Conservative non-pharmacological treatment options are not frequently used in the management of hip osteoarthritis.

Osteoarthritis (OA) is the most frequent joint disorder in seniors. Systematic reviews suggest that conservative treatment is effective and preferred in mild-moderate cases. The objective of this study was to examine the proportion of patients receiving physiotherapy, exercise or walking aids, and to explore factors associated with their prescription. We conducted a retrospective survey of patients about to undergo total hip arthroplasty for hip osteoarthritis. Patients were asked about past prescriptions for cane use, physiotherapy and exercise. Of 161 patients (36.6% male, mean age 68.7+/-10.1 years), 76% were prescribed a cane (adherence=86.2%). The main reason for not using a cane was vanity. Of the 28.0% patients prescribed physiotherapy, 73.3% received exercises compared to only 2.6% of non-physiotherapy patients. Patients who were older or worked in manual labour were more likely to be prescribed a cane and less likely to be prescribed physiotherapy or exercises. Men were less likely than women to be prescribed all three, but only cane use was statistically significant across genders. In conclusion, physiotherapy and exercise are not commonly prescribed in patients with hip OA.

Aged↗

Role of capsular repair on dislocation in revision total hip arthroplasty.

Dislocation remains one of the most common complications after revision total hip arthroplasty (THA). In contrast to primary THA the posterior capsule has been routinely excised to provide better visualization, but its role in preventing dislocation has been overlooked. We reviewed 69 patients (79 hips) patients who had revision THA with a posterolateral approach to determine if closing the posterior capsule resulted in a fewer dislocations. We followed the patients for a minimum of 24 months (mean 57 months, range, 24-120 months). Two (2.5%) hips dislocated. Both dislocated anteriorly in the immediate postoperative period. One dislocation was from implant malposition and the other occurred in a high risk patient. There were no posterior dislocations and no patients reported any hip subluxation. The historically high dislocation rates with the posterolateral approach can be reduced by carefully balancing soft tissues, ensuring correct implant alignment, meticulously closing the posterior capsule, and reattaching the external rotators.

Adult↗

Zoledronic acid causes enhancement of bone growth into porous implants.

The effect of zoledronic acid on bone ingrowth was examined in an animal model in which porous tantalum implants were placed bilaterally within the ulnae of seven dogs. Zoledronic acid in saline was administered via a single post-operative intravenous injection at a dose of 0.1 mg/kg. The ulnae were harvested six weeks after surgery. Undecalcified transverse histological sections of the implant-bone interfaces were imaged with backscattered scanning electron microscopy and the percentage of available pore space that was filled with new bone was calculated. The mean extent of bone ingrowth was 6.6% for the control implants and 12.2% for the zoledronic acid-treated implants, an absolute difference of 5.6% (95% confidence interval, 1.2 to 10.1) and a relative difference of 85% which was statistically significant. Individual islands of new bone formation within the implant pores were similar in number in both groups but were 69% larger in the zoledronic acid-treated group. The bisphosphonate zoledronic acid should be further investigated for use in accelerating or enhancing the biological fixation of implants to bone.

Animals↗

Acid-etched microtexture for enhancement of bone growth into porous-coated implants.

We designed an in vivo study to determine if the superimposition of a microtexture on the surface of sintered titanium beads affected the extent of bone ingrowth. Cylindrical titanium intramedullary implants were coated with titanium beads to form a porous finish using commercial sintering techniques. A control group of implants was left in the as-sintered condition. The test group was etched in a boiling acidic solution to create an irregular surface over the entire porous coating. Six experimental dogs underwent simultaneous bilateral femoral intramedullary implantation of a control implant and an acid etched implant. At 12 weeks, the implants were harvested in situ and the femora processed for undecalcified, histological examination. Eight transverse serial sections for each implant were analysed by backscattered electron microscopy and the extent of bone ingrowth was quantified by computer-aided image analysis. The extent of bone ingrowth into the control implants was 15.8% while the extent of bone ingrowth into the etched implants was 25.3%, a difference of 60% that was statistically significant. These results are consistent with other research that documents the positive effect of microtextured surfaces on bone formation at an implant surface. The acid etching process developed for this study represents a simple method for enhancing the potential of commonly available porous coatings for biological fixation.

Animals↗

Relative contributions of chemistry and topography to the osseointegration of hydroxyapatite coatings.

The purpose of the current study was to ascertain the relative contributions of surface chemistry and topography to the osseointegration of hydroxyapatite-coated implants. A canine femoral intramedullary implant model was used to compare the osseous response to commercially pure titanium implants that were either polished, grit-blasted, plasma-sprayed with hydroxyapatite, or plasma-sprayed with hydroxyapatite and masked with a very thin layer of titanium using physical vapor deposition (titanium mask). The titanium mask isolated the chemistry of the underlying hydroxyapatite layer without functionally changing its surface topography and morphologic features. At 12 weeks, the bone-implant specimens were prepared for undecalcified thin section histologic evaluation and serial transverse sections were quantified with backscattered scanning electron microscopy for the percentage of bone apposition to the implant surface. Bone apposition averaged 3% for the polished implants and 23% for the grit-blasted implants. Bone apposition to the hydroxyapatite-coated implants averaged 74% whereas bone apposition to the titanium mask implants averaged 59%. Although there was significantly greater osseointegration with the hydroxyapatite-coated implants, 80% of the maximum bone forming response to the implant surfaces developed with the titanium mask implants. This simple, controlled experiment revealed that topography is the dominant factor governing bone apposition to hydroxyapatite-coated implants.

Animals↗

Enhancement of bone growth into porous intramedullary implants using non-invasive low intensity ultrasound.

An in vivo study was designed to determine if non-invasive low intensity ultrasound could enhance bone growth into porous intramedullary implants. Fully porous intramedullary rods were implanted bilaterally into the ulnae of six dogs. In each dog, one ulna served as a control and the other was treated with 20 min of daily ultrasound stimulation for 6 consecutive weeks. Analysis of serial transverse sections indicated an average of 119% more bone growth into the ultrasound-treated implants compared with the contralateral controls (P < 0.001). In each of the 6 dogs, there was a significantly greater amount of bone ingrowth on the ultrasound-stimulated side. These data indicate a clear potential for externally applied ultrasound therapy to augment biological fixation.

Animals↗

Femoral remodeling after porous-coated total hip arthroplasty with and without hydroxyapatite-tricalcium phosphate coating: a prospective randomized trial.

We prospectively assessed femoral bone remodeling using dual-energy x-ray absorptiometry for 2 years after total hip arthroplasty. Thirty-nine hips were randomized to receive a titanium proximally porous-coated femoral component with or without hydroxyapatite-tricalcium phosphate coating. Although both stems resulted in alterations in the periprosthetic bone mineral density, the hydroxyapatite-tricalcium phosphate coated stems had significantly less femoral bone loss than the uncoated stems at 2-year follow-up. This reduced femoral bone loss may provide short-term and long-term advantages over noncoated stems.

Absorptiometry, Photon↗

Primary cementless total hip arthroplasty using a modular femoral component: a minimum 6-year follow-up.

We evaluated 59 hips that underwent a primary total hip arthroplasty using an S-ROM modular femoral component at a mean follow-up of 101 months (range, 72-145 months). All cases showed radiographic evidence of bone ingrowth, and there were no femoral revisions for aseptic loosening. The Harris hip score improved from a mean of 40 preoperatively to 89 at final follow-up. Some degree of proximal femoral disuse atrophy from stress shielding occurred in 46 hips (78%), and some degree of femoral osteolysis occurred in 25 hips (42%). Only additional follow-up will reveal whether there is a consequence of both types of proximal femoral bone loss.

Adolescent↗

Effect of femoral component designs on the contact and tracking characteristics of the unresurfaced patella in total knee arthroplasty.

OBJECTIVES: To determine the effect of 5 different femoral components used in total knee arthroplasty (TKA) on the contact area and tracking characteristics of the nonresurfaced patella and to identify any design features that might adversely affect these characteristics. DESIGN: An in-vitro study. SETTING: The biomechanics laboratory, Department of Mechanical Engineering, McGill University, Montreal. SPECIMENS: Six fresh-frozen cadaveric knee-joint specimens. INTERVENTIONS: An unconstrained quadriceps simulator was used to apply the conditions of static lifting to the specimens first in their normal state and then sequentially implanted with femoral and tibial components of various designs (Miller/Galante II, Anatomic Modular Knee [AMK] System, Whiteside Ortholoc Modular, press-fit condylar and Insall-Burstein II). OUTCOME MEASURES: Patellar 3-dimensional tracking characteristics, determined by using a 6 degrees-of-freedom electromechanical goniometer attached directly to the patella, and patellar contact pressure measurements, obtained using low-range Fuji Prescale film. RESULTS: Articulation of the normal patella on a prosthetic femoral component resulted in alterations in the normal patellofemoral contact and tracking characteristics. The exact departure depended on the design of the prosthetic trochlea. Although all of the selected prostheses demonstrated satisfactory contact characteristics near extension, marked alterations occurred at higher flexion angles. With 90 degrees or more of flexion, there was incompatibility between the geometries of the prosthetic notch of 2 femoral designs (AMK and PFC) and the normal knee. CONCLUSION: The design of the prosthetic femoral component must be taken into account when determining whether or not to resurface the patella at the time of TKA.

Adult↗

Fibrous tissue ingrowth and attachment to porous tantalum.

This study determined the soft tissue attachment strength and extent of ingrowth to a porous tantalum biomaterial. Eight dorsal subcutaneous implants (in two dogs) were evaluated at 4, 8, and 16 weeks. Upon retrieval, all implants were surrounded completely by adherent soft tissue. Implants were harvested with a tissue flap on the cutaneous aspect and peel tested in a servo-hydraulic tensile test machine at a rate of 5 mm/min. Following testing, implants were dehydrated in a solution of basic fuschin, defatted, embedded in methylmethacrylate, and processed for thin-section histology. At 4, 8, and 16 weeks, the attachment strength to porous tantalum was 61, 71, and 89 g/mm respectively. Histologic analysis showed complete tissue ingrowth throughout the porous tantalum implant. Blood vessels were visible at the interface of and within the porous tantalum material. Tissue maturity and vascularity increased with time. The tissue attachment strength to porous tantalum was three- to six-fold greater than was reported in a similar study with porous beads. This study demonstrated that porous tantalum permits rapid ingrowth of vascularized soft tissue, and attains soft tissue attachment strengths greater than with porous beads.

Animals↗

Selective enhancement of collagenase-mediated cleavage of resident type II collagen in cultured osteoarthritic cartilage and arrest with a synthetic inhibitor that spares collagenase 1 (matrix metalloproteinase 1).

OBJECTIVE: To examine whether type II collagen cleavage by collagenase and loss of proteoglycan are excessive in human osteoarthritic (OA) articular cartilage compared with nonarthritic articular cartilage, and whether this can be inhibited by a selective synthetic inhibitor that spares collagenase 1 (matrix metalloproteinase 1 [MMP-1]). METHODS: Articular cartilage samples were obtained during surgery from 11 patients with OA and at autopsy from 5 adults without arthritis. The articular cartilage samples were cultured in serum-free medium. A collagenase-generated neoepitope, which reflects cleavage of type II collagen, and proteoglycan glycosaminoglycan (GAG), which predominantly reflects aggrecan release, were assayed in culture media. In addition, cultures were performed using either of 2 synthetic MMP inhibitors, both of which inhibited collagenase 2 (MMP-8) and collagenase 3 (MMP-13), but one of which spared collagenase 1. Cultures were also biolabeled with 3H-proline in the presence and absence of these inhibitors to measure collagen synthesis (as tritiated hydroxyproline) and incorporation in articular cartilage. RESULTS: As a group, cleavage of type II collagen by collagenase was significantly increased in OA cartilage samples. In contrast, proteoglycan (GAG) release was not increased. This release of a collagenase-generated epitope was inhibited by both MMP inhibitors in 2 of 5 nonarthritic samples and in 9 of 11 OA cartilage samples. The inhibitor that spared collagenase 1 was generally more effective and inhibited release from 4 of 5 nonarthritic cartilage samples and the same OA cartilage samples. Group analyses revealed that the inhibition of collagenase neoepitope release by both inhibitors was significant in the OA patient cartilage, but not in the nonarthritic cartilage. Proteoglycan loss was unaffected by either inhibitor. Newly synthesized collagen (predominantly, type II) exhibited increased incorporation in OA cartilage, but only in the presence of the inhibitor that arrested collagenase 1 activity. CONCLUSION: These results further indicate that the digestion of type II collagen by collagenase is selectively increased in OA cartilage, and that this can be inhibited in the majority of cases by a synthetic inhibitor that can inhibit collagenases 2 and 3, but not collagenase 1. The results also suggest that in OA, newly synthesized collagen is digested, but in a different manner than that of resident molecules. Proteoglycan release was not increased in OA cartilage and was unaffected by these inhibitors. Inhibitors of this kind may be of value in preventing damage to type II collagen in human arthritic articular cartilage.

Adult↗

Potential errors in axial alignment using intramedullary instrumentation for total knee arthroplasty.

Accurate restoration of normal limb alignment is crucial for the long-term survivorship of total knee arthroplasty (TKA). A mathematical model was used to evaluate the maximum error in varus and valgus alignment that could occur when cutting the tibia or femur during TKA using intramedullary (IM) guides of varying length and diameter. Minor deviations in the insertion point of IM instrumentation during TKA can result in malalignment of several degrees. This error can be minimized by careful attention to the entry point of the IM instrumentation or by increasing the IM rod diameter and length used during primary TKA.

Aged↗

Periprosthetic bone densitometry of the hip: influence of prosthetic design and hydroxyapatite coating on regional bone remodelling.

OBJECTIVE: To determine the influence of femoral hip prosthesis design and composition on regional periprosthetic bone remodelling as a function of time in asymptomatic patients. MATERIALS AND METHODS: Bone mineral density (BMD) changes surrounding two differently designed porous-coated femoral prostheses (S-ROM, n=111; and Multilocki, n=62) were determined serially over a 24 month interval. There was a subset of patients with Multilock implants that were coated with a 50 micron film of hydroxy-apatite (n=23) over the porous surface. Seven Gruen zones defined the periprosthetic bone regions (LUNAR ORTHO software). Inclusion criteria were primary implants, Harris hip scores >or=95 and no radiographic evidence of loosening. RESULTS: For the S-ROM femoral component, at 6 months all zones showed a significant decrease in BMD relative to the immediate postoperative baseline measurements; mean loss varied from 4.3% to 17.4%. At 24 months mineral change varied from -10.8% to +1% for Gruen zones 1 to 6. Gruen zone 7, the calcar, differed in that it was the site of greatest mineral loss, attaining a mean of 17% at 24 months, and it was also significantly greater than the losses registered in the other zones at that time point. For the Multilock, maximal mineral losses were registered at zones 1 and 7. There were significant differences in mineral losses between the S-ROM and Multilock implants in zones 1, 2 and 3 at 24 months; S-ROM losses of 7.3%, 10.8% and 3.5% respectively, compared to Multilock losses of 23.8%, 15.9% and 6.9% respectively. Comparison of hydroxyapatite coated and uncoated Multilock implants demonstrated significantly less loss in the coated implants in zones 1 (greater trochanter) and 7 at 24 months. Coated losses were -16.9% and 11.3% for zones 1 and 7, respectively, whereas uncoated losses were 23.8% and 20.5% respectively.

Journal Article↗

Dosimetry of hip irradiation for the prevention of heterotopic bone formation after arthroplasty.

PURPOSE: The dosimetry of hip irradiation for the prevention of heterotopic bone formation following arthroplasty is complicated by the use of custom shielding in the treatment portal, and the fact that irradiation is usually required during a 48 hour period following surgery. Both the machine output and depth dose factors of the resulting fields are modified by the presence of the shielding blocks. A simplified dosimetric approach, based on correction factors for both the output and depth dose as a function of field geometry is presented for various megavoltage energy beams. MATERIALS AND METHODS: Measurements of relative dose factors (RDF) and percentage depth dose (PDD) were carried out for different combinations of field size, block size and separation between adjacent blocks. Both RDF and PDD measurements were made in a water phantom. Ratios of RDF and PDD were obtained by dividing individual measurements or curves by the corresponding values for the open field (i.e., without blocks). The average values of these ratios constitute the correction factors to be applied for a given MU or treatment time calculation. RESULTS: Extensive RDF and PDD measurements reveal that for the field and block dimensions of interest the correction factors for RDF can be parameterized as a function of separation between two adjacent blocks and beam energy alone and the depth correction factors are additionally only a function of depth. The correction factors for depth dose are equally valid for fixed source-skin distance techniques (that use PDD) and fixed source-axis distance techniques (that use TMR). CONCLUSION: A simple model for the calculation of output in hip irradiation is presented for the situation where the use of computer-based algorithms may not be practical. The model accurately predicts the RDF of the treatment portal to within 2% and the PDD to within 2% for the range of field sizes, block sizes, block gaps and beam energies of interest ignoring other variables.

Arthroplasty, Replacement, Hip↗

Outcomes of total hip and knee replacement: preoperative functional status predicts outcomes at six months after surgery.

OBJECTIVE: To determine whether patients with knee or hip osteoarthritis (OA) who have worse physical function preoperatively achieve a postoperative status that is similar to that of patients with better preoperative function. METHODS: This study surveyed an observational cohort of 379 consecutive patients with definite OA who were without other inflammatory joint diseases and were undergoing either total hip or knee replacement in a US (Boston) and a Canadian (Montreal) referral center. Questionnaires on health status (the Short Form 36 and Western Ontario and McMaster Universities Osteoarthritis Index) were administered preoperatively and at 3 and 6 months postoperatively. Physical function and pain due to OA were deemed the most significant outcomes to study. RESULTS: Two hundred twenty-two patients returned their questionnaires. Patients in the 2 centers were comparable in age, sex, time to surgery, and proportion of hip/knee surgery. The Boston group had more education, lower comorbidity, and more cemented knee prostheses. Patients undergoing hip or knee replacement in Montreal had lower preoperative physical function and more pain than their Boston counterparts. In patients with lower preoperative physical function, function and pain were not improved postoperatively to the level achieved by those with higher preoperative function. This was most striking in patients undergoing total knee replacement. CONCLUSION: Surgery performed later in the natural history of functional decline due to OA of the knee, and possibly of the hip, results in worse postoperative functional status.

Aged↗

Bone densitometry: influence of prosthetic design and hydroxyapatite coating on regional adaptive bone remodelling.

The objective of this prospective study was to determine if bone densitometry can detect disparities in regional adaptive bone remodelling surrounding the cementless porous-coated femoral component of a hip prosthesis in two titanium alloy implants of different design . These prostheses were the S-ROM (n=69) and the Multilock (n=65). The Multilock implants consisted of two groups; 25 had a 50 micron layer of hydroxyapatite (HA) sprayed over the porous surface of the femoral component and the remaining 40 femoral components were not coated with HA. Densitometry was performed with dual energy X-ray absorptiometry (DXA) utilizing the LUNAR ORTHO software to analyse the seven Gruen zones. Bone mineral density measurements were obtained within a week of surgery as a baseline reference and at 6, 12, 24, 36 and 48 months thereafter. At 6 months there was significant mineral loss in all Gruen zones in the three prostheses. By 48 months there were differences in mineral loss between the three prostheses. In the zones adjacent to the porous surface, predominantly zones 1 and 7, the S-ROM exhibited 60% less mineral loss than the Multilock in zone 1, and there was no significant difference in zone 7. Compared to the Multilock-HA, the S-ROM lost 35% less mineral in zone 1, but the Multilock lost 70% less mineral than the S-ROM in zone 7. The Multilock-HA lost 37% and 75% less mineral than the Multilock in zones 1 and 7, respectively, i.e., hydroxyapatite coating tended to preserve bone stalk. Using the Gruen zone area measurements provided by the software, the S-ROM had significantly greater bone resorption in zone 7 at 24 months than either of the Multilocks, which did not differ from each other. In conclusion, DXA has shown differences in periprosthetic adaptive bone remodelling between implants of different design and composition as a function of time.

Absorptiometry, Photon↗