[Whole-body MR angiography: comparison of two protocols for contrast media injection].

PURPOSE: To compare two injection strategies for contrast media injection in whole-body MR angiography quantitatively and qualitatively with regard to contrast and image quality. MATERIAL AND METHODS: 40 patients were examined at 1.5 Tesla using either a single injection protocol or a double injection protocol with two separate bolus injections. Vessel regions I (supraaortic/thoracic), II (abdominal/pelvic), III (upper legs) and IV (lower legs) were examined in the following order: single injection: I, II, III, IV, double injection: I and IV after the first injection, II and III after the second bolus injection. Quantitative evaluation: SI measurements were carried out in 2 arteries per region. Contrast values were calculated. Qualitative evaluation: Evaluation of regions I-IV regarding vessel contrast, venous overlay and image quality on a five-point scale by two reviewers in consensus. The Mann-Whitney-U test was used to test the differences for significance. RESULTS: Quantitative evaluation: Using the double injection protocol, significantly higher contrast values in regions I and II and significantly lower contrast values in the subregions IIIa (upper part of III) and IVb (lower part of IV) were obtained (p < 0.05). The mean contrast values in subregions IIIb (lower part of III) and IVa (upper part of IV) were lower using the double injection protocol, but not significantly. Qualitative evaluation: Using the double injection protocol, region II was rated significantly higher (mean ratings: 3.55, 3.45 and 3.5 versus 2.7, 2.5 and 2.55; p < 0.05) and region III significantly lower (mean ratings: 3.1, 2, 2.5 versus 3.9, 3.1 and 3.55; p < 0.05) for all three examined criteria. When using the double injection protocol, ratings were significantly lower in region IV regarding vessel contrast and image quality (mean ratings: 2.4 and 2.15 versus 3.45 and 3.15; p < 0.05). The ratings regarding venous overlay in region IV showed no significant differences (mean ratings: 2.15 versus 2.75; p > 0.05). CONCLUSION: Due to the better results in the supraaortic/thoracic and abdominal/pelvic regions, the double injection protocol is preferred. However, both protocols require further improvement.

Adult↗

[How safe is magnetic resonance imaging in patients with contraceptive implants?].

When patients with an implanted contraceptive device undergo MRI, it must be ensured that the examination involves no risk to the patient (MR safety) and that the diagnosis is not affected by artifacts or the function of the device compromised (MR compatibility). Two basic types of intrauterine devices can be distinguished: the metal-containing/metal-free intrauterine device (IUD) and the hormone-containing implant, the fully metal-free intrauterine system (IUS), as well as the ESSURE insert made of stainless steel, which has been approved for use in Europe since February 2001. The metal-containing and metal-free IUDs and ESSURE are MRI compatible up to a magnetic field strength of 1.5 T. They do not interact in any relevant way with the external magnetic or high-frequency field and the temperature increase is within the physiologic range. The implants merely produce a local signal void with a shape that depends on their orientation relative to the magnetic field lines. At 3 T, only the metal-free IUD and the IUS are MRI safe in terms of the material used. In contrast, metal-containing IUDs and the ESSURE have not yet been fully evaluated in the 3 T field, which is why they represent a contraindication to MRI. No data are available on the MRI compatibility at 3 T for any of these devices.

Burns↗

Cine magnetic resonance imaging of the small bowel: comparison of different oral contrast media.

PURPOSE: To evaluate several substances regarding small bowel distension and contrast on balanced steady-state free precession (bSSFP) cine magnetic resonance (MR) images. MATERIAL AND METHODS: Luminal contrast was evaluated in 24 volunteers after oral application of two different contrast agent groups leading to either bright lumen (pineapple, blueberry juice) or dark lumen (tap water, orange juice) on T1-weighted images. Bowel distension was evaluated in 30 patients ingesting either methylcellulose or mannitol solution for limiting intestinal absorption. Fifteen patients with duodeno-jejunal intubation served as the control. Quantitative evaluation included measurement of luminal signal intensities and diameters of four bowel segments, qualitative evaluation assessed luminal contrast and distension on a five-point scale. RESULTS: Quantitative and qualitative evaluation of the four contrast agents revealed no significant differences regarding luminal contrast on bSSFP images. Quantitative evaluation revealed significantly lower (P<0.05) small bowel distension for three out of four segments (qualitative evaluation: two out of four segments) for methylcellulose in comparison to the control. Mannitol was found to be equal to the control. CONCLUSION: Oral ingestion of tap water or orange juice in combination with mannitol is recommended for cine MR imaging of the small bowel regarding luminal contrast and small bowel distension on bSSFP sequences.

Administration, Oral↗

Differentiation of prostate cancer from normal prostate tissue in an animal model: conventional MRI and dynamic contrast-enhanced MRI.

PURPOSE: To differentiate orthotopically implanted prostate cancer from normal prostate tissue using magnetic resonance imaging (MRI) and Gd-DTPA-BMA-enhanced dynamic MRI in the rat model. MATERIAL AND METHODS: Tumors were induced in 15 rats by orthotopic implantation of G subline Dunning rat prostatic tumor cells. MRI was performed 56 to 60 days after tumor cell implantation using T1-weighted spin-echo, T2-weighted turbo SE sequences, and a 2D FLASH sequence for the contrast medium based dynamic study. The interstitial leakage volume, normalized permeability and the permeability surface area product of tumor and healthy prostate were determined quantitatively using a pharmacokinetic model. The results were confirmed by histologic examination. RESULTS: Axial T2-weighted TSE images depicted low-intensity areas suspicious for tumor in all 15 animals. The mean tumor volume was 46.5 mm(3). In the dynamic study, the suspicious areas in all animals displayed faster and more pronounced signal enhancement than surrounding prostate tissue. The interstitial volume and the permeability surface area product of the tumors increased significantly by 420 % (p < 0.001) and 424 % (p < 0.001), respectively, compared to normal prostate tissue, while no significant difference was seen for normalized permeability alone. CONCLUSION: The results of the present study demonstrate that quantitative analysis of contrast-enhanced dynamic MRI data enables differentiation of small, slowly growing orthotopic prostate cancer from normal prostate tissue in the rat model.

Animals↗

Complex genital malformation in a female with congenital adrenal hyperplasia: evaluation with magnetic resonance imaging.

This is a case of complex genital malformation in a young patient with congenital adrenal hyperplasia. The magnetic resonance imaging (MRI) findings included ostium of the vagina into the urethra (common urogenital opening), prostate-like tissue surrounding the urethra, and hyperplasia of the left adrenal gland. The report provides information on the clinical findings, the MRI examination, including the applied sequences and the MR findings, and gives an overview of the disease pattern and its frequency of occurrence.

Adrenal Hyperplasia, Congenital↗

[Preoperative MRT of the breast in invasive lobular carcinoma in comparison with invasive ductal carcinoma].

PURPOSE: To evaluate the role of preoperative MRI of the breast in invasive lobular carcinoma (ILC) compared to invasive ductal carcinoma (IDC). MATERIALS AND METHODS: For one year, all patients transferred by the hospital's gynecologic outpatient service for suspicious findings in routine mammography and/or ultrasound (conventional modalities = CM) underwent preoperative MRI of the breast. Retrospective analysis of the histologic findings identified 17 patients with ILC. These were compared with 30 proven IDC patients, chosen by random. The MRI findings of these 2 patient groups were compared with regard to the detection of additional lesions. The average number of additional lesions detected by MRI was compared for significant differences between both groups using the T-test for paired samples. RESULTS: In the 17 patients with ILC, conventional modalities (CM) identified 21malignant lesions whereas MRI detected a total of 30 lesions. At least one additional lesion was detected by MRI in 7 of the 17 patients with ILC. In the 30 patients with IDC, on the other hand, MRI detected an additional lesion in three instances only. In one patient of the ILC group, MRI identified an additional lesion in the contralateral breast that had escaped detection by CM. No additional contralateral lesion was detected by MRI in any of the IDC patients. Benefit of MRI in ILC-Group: The mean numbers of detected malignant lesions differed significantly between diagnosis by MRI and CM in the ILC group (1.77 carcinomas per patient with MRI versus 1.24 with conventional modalities, T-test, p = 0.0078). Benefit of MRI in IDC-Group: although it was possible to find 1.27 carcinomas vs. 1.17 carcinomas per patient in the IDC-Group, this benefit was not statistical significant (T-test, p = 0.0831). CONCLUSION: Preoperative MRI detects multiple additional lesions compared to the ones already known by CM. The higher incidence of multiple lesions in ILC compared to IDC and the difficult diagnosis of ILC in CM might be the reason for the fact that preoperative MRI is particularly useful in patients with ILC.

Breast↗

[Value of electron beam tomography (EBT)].

Electron beam tomography (EBT) has been scientifically evaluated to a much lesser degree for non-cardiac indications than for cardiac purposes. Therefore, four groups of investigators in Berlin (2), Mannheim and Munchen, which were supported by the Deutsche Forschungsgemeinschaft (DFG), included applications outside the heart in their evaluation of EBT technology. EBT has proven useful to look for pulmonary embolism and to assess other vessels (aorta, aortic branches, and intracranial arteries). Imaging of the lung parenchyma benefits from its intrinsic high contrast and from the fast data acquisition of EBT. Limited photon efficiency, higher radiation exposure, increased noise levels and other artifacts, however, markedly reduce the value of EBT for imaging of low contrast objects compared to conventional spiral CT and multislice CT (MSCT), compromising, in particular, the morphologic depiction of parenchymal abdominal organs and the brain. Consequently, scientific studies to further evaluate EBT for scanning of the brain and parenchymal abdominal organs were not pursued. Radiation exposure for non-cardiac EBT studies is up to three times higher than that for respective spiral CT studies, and in children EBT can only be advocated in select cases. Radiation exposure for the various prospectively triggered cardiac examination protocols of EBT is lower than that for conventional coronary angiography. Radiation exposure in cardiac multislice CT exceeds severalfold that of EBT, but the dose efficiency of EBT and MSCT are similar due to higher spatial resolution and less image noise of MSCT. In addition, modifications of MSCT (ECG pulsing) can further reduce radiation exposure to the level of EBT. Technical improvements of the EBT successor scanner "e-Speed" enable faster data acquisition at higher spatial resolution. Within comparative studies, the "e-Speed" will have to prove its value and competitiveness, particularly in comparison with multislice CT. After profound scientific assessment in a multicenter evaluation supported by the Deutsche Forschungsgemeinschaft (DFG) and regardless of the specific suitability of electron beam tomography for various cardiac and some non-cardiac indications, the investigators unanimously find the electron beam tomograph Evolution C150 XP not suitable as a whole body CT scanner.

Age Factors↗

[Diagnostic value of electron-beam computed tomography (EBT). I. Cardiac applications].

Electron beam tomography (EBT) directly competes with other non-invasive imaging modalities, such as multislice computed tomography, magnetic resonance imaging, and echocardiography, in the diagnostic assessment of cardiac diseases. EBT is the gold standard for the detection and quantification of coronary calcium as a preclinical sign of coronary artery disease (CAD). Its standardized examination protocols and the broad experience with this method favor EBT. First results with multislice CT indicate that this new technology may be equivalent to EBT for coronary calcium studies. The principal value of CT-based coronary calcium measurements continues to be an issue of controversy amongst radiologists and cardiologists due to lack of prospective randomized trials. Coronary angiography with EBT is characterized by a high negative predictive value and, in addition, may be indicated in some patients with manifest CAD. It remains to be shown whether coronary angiography with multislice CT is reliable and accurate enough to be introduced into the routine work-up, to replace some of the many strictly diagnostic coronary catheterizations in Germany and elsewhere. Assessment of coronary stent patency with EBT is associated with several problems and in our opinion cannot be advocated as a routine procedure. EBT may be recommended for the evaluation of coronary bypasses to look for bypass occlusions and significant stenoses, which, however, can be equally well achieved with multislice CT. Quantification of myocardial perfusion with EBT could not replace MRI or other modalities in this field. EBT has proven to be accurate, reliable and in some instances equivalent to MRI, which is the gold standard for the quantitative and qualitative evaluation of cardiac function. Some disadvantages, not the least of which is the limited distribution of electron beam scanners, favor MRI for functional assessment of the heart.

Adult↗

[Ultra-low-dose CT to search for stones in kidneys and collecting system].

Unenhanced computed tomography (CT) has a sensitivity of 97.7 to 100 % for the detection of urolithiasis. Using a modified examination protocol, the radiation exposure of a CT examination can be reduced to the level of a single conventional radiographic view of the abdomen (ultra-low-dose CT), assuming the examination is performed on a modern multirow CT. Automatic postprocessing of thin-section images can delineate stones on coronal images. In 30 patients, ultra-low-dose CT could detect more stones (6 renal and 19 ureteral stones) than ultrasonography.

Adult↗

[Cross-section diagnosis of tumors of the kidney and prostate gland: CT and MRI].

Computed tomography (CT) and magnetic resonance imaging (MRI) underwent significant technical advances in the past ten years, especially in the diagnostic evaluation of renal tumors. Either modality can perform unenhanced and contrast enhanced imaging with high resolution display of three-dimensional data sets of the entire abdomen including the arterial and the parenchymatous perfusion phase after injection of contrast medium. Multiplanar reconstructions of these three-dimensional data allow the display in any chosen orientation. The maximum intensity projection can create CT and MR angiograms. For the diagnosis of renal tumors, both modalities offer the possibility of a detailed visualization of both the parenchyma and the arterial and venous vessels, leading to an efficient preoperative work-up. For the MRI diagnosis of the prostate cancer, the achievable accuracy depends on the applied coil technique and on the available clinical information as well as on the experience of the examiner. For the preoperative MRI staging of prostate cancer, the accuracy has been stated to be between 51 % and 97 %.

Angiography↗

Assessment of left ventricular volumes and function: intraindividual comparison of multi-slice spiral CT and electron beam CT in an animal model.

PURPOSE: To evaluate multi-slice spiral computed tomography (MSCT) for measurements of left ventricular volumes, ejection fraction (EF), and myocardial mass in comparison with electron beam CT (EBCT) as a reference method. MATERIAL AND METHODS: Six minipigs underwent both standardized contrast-enhanced MSCT (effective acquisition time per cardiac cycle 125.7+/-30.1 ms, reconstructed slice thickness 8 mm) and EBCT (acquisition time 50 ms, collimated slice thickness 8 mm). The contrast-to-noise ratio of the left ventricle was measured in each animal, and the contour sharpness of the myocardium was analyzed. Volumes (EDV, ESV, SV) ejection fraction (EF), and muscle mass were calculated by MSCT and by EBCT using the slice summation method. RESULTS: MSCT had a higher contrast-to-noise ratio and delineated the myocardial contours more sharply than EBCT. There was a close linear correlation between both modalities for all parameters (EDV: rP=0.88, ESV: rP=0.91, SV: rP=0.85, EF: rP=0.93; mass: rP=0.90; P<0.05 each). MSCT slightly overestimated ESV and slightly underestimated SV and EF compared with EBCT (P<0.05 each). CONCLUSIONS: Image quality in MSCT is superior to that of EBCT. Functional parameters correlate well between both modalities, but the accuracy of MSCT is limited by its lower temporal resolution.

Animals↗

[Modern imaging modalities in renal disease: CT and MRI].

Considerable technical advances have been made in computed tomography (CT) and magnetic resonance imaging (MRI) over the last 10 years. Both modalities allow for high-resolution imaging of the entire abdomen before as well as during the arterial and parenchymal perfusion phase after intravenous contrast medium administration. Multiplanar reconstructions of the three-dimensional source data sets yield views in any spatial orientation. Maximum intensity projections enable the generation of CT or MR angiographies as well as CT or MR urographies from delayed images. Thus, both modalities today allow for comprehensive diagnostic evaluation of renal disease by a single examination comprising detailed visualization of the parenchyma as well as of arterial and venous vessels and assessment of excretion. CT and MRI thus enable efficient preoperative diagnostic assessment in particular in patients with renal masses.

Humans↗

Use of iodine-based contrast media in digital full-field mammography--initial experience.

AIM: To investigate the use of iodine-based contrast media in digital full-field mammography. METHODS: After performing initial phantom studies, seven patients underwent digital mammography (Senographe 2000D, GE Medical Systems, Milwaukee, USA) using a specially filtered beam before as well as 60, 120, and 180 seconds after injection of 80 ml of iodine contrast medium (Ultravist 370, Schering AG, Germany). The precontrast mammograms were then subtracted from the postcontrast mammograms and the resulting images compared with a contrast-enhanced dynamic MRI study, performed on all women. RESULTS: Contrast medium accumulation within the tumors was visualized with a good quality in all cases. The conditions under which successful contrast-enhanced digital mammography can be performed were determined in phantom studies. CONCLUSIONS: Contrast-enhanced digital mammography has a potential for improving the visualization of breast tumors in mammography using special beam filtering, adjusted x-ray parameters, proper timing, and suitable subtraction software.

Breast Neoplasms↗

[MRI of prostate cancer using three different coil systems: image quality, tumor detection, and staging].

PURPOSE: To compare three MRI coil systems in terms of image quality, delineation of prostate cancer, and tumor staging. MATERIALS AND METHODS: 49 patients with prostate cancer underwent MRI at 1.5 Tesla using a combination of an endorectal coil with a phased-array body coil (combination coil) prior to radical prostatectomy. Images were reconstructed from the data sets acquired with the endorectal coil alone and from those acquired with the combined coil. In addition, 19 patients of the study patients were examined with the body phased-array coil alone without the endorectal coil. The prostate was imaged at a slice thickness of 3 mm using axial and coronal T 2 -weighted sequences and an axial T 1 -weighted sequence. Preoperative analysis of all images acquired was done to determine the accuracy of MRI in local staging of prostate cancer. An additional retrospective analysis served to compare the different coil systems in terms of overall image quality, delineation and localization of the tumor, and criteria for local staging of prostate cancer. RESULTS: Preoperative analysis showed MRI to have an accuracy of 59 % in local tumor staging. Retrospective coil-by-coil analysis demonstrated image quality and tumor delineation to be best for the combination coil and the endorectal coil. Regarding the staging criteria for transcapsular tumor extension and infiltration of adjacent organs, a significant advantage of the combination coil compared to the endorectal coil was identified only for the criterion of smooth bulging. In addition, the endorectal coil and the combination coil were found to be superior to the body phased-array coil in assessing 15 of 17 criteria for local tumor staging but the differences were not significant. CONCLUSION: In view of the achieved superior image quality, the combination coil or the endorectal coil is the preferred method for staging prostate cancer.

Aged↗

[MR angiography of the coronary arteries: comparison of the blood pool contrast medium Gadomer and Gd-DTPA in pigs].

AIM: To investigate the signal-enhancing effects of the macromolecular contrast medium Gadomer in MR angiography of the coronary arteries compared to Gd-DTPA. MATERIAL AND METHODS: A total of 15 MRI examinations of the heart were performed in pigs at 1.5 T using a pulse-triggered, segmented 3D FLASH sequence with data acquisition during breathhold before and up to 30 min after contrast medium injection. Gadomer was investigated at two doses (0.05 and 0.1 mmol Gd/kg), Gd-DTPA at one (0.3 mmol Gd/kg) (n = 5 examinations per dose). Standard sequences without magnetization preparation were supplemented by sequences with magnetization saturation applied before data acquisition before and immediately after contrast medium injection. Analysis comprised quantitative determination of blood and myocardium signal to noise (S/N) and contrast to noise (C/N) and qualitative assessment of several parameters of image quality and coronary artery visualization. RESULTS: Gadomer leads to a significant C/N increase between blood and myocardium compared to the unenhanced examination and the increase is longer-lasting than that produced by Gd-DTPA (Gd-DTPA: only directly after injection; Gadomer: up to 5 min post injection at 0.05 mmol Gd/kg, up to 10 min at 0.1 mmol Gd/kg). The qualitative evaluation shows that visualization of the coronary arteries and branch vessels is significantly better with Gadomer at both doses than with Gd-DTPA. Magnetization saturation increases the C/N in combination with Gd-DTPA and at the higher dose of Gadomer with the latter producing a higher increase in C/N values. CONCLUSION: Gadomer is a suitable contrast medium for MR angiography of the coronary arteries with the dose of 0.1 mmol Gd/kg being superior to 0.05 mmol Gd/kg due to a longer imaging window.

Animals↗

[Superparamagnetic iron oxide particles: current state and future development].

A wide range of applications for superparamagnetic iron oxide (SPIO) particles as contrast media for MRI has emerged over the last 15 years. SPIO particles can be manufactured with different particle sizes and surface coatings. Large SPIO particles (50-150 nm) predominantly produce a signal decrease or T2 -shortening and are used as contrast media for MRI of the liver and spleen. They have a high accuracy, especially in detecting liver metastases (approved for clinical use: AMI-25 (Endorem or Ferridex), SHU-555A (Resovist)). Smaller particles (about 20 nm in diameter) show a different organ distribution and have a potential for improving noninvasive lymph node assessment or characterizing vulnerable atherosclerotic plaques (in clinical trials: AMI-227 [Sinerem or Combidex]). Particles with an optimized T1-relaxivity and prolonged intravascular circulation time can be used as blood pool contrast media for MR angiography. The currently investigated indications are MR angiography of the trunk, peripheral vessels, and coronary arteries (e.g., SHU-555 C (Supravist), VSOP-C 184). Other applications of small SPIO particles include MRI of the bone marrow and the determination of perfusion parameters in tumors or other tissues like the myocardium. SPIO particles with a modified coat can be used in so-called molecular imaging, such as receptor-directed imaging, cell labeling for in-vivo monitoring of cell migration, e.g., stem cell labeling, and labeling of gene constructs for localization in genetic therapy. In tumor therapy SPIO particles can serve as mediators for hyperthermia. SPIO is a powerful MR contrast medium with manifold applications ranging from diagnostic imaging to molecular medicine.

Animals↗