatments (electropolishing, heat treatment, and nitric acid passivation) was reported in a previous article. In the present study a comparative biocompatibility evaluation of such stents was performed through in vitro and in vivo assays. A cell proliferation test was completed to evaluate the cytotoxicity of surface treated NiTi using human fibroblasts. Then a stent implantation was performed in rabbit paramuscular muscle to study the inflammatory response generated by the same implants. Cell proliferation tests generally indicated an in vitro biocompatibility of our samples similar to the control group. An in vivo implantation study demonstrated the gradual overall reduction with time of the fibrocellular capsule thickness surrounding the implants. After a 12-week implantation period, the fibrous capsules surrounding the different implants tended toward the same value of 0.07 mm, which suggested that all surface treatments produced a similar biological response. This low value of the fibrocellular capsule indicated that our NiTi surface treated implants were relatively inert.

Animals↗

Hard, soft tissue and in vitro cell response to porous nickel-titanium: a biocompatibility evaluation.

Porous nickel-titanium (NiTi) alloys have demonstrated bone attachment as well as tissue ingrowth in the past. However, very few studies have compared porous NiTi soft and hard tissue reactions, and in vitro cell response. We therefore have evaluated the general muscle and bone reaction to porous nickel-titanium. The latter material was implanted in rabbit tibias and back muscle, and assessed after three, six and twelve weeks of implantation. Porous NiTi specimens did not cause any adverse effect regardless of both implantation site and post-surgery recovery time. Muscle tissue exhibited thin tightly adherent fibrous capsules with fibers penetrating into implant pores. We observed that attachment strength of the soft tissue to the porous implant seemed to increase with post-implantation time. Bone tissue demonstrated good healing of the osteotomy. There was bone remodeling characterized by osteoclastic and osteoblastic activity in the cortex. This general good in vivo biocompatibility with muscle and bone tissue corresponded very well with the in vitro cell culture results we obtained. Fibroblasts seeded on porous nickel-titanium sheets managed to grow into the pores and all around specimen edges showing an another interesting cytocompatibility behavior. These results indicate good biocompatibility acceptance of porous nickel-titanium and are very promising towards eventual NiTi medical device approbation.

Adipose Tissue↗

Effect of modification of oxide layer on NiTi stent corrosion resistance.

Because of its good radiopacity, superelasticity, and shape memory properties, nickel-titanium (NiTi) is a potential material for fabrication of stents because these properties can facilitate their implantation and precise positioning. However, in vitro studies of NiTi alloys report the dependence of alloy biocompatibility and corrosion behavior on surface conditions. Surface oxidation seems to be very promising for improving the corrosion resistance and biocompatibility of NiTi. In this work, we studied the effect on corrosion resistance and surface characteristics of electropolishing, heat treatment, and nitric acid passivation of NiTi stents. Characterization techniques such as potentiodynamic polarization tests, scanning electron microscopy, Auger electron spectroscopy, and X-ray photoelectron spectroscopy were used to relate corrosion behavior to surface characteristics and surface treatments. Results show that all of these surface treatments improve the corrosion resistance of the alloy. This improvement is attributed to the plastically deformed native oxide layer removal and replacement by a newly grown, more uniform one. The uniformity of the oxide layer, rather than its thickness and composition, seems to be the predominant factor to explain the corrosion resistance improvement.

Alloys↗

Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating.

NiTi shape Memory Alloys (SMA) are potential biomaterial candidates for medical devices such as osteosynthesis staples. However, Ni dissolution induced by uniform or localized corrosion could lead to toxicity. In this work, plasma polymerized tetrafluoroethylene (PPFTE) coating is used to improve the corrosion resistance of NiTi plates and corresponding NiTi stables. The scratch test indicates a good surface adhesion of the film but that it lacks cohesiveness. Potentiodynamic tests in physiological Hank's solution show that PPTFE coating improved the pitting corrosion resistance. The passivation range is increased from 35% to 96% compared to the untreated sample and the pit diameter is decreased from 100 microns to 10 microns. The uniformity of the deposited film is a very important parameter. When the film is damaged, the corrosion seems to increase in comparison to the untreated samples. Otherwise, if the staple is carefully manipulated, the coating follows the large deformations induced by the memory effect of the alloy without cracking, and then, protects efficiently the staple from pitting.

Alloys↗

[Stenosis of the small intestine of ischemic origin in the adult (segmental and transmural lesions)].

Focal ischemia of the small intestine does not always lead to necrosis and perforation, but may induce fibrous stenosis which is evidenced clinically by acute or chronic intestinal occlusion. Among 8 intestinal stenoses 5 were revealed by the presence of an intestinal occlusion whereas the others were manifested by intestinal occlusions complicated by subsequent perforation of the intestinal wall. Annulo-tubular stenoses of ischemic origin are frequently accompanied by inflammatory mesenteric adenopathies due to mucosal ulcerations in the septic environment of the intestinal lumen. Their aspect is reminiscent of Crohn's disease or annular carcinoma. Histological examination of the resected loop frequently reveals the primary oschemic origin of the stenotic lesion, characterized by the presence of macrophages loaded with hemosiderin in the thickened inflamed mucosa. The tissue alterations observed resemble those found in myocardial infarction, but the inflammatory response is more pronounced due to the septic medium. Although such stenoses are relatively rare, they should be distinguished from other lesions provoking a narrowing of the intestinal lumen, since their treatment calls for certain therapeutic precautions. In some cases, angioplastic intervention is required in order to improve perfusion of the vascular bed irrigated by the superior mesenteric artery following resection of the stenotic loop and termino-terminal anastomosis. Furthermore, during any operation requiring revascularization of the mesenteric vessels for intestinal angina, it is important to carry out a very careful examination of the state of the small intestine.

Adult↗