PubMed Health⌕ Search

Biomedical subjects

M Tecotzky

Publications and source records attributed to M Tecotzky.

3 recordsLinked to original sources

A Monte Carlo study of x-ray fluorescence in x-ray detectors.

Advances in digital x-ray detector systems have led to a renewed interest in the performance of x-ray phosphors and other detector materials. Indirect flat panel x-ray detector and charged coupled device (CCD) systems require a more technologically challenging geometry, whereby the x-ray beam is incident on the front side of the scintillator, and the light produced must diffuse to the back surface of the screen to reach the photoreceptor. Direct detector systems based on selenium have also enjoyed a growing interest, both commercially and academically. Monte Carlo simulation techniques were used to study the x-ray scattering (Rayleigh and Compton) and the more prevalent x-ray fluorescence properties of seven different x-ray detector materials, Gd2O2S, CsI, Se, BaFBr, YTaO4, CaWO4, and ThO2. The redistribution of x-ray energy, back towards the x-ray source, in a forward direction through the detector, and lateral reabsorption in the detector was computed under monoenergetic conditions (1 keV to 130 keV by 1 keV intervals) with five detector thicknesses, 30, 60, 90, 120, and 150 mg/cm2 (Se was studied from 30 to 1000 mg/cm2). The radial distribution (related to the point spread function) of reabsorbed x-ray energy was also determined. Representative results are as follows: At 55 keV, more (31.3%) of the incident x-ray energy escaped from a 90 mg/cm2Gd2O2S detector than was absorbed (27.9%). Approximately 1% of the total absorbed energy was reabsorbed greater than 0.5 mm from the primary interaction, for 90 mg/cm2 CsI exposed at 100 kVp. The ratio of reabsorbed secondary (fluorescence + scatter) radiation to the primary radiation absorbed in the detectors (90 mg/cm2) (S/P) was determined as 10%, 16%, 2%, 12%, 3%, 3%, and 0.3% for a 100 kVp tungsten anode x-ray spectrum, for the Gd2O2S, CsI, Se, BaFBr, YTaO4, CaWO4, and ThO2 detectors, respectively. The results indicate significant x-ray fluorescent escape and reabsorption in common x-ray detectors. These findings suggest that x-ray fluorescent radiation redistribution should be considered in the design of digital x-ray imaging systems.

Biophysical Phenomena↗

Binary screen detector system for single-pulse dual-energy radiography.

Dual-energy radiographic acquisition performed with a single pulse of x rays has been limited to use of stacked detectors such as photo-stimulable phosphor plates. In this study, a binary screen system is introduced that enables single-pulse dual-energy acquisition with nonstacked detectors such as charge-coupled devices (CCDs). Two x-ray phosphors with different K edges, designed to emit light of different wavelengths, were bound together in a single screen. Two CCD cameras, each sensitive to the respective wavelengths emitted by each phosphor, are proposed to be coupled to the binary screen. Optical isolation and detection of the optical emissions from the screen would enable simultaneous acquisition of both low- and high-energy images, which can then be used in dual-energy subtraction. Computer simulation results and experimentally acquired images suggest that the binary screen approach may be a viable alternative to stacked detector technology for dual-energy radiographic imaging.

Computer Simulation↗

Dual-energy mammography: a detector analysis.

Dual-energy mammography acquisition scenarios employing single-shot techniques are examined using computer simulation. A figure of merit of the signal-to-noise ratio squared over the glandular dose was chosen for the optimization task due to its exposure independence. Doses were evaluated using Monte Carlo techniques. The effects of kilovoltage, prepatient filtration, front detector thickness, mid-detector filtration thickness and composition were studied. Of the six detector pairs studied (Y2O2S/Gd2O2S, SrFBr/BaFBr, Y2O2S/LaOBr, Y2O2S/CaWO4, Y2O2S/YTaO4, and Y2O2S/LuTaO4), Y2O2S/Gd2O2S and SrFBr/BaFBr were found to be the best combinations. The effects of scatter and signal quantization were also examined. An alternative display technique whereby the tissue-subtracted (i.e., calcium) image is colorized and overlaid onto the conventional mammogram is introduced.

Color↗