PubMed Health⌕ Search

Biomedical subjects

M Talmant

Publications and source records attributed to M Talmant.

7 recordsLinked to original sources

Apparent Young's modulus of human radius using inverse finite-element method.

The ability to assess the elastic and failure properties of cortical bone at the radial diaphysis has a clinical importance. A new generation of quantitative ultrasound (QUS) devices and peripheral quantitative computed tomography (p-QCT) has been developed to assess non-invasively bone material and structural properties at the distal radius. This anatomical site is characterized by a thin cortical thickness that complicates traditional mechanical testing methods on specimens. Until now, mechanical properties of cortical bone at distal radius (e.g., elastic modulus, yield stress and strain) remain rarely studied probably due to experimental difficulties. The present study introduces an inverse finite-element method strategy to measure the elastic modulus and yield properties of human cortical specimens of the radial diaphysis. Twenty millimeter-thick portions of diaphysis were cut from 40 human radii (ages 45-90) for biomechanical test. Subsequently the same portion was modeled in order to obtain a specimen-specific three dimensional finite-element model (3D-FEM). Longitudinal elastic constants at the apparent level and stress characterizations were performed by coupling mechanical parameters with isotropic linear-elastic simulations. The results indicated that the mean apparent Young's modulus for radial cortical bone was 16 GPa (SD 1.8) and the yield stress was 153 MPa (SD 33). Breaking load was 12,946 N (SD 3644), cortical thickness 2.9 mm (SD 0.6), structural effective strain at the yield (epsilon(y)=0.0097) and failure (epsilon(u)=0.0154) load were also calculated. The 3D-FEM strategy described here may help to investigate bone mechanical properties when some difficulties arise from machining mechanical sample.

Aged↗

Bone micro-damage assessment using non-linear resonant ultrasound spectroscopy (NRUS) techniques: a feasibility study.

Non-linear resonant ultrasound spectroscopy (NRUS) is a technique exploiting the significant non-linear behavior of damaged materials, related to the presence of damage. This study shows for the first time the feasibility of this technique for damage assessment in bone. Two samples of bovine cortical bone were subjected to a progressive damage experiment. Damage accumulation was progressively induced in the samples by mechanical testing. For independent assessment of damage, X-ray CT imaging was performed at each damage step, but only helped in the detection of the prominent cracks. Synchrotron micro-CT imaging and histology using epifluorescence microscopy were performed in one of the two samples at the last damage step and allowed detection of micro-cracks for this step. As the quantity of damage accumulation increased, NRUS revealed a corresponding increase in the non-linear response. The measured change in non-linear response is much more sensitive than the change in elastic modulus. The results suggest that NRUS could be a potential tool for micro-damage assessment in bone. Further work has to be carried out for a better understanding of the physical nature of damaged bone, and for the ultimate goal of in vivo implementation of the technique where bone access will be a challenging problem.

Algorithms↗

Site-matched assessment of structural and tissue properties of cortical bone using scanning acoustic microscopy and synchrotron radiation muCT.

200 MHz scanning acoustic microscopy (SAM) and synchrotron radiation muCT (SR-muCT) were used to assess microstructural parameters and tissue properties in site-matched regions of interest in cortical bone. Anterior and postero-lateral regions of ten cross sections from human cortical radius were explored. Structural parameters, including diameter and number of Haversian canals per cortical area (Ca.Dm, N.Ca/Ar) and porosity Po were assessed with both methods using a custom-developed image fusion and analysis software. Acoustic impedance Z and degree of mineralization of bone DMB were extracted separately for osteonal and interstitial tissues from the fused images. Structural parameter estimations obtained from radiographic and acoustic images were almost identical. DMB and impedance values were in the range between 0.77 and 1.28 g cm(-3) and 5.13 and 12.1 Mrayl, respectively. Interindividual and regional variations were observed, whereas the strongest difference was found between osteonal and interstitial tissues (Z: 7.2 +/- 1.1 Mrayl versus 9.3 +/- 1.0 Mrayl, DMB: 1.06 +/- 0.07 g cm(-3) versus 1.16 +/- 0.05 g cm(-3), paired t-test, p < 0.05). Weak, but significant correlations between DMB and Z were obtained for the osteonal (R(2) = 0.174, p < 10(-4)) and for the pooled (osteonal and interstitial) data. The regression of the pooled osteonal and interstitial tissue data follows a second-order polynomial (R(2) = 0.39, p < 10(-4)). Both modalities fulfil the requirement for a simultaneous evaluation of cortical bone microstructure and material properties at the tissue level. While SAM inspection is limited to the evaluation of carefully prepared sample surfaces, SR-muCT provides volumetric information on the tissue without substantial preparation requirements. However, SAM provides a quantitative estimate of elastic properties at the tissue level that cannot be captured by SR-muCT.

Aged↗

Comparison of three ultrasonic axial transmission methods for bone assessment.

This study compared three approaches to bone assessment using ultrasonic axial transmission. In 41 fresh human radii, velocity of the first arriving signal was measured with a commercial device (Sunlight Omnisense) operating at 1.25 MHz, a prototype based on 1-MHz bidirectional axial transmission and a low-frequency (200 kHz) prototype, also measuring the velocity of a slower wave. Cortical and trabecular bone mineral density, cortical thickness and cross-sectional area were determined by peripheral quantitative computed tomography. Significant but modest correlation between velocities reflects differences in the nature of the propagating waves and methodological differences. Of the higher frequency devices, bidirectional measurements provided stronger correlations with bone properties than did conventional measurements. High-frequency devices were less sensitive to cortical thickness than was the low-frequency device, because higher frequency waves interrogate thinner cortical layers. The results suggest that different axial transmission approaches reflect different bone properties. Therefore, a multifrequency technique might be useful in probing different bone properties.

Aged↗

Contrast and velocity ultrasonic tomography of long bones.

Our objective is to derive quantitative sound speed images of cortical bone using ultrasonic transmission tomography. Cortical bone is a highly refracting medium, i.e., the sound velocity changes abruptly across the interface between soft tissue and bone. It results in a loss of data compared to classical tomography in soft tissues. In order to correct for degradation by refraction effects, the classical acquisition procedure of projection data is modified: the transducers are oriented according to Snell's law of refraction with the aim of optimizing the sound propagation as parallel longitudinal rays inside the bone. This strategy allows the subsequent application of straight-ray reconstruction by the backprojection technique, which is a classical procedure in x-ray tomography. The method is validated with Plexiglas solid cylinders and tubes immersed in water. Improved sound velocity images are then derived using conventional Radon transform of the experimental time-of-flight data. The method is then extended to in vitro human femur immersed in water. The geometry of the bone cross-section is reconstructed from measurements using ultrasonic reflection tomography. The result is then introduced in the calculation of the position and orientation of the transducers, which are associated with the parallel acoustical paths in bone in the transmission measurements. The procedure leads to significant restoration enhancement over the non corrected image. The mean value of the velocity of 3,200 ms(-1) in the cortical shell is consistent with the values known from literature. These preliminary quantitative images using combined reflected and transmission ultrasound show promise for bone imaging.

Elasticity↗

Analysis of the axial transmission technique for the assessment of skeletal status.

Ultrasonic wave propagation in human cortical bone has been investigated in vitro using the so-called axial transmission technique. This technique, which relies on velocity measurement of the first arriving signal, has been used in earlier investigations to study bone status during fracture healing or osteoporosis. Two quasi-point-source elements, one transmitter and one receiver (central frequency 0.5 MHz), were used to generate a wide ultrasonic beam, part of which strikes the sample surface at the longitudinal critical angle, and to receive the signals reflected from the sample surface. The analysis of the field reflected from a fluid-solid interface for an incident spherical wave predicts the existence of a lateral wave propagating along the sample surface at a velocity close to the longitudinal velocity, in addition to the ordinary reflected wave and vibration modes. The transducer-sample and the transmitter-receiver distances were chosen such that the lateral wave is the first arriving signal. Validation of the measuring technique was performed on test materials and was followed by experiments on human cortical bones. Experimental results (arrival time and velocity) strongly suggest that the first detected signal corresponds to the lateral wave predicted by theory.

Bone Density↗

The wave bivector formalism associated with circumferential leaky waves

It is shown that the circumferential internal waves propagating around an elastic cylinder can be locally seen as plane evanescent waves, at any observation point inside the surrounding fluid. This is done by direct calculation of the associated complex bivector. The exact anatomy of the wave is detailed and the phase propagation paths are found to be curved, as expected. The transition to the plane interface is achieved. Polarization ellipses associated with the acoustic displacement vector are described. The additional low evanescence assumption leads to conventional ray interpretation with identification of the ray tube divergence coefficients, and the wavefront is found to be the involute of a circle.

Journal Article↗