PubMed Health⌕ Search

Biomedical subjects

M Taheri

Publications and source records attributed to M Taheri.

At least 19 recordsLinked to original sources

Development of a high efficiency personal/environmental radon dosimeter using polycarbonate detectors.

Passive radon dosimeters, based on alpha particle etched track detectors, are widely used for the assessment of radon exposure. These methods are often applied in radon dosimetry for long periods of time. In this research work, we have developed a highly efficient method of personal/environmental radon dosimetry that is based upon the detection of alpha particles from radon daughters, (218)Po and (214)Po, using a polycarbonate detector (PC). The radon daughters are collected on the filter surface by passing a fixed flow of air through it and the PC detector, placed at a specified distance from the filter, is simultaneously exposed to alpha particles. After exposure, the latent tracks on the detector are made to appear by means of an electrochemical etching process; these are proportional to the radon dose. The air flow rate and the detector-filter distance are the major factors that can affect the performance of the dosimeter. The results obtained in our experimental investigations have shown that a distance of 1.5 cm between the detector and the filter, an absorber layer of Al with a thickness of 12 microm and an air flow rate of 4 l min(-1) offer the best design parameters for a high efficiency radon dosimeter. Then, the designed dosimeter was calibrated against different values of radon exposures and the obtained sensitivity was found to be 2.1 (tracks cm(-2)) (kBq h m(-3))(-1). The most important advantages of this method are that it is reliable, fast and convenient when used for radon dose assessment. In this paper, the optimized parameters of the dosimeter structure and its calibration procedure are presented and discussed.

Dose-Response Relationship, Radiation↗

Improvement and calibration of a SSNT personal dosemeter and study of importance of albedo factor for dose calculation.

The Neutriran albedo neutron dosemeter has been improved and calibrated for neutron personal dosimetry. The Monte Carlo code MCNP4b was used to calculate the thermal neutrons backscattered from the body (albedo factor). Backscattering from the wall, ceiling and floor in calibration room was considered also via simulation by MCNP4C. A semi automated counting system applying a high-resolution scanner was used for counting of tracks. An 241Am source was used to produce similar alpha particles from 10B (n,alpha)7Li reaction for the optimisation of scanner parameters to distinguish and separate the tracks in SSNTD, which lead to a better distinction between etched alpha tracks and, consequently, a higher linear region of dose characteristic.

Algorithms↗

Simulation of a spray scrubber performance with Eulerian/Lagrangian approach in the aerosol removing process.

In this study, a mathematical model has been developed to simulate the performance of a spray scrubber in an industrial ammonium nitrate plant. The model is based on the Lagrangian approach for the droplets movement and particle source in cell (PSI-CELL) model for calculating the droplet concentration distribution. Consequently, unlike former research, the emphasis is on the droplet dynamic behavior. In the current study, for approaching a realistic model, a droplet size distribution rather than average diameter, and also liquid film formation rather than uniform and constant droplet flow rate has been applied. Also, the Eulerian method has been used for the calculation of the particles removal efficiency and energy balance has been applied on the gas to estimate the droplet size distribution. In the experimental section, the concentration of particles and their size distribution in both inlet and outlet gas of the studied scrubber has been measured for the validation of the predicted particles collection efficiency. In addition, the temperature of the gas at inlet, outlet and in the middle of the tower has been measured for the confirmation of the predicted droplet size distribution in the tower. A good consistency between the model and data has been observed. After the model is validated, it is used to investigate the various variable profiles such as liquid film, total projected surface area of the droplets, velocity profile of the droplets and some of the other parameters in the spray scrubbers.

Aerosols↗

Seroprevalence of Toxoplasma gondii infection in stray and household cats in Tehran.

The prevalence of anti-Toxoplasma gondii specific IgG in stray and household cats in Tehran was determined by Indirect Fluorescent Antibody Test (IFAT) on serum samples from 100 cats (50 stray and 50 households). Overall infection rate was 63%. The infection rate in stray cats (90%) was significantly higher (p<0.001) than that of household cats (36%). Last serum positive dilutions varied from 1: 32 to 1: 512 titres in which the highest percentage (27%) was for 1:256 and the least (4.8%) was at 1:32. The rate of infection between male and female cats of both groups was not significantly different; 90.3% versus 89.5% for male and female in stray cats, respectively. Different sexes of household cats were seropositive at the same rate (36%). A high positive correlation (r(2)=0.97) between age and the rate of infection was observed. The prevalence of Toxoplasma gondii infection in cats in Tehran was high, especially in stray cats which are probably the main source of Toxoplasma infection in this area.

Age Factors↗

Simulation of an orifice scrubber performance based on Eulerian/Lagrangian method.

A mathematical model based on Eulerian/Lagrangian method has been developed to predict particle collection efficiency from a gas stream in an orifice scrubber. This model takes into account Eulerian approach for particle dispersion, Lagrangian approach for droplet movement and particle-source-in-cell (PSI-CELL) model for calculating droplet concentration distribution. In order to compute fluid velocity profiles, the normal k-epsilon turbulent flow model with inclusion of body force due to drag force between fluid and droplets has been used. Experimental data of Taheri et al. [J. Air Pollut. Control Assoc. 23 (11) (1973) 963] have been used to test the results of the mathematical model. The results from the model are in good agreement with the experimental data. After validating the model the effect of operating parameters such as liquid to gas flow rate ratio, gas velocity at orifice opening, and particle diameter were obtained on the collection efficiency.

Air Movements↗

Prediction of pressure drop in an orifice scrubber based on a Lagrangian approach.

A mathematical model has been developed to predict pressure drop in an orifice scrubber. This model is based on a Lagrangian approach for droplet movement and a particle-source-in-cell (PSI-CELL) model for calculating droplet concentration distribution. The k-epsilon turbulent model including body force due to the drag force between fluid and droplets was used to evaluate the fluid velocity distribution. The effect of orifice size on pressure drop and the correlations for mean droplet diameter have been studied. The results from the model have been compared with experimental data. This comparison shows excellent agreement between the calculated results and the experimental data.

Air Pollution↗

Self recognition in the Ig superfamily. Identification of precise subdomains in carcinoembryonic antigen required for intercellular adhesion.

The homophilic binding of extracellular domains of membrane-bound immunoglobulin superfamily (IgSF) molecules is often required for intercellular adhesion and signaling. Carcinoembryonic antigen (CEA), a member of the IgSF, is a widely used tumor marker that functions in vitro as a homotypic intercellular adhesion molecule. CEA has also been shown to contribute to tumorigenicity by inhibiting cellular differentiation, an effect that requires the homophilic binding of its extracellular domains. It was of interest, therefore, to identify small subdomain sequences in CEA that could serve as a focus in the design of peptides that disrupt CEA-mediated intercellular adhesion. Three subdomains in the N-terminal domain of CEA, identified by site-directed deletions and point mutations, were shown to be required for intercellular adhesion. Cyclized peptides representing two of these subdomains, (42)NRQII and (80)QNDTG, were found to be effective in blocking CEA-mediated cellular aggregation when added to CEA-expressing transfectants in suspension. Intermolecular binding involving each of these subdomains is therefore essential for intercellular adhesion and cannot be compensated for by known binding contributions of other regions in the CEA molecule. In further support of this assumption, the binding epitope of an anti-CEA monoclonal antibody (monoclonal antibody A20) known to block CEA-mediated adhesion, was shown to bridge two of the three required subdomains: (42)NRQII and (30)GYSWYK.

Amino Acid Sequence↗

Treatment of severe physiologic gingival pigmentation with free gingival autograft.

Melanin is normally found in the skin of all people, and normal pigmentation of the intraoral tissues is a relatively frequent finding. The highest rate of gingival pigmentation has been observed at the incisors. Until recently, however, very little attention has been paid to the esthetic treatment of severe gingival pigmentation. To answer the cosmetic demand for a pleasing smile, pigmented gingiva was replaced with an unpigmented free gingival autograft in 10 patients. At least two areas in each patient were grafted. In all 10 areas in which the recipient site received full-thickness bed preparation, no evidence of repigmentation was found after 4.5 years. Of the 10 areas that received partial-thickness bed preparation, only one exhibited repigmentation (after 1 year).

Adolescent↗

Theoretical study of liquid droplet dispersion in a venturi scrubber.

The droplet concentration distribution in an atomizing scrubber was calculated based on droplet eddy diffusion by a three-dimensional dispersion model. This model is also capable of predicting the liquid flowing on the wall. The theoretical distribution of droplet concentration agrees well with experimental data given by Viswanathan et al. for droplet concentration distribution in a venturi-type scrubber. The results obtained by the model show a non-uniform distribution of drops over the cross section of the scrubber, as noted by the experimental data. While the maximum of droplet concentration distribution may depend on many operating parameters of the scrubber, the results of this study show that the highest uniformity of drop distribution will be reached when penetration length is approximately equal to one-fourth of the depth of the scrubber. The results of this study can be applied to evaluate the removal efficiency of a venturi scrubber.

Air Movements↗

Human carcinoembryonic antigen, an intercellular adhesion molecule, blocks fusion and differentiation of rat myoblasts.

Human carcinoembryonic antigen (CEA), a widely used tumor marker, is a member of a family of cell surface glycoproteins that are overexpressed in many carcinomas. CEA has been shown to function in vitro as a homotypic intercellular adhesion molecule. This correlation of overproduction of an adhesion molecule with neoplastic transformation provoked a test of the effect of CEA on cell differentiation. Using stable CEA transfectants of the rat L6 myoblast cell line as a model system of differentiation, we show that fusion into myotubes and, in fact, the entire molecular program of differentiation, including creatine phosphokinase upregulation, myogenin upregulation, and beta-actin downregulation are completely abrogated by the ectopic expression of CEA. The blocking of the upregulation of myogenin, a transcriptional regulator responsible for the execution of the entire myogenic differentiation program, indicates that CEA expression intercepts the process at a very early stage. The adhesion function of CEA is essential for this effect since an adhesion-defective N domain deletion mutant of CEA was ineffective in blocking fusion and CEA transfectants treated with adhesion-blocking peptides fused normally. Furthermore, CEA transfectants maintain their high division potential, whereas control transfectants lose division potential with differentiation similarly to the parental cell line. Thus the expression of functional CEA on the surface of cells can block terminal differentiation and maintain proliferative potential.

Actins↗