Fibroblast and osteoblast adhesion and morphology on calcium phosphate surfaces.

Implant loosening in bone fixation is an unresolved complication associated with internal fixation. It is generally accepted that this problem can be overcome by modifying the implant/bone interface for improved osseointegration. This is achieved, in part, by hydroxyapatite (HA) or tricalcium phosphate coatings. Unfortunately, the benefits of these coatings are constrained by not only the generally low strength of their adhesion to the implant surface but also the limited cohesion within their layers. Anodic Plasma-chemical treatment (APC) has been developed to incorporate electrolytes and produce coatings with various microtopographies and strong adhesion to implants. In this in vitro study fibroblast and osteoblast morphologies and adhesion to various substrates were evaluated using qualitative and quantitative methods. The substrates were Thermanox plastic and commercially pure titanium. The latter were surface-treated using several different methods: conventional anodisation, plasma spraying of HA and anodic plasma-chemical (APC) treatment in an electrolyte solution containing either calcium and phosphate (APC-CaP) or phosphoric acid (APC-P). Both osteoblasts and fibroblasts showed extensive cell spreading, total cell area and greatest amount of adhesion, with defined adhesion patterns on the Thermanox plastic, anodised titanium, and the two APC-CaP substrates. With fibroblasts, almost no cell spreading and very low adhesion, was observed in cells cultured on the APC-P and HA surfaces. The extent of cell spreading correlated with the area of focal adhesions as assessed by the amount of vinculin labelling. The Thermanox plastic, anodised titanium, and the two APC-CaP substrates were the most cytocompatible substrates with regard to this in vitro evaluation.

Journal Article↗

Optical grating coupler biosensors.

By incorporating a grating in a planar optical waveguide one creates a device with which the spectrum of guided lightmodes can he measured. When the surface of the waveguide is exposed to different solutions, the peaks in the spectrum shift due to molecular interactions with the surface. Optical waveguide lightmode spectroscopy (OWLS) is a highly sensitive technique that is capable of real-time monitoring of these interactions. Since this integrated optical method is based on the measurement of the polarizability density (i.e., refractive index) in the vicinity of the waveguide surface, radioactive, fluorescent or other kinds of labeling are not required. In addition, measurement of at least two guided modes enables the absolute mass of adsorbed molecules to be determined. In this article, the technique will be described in some detail, and applications from different areas will be discussed. Selected examples will be presented to demonstrate how monitoring the modification of different metal oxides with polymers and the response of the coated oxides to biofluids help in the design of novel biomaterials; how OWLS is useful for accurate bioaffinity sensing, which is a key issue in the development of new drugs; and how the quantitative study of protein-DNA/RNA and cell surface interactions can enhance the understanding of processes in molecular and cellular biology.

Adsorption↗

Comparative investigation of the surface properties of commercial titanium dental implants. Part I: chemical composition.

The surfaces of five commercially available titanium implants (Brånemark Nobel Biocare, 3i ICE, 3i OSSEOTITE, ITI-TPS, and ITI-SLA) were compared by scanning electron microscopy, X-ray photoelectron spectroscopy, time-of-flight secondary ion mass spectroscopy. All five implant types were screw-shaped and fabricated from commercially pure (cp) titanium, but their surface properties differed both as regards surface morphology and surface chemical composition. The macro- and microstructure of the implant surfaces were investigated by scanning electron microscopy. The surfaces chemical composition was determined using the surface-sensitive analytical techniques of X-ray photoelectron spectroscopy and time-of-flight secondary ion spectrometry. Surface topographies were found to reflect the type of mechanical/chemical fabrication procedures applied by the manufacturers. The titanium oxide (passive) layer thickness was similar (5-6 nm) and typical for oxide films grown at or near room temperature. A variety of elements and chemical compounds not related to the metal composition were found on some implant types. They ranged from inorganic material such as sodium chloride to specific organic compounds believed to be due to contamination during fabrication or storage. The experimental findings are believed to make a contribution to a better understanding of the interplay between industrial fabrication procedure and physico-chemical implant surface properties.

Journal Article↗

Biodegradable polymer/hydroxyapatite composites: surface analysis and initial attachment of human osteoblasts.

Biodegradable polymer/hydroxyapatite (HA) composites have potential application as bone graft substitutes. Thin films of polymer/HA composites were produced, and the initial attachment of primary human osteoblasts (HOBs) was assessed to investigate the biocompatibility of the materials. Poly(epsilon-caprolactone) (PCL) and poly(L-lactic acid) (PLA) were used as matrix materials for two types of HA particles, 50-microm sintered and submicron nonsintered. Using ESEM, cell morphology on the surfaces of samples was investigated after 90 min, 4 h, and 24 h of cell culture. Cell activity and viability were assessed after 24 h of cell culture using Alamar blue and DNA assays. Surface morphology of the polymer/HA composites and HA exposure were investigated using ESEM and EDXA, respectively. ESEM enabled investigation of both cell and material surface morphology in the hydrated condition. Combined with EDXA it permitted chemical and visual examination of the composite. Differences in HA exposure were observed on the different composite surfaces that affected the morphology of attached cells. In the first 4 h of cell culture, the cells were spread to a higher degree on exposed HA regions of the composites and on PLA than they were on PCL. After 24 h the cells were spread equally on all the samples. The cell activity after 24 h was significantly higher on the polymer/HA composites than on the polymer films. There was no significant difference in the activity of the cells on the various composite materials. However, cells on PCL showed higher activity compared to those on PLA. A polymer surface exhibiting "point exposure" of HA appeared to provide a novel and favorable substrate for primary cell attachment. The cell morphology and activity results indicate a favorable cell/material interaction and suggest that PLA and PCL and their composites with HA may be candidate materials for the reconstruction of bony tissue. Further investigations regarding long-term biomaterial/cell interactions and the effects of acidic degradation products from the biodegradable polymers are required to confirm their utility.

Bone Substitutes↗

Feasibility study of an online toxicological sensor based on the optical waveguide technique.

Morphological properties of the cells often change as an early response to the presence of a pharmacologically acting toxic substance [Etcheverry, S.B., Crans, D.C., Keramidas, A.D., Cortizo, A.M., Arch. Biochem. Biophys. 338 (1997) 7-14]. Recently it has been shown that living animal cell adhesion and spreading can be monitored online and quantitatively via the interaction of the cells with the evanescent electromagnetic field present at the surface of an optical waveguide [Ramsden, J.J., Li, S.Y., Heinzle, E., Prinosil, J.E. Cytometry 19 (1995) 97-102]. In the present study, optical waveguide lightmode spectroscopy (OWLS) and confocal laser scanning microscopy (CLSM), which provides information about the shape of the cells at the surface, were compared under identical experimental conditions. This allowed for the correlation between the cell-shape information from CLSM and the cell-surface interaction measurements from OWLS. The proposed design of the microsystem sensor involves the establishment of a cell layer on the surface of the waveguide and the subsequent online measurement of the morphological response of the cells to various toxic substances. In the present study, the setup was evaluated using cells from an osteoblastic MC 3T3-E1 cell line, and sodium hypochlorite was used as model toxic substance. Comparing the OWLS signal to the morphological response measured by CLSM reveals that OWLS is effective in monitoring not only cell attachment and spreading but also the cellular response to toxic compounds (i.e. by means of change in cell morphology). For the model toxin, the OWLS measurements indicate that, at concentrations above 0.01%, the cells exhibit a clearly discernable morphological effect (i.e. a decrease in average cell contact area). Thus, the potential of an on-line sensor based on OWLS to applications in toxicology, pharmacy and biocompatibility was demonstrated.

3T3 Cells↗

Advantages of stereo imaging of metallic surfaces with low voltage backscattered electrons in a field emission scanning electron microscope

High emission current backscattered electron (HC-BSE) stereo imaging at low accelerating voltages (</= 5 keV) using a field emission scanning electron microscope was used to display surface structure detail. Samples of titanium with high degrees of surface roughness, for potential medical implant applications, were imaged using the HC-BSE technique at two stage tilts of + 3 degrees and - 3 degrees out of the initial position. A digital stereo image was produced and qualitative height, depth and orientation information on the surface structures was observed. HC-BSE and secondary electron (SE) images were collected over a range of accelerating voltages. The low voltage SE and HC-BSE stereo images exhibited enhanced surface detail and contrast in comparison to high voltage (> 10 keV) BSE or SE stereo images. The low voltage HC-BSE stereo images displayed similar surface detail to the low voltage SE images, although they showed more contrast and directional sensitivity on surface structures. At or below 5 keV, only structures a very short distance into the metallic surface were observed. At higher accelerating voltages a greater appearance of depth could be seen but there was less information on the fine surface detail and its angular orientation. The combined technique of HC-BSE imaging and stereo imaging should be useful for detailed studies on material surfaces and for biological samples with greater contrast and directional sensitivity than can be obtained with current SE or BSE detection modes.

Journal Article↗

Osteoblast proliferation and differentiation on dentin slices are modulated by pretreatment of the surface with tetracycline or osteoclasts.

BACKGROUND: Implant surface roughness and chemical composition, as well as other factors, affect the ability of osteogenic cells to form bone adjacent to an implant. The same principles may also apply to the tooth root and some reports have shown that surface modification of the root may lead to improved restoration of the periodontal apparatus. The most common of these surface modification techniques involves demineralization with citric acid or treatment with tetracycline to expose collagen fibrils. In addition, during normal bone remodeling, osteoclasts demineralize the extracellular matrix, leaving resorption pits and exposed collagen fibrils. In this study, the effect of different dentin surface-preparation techniques on osteoblasts were compared. METHODS: Slices of sperm whale dentin were mechanically polished and surfaces were treated with tetracycline-HCl (TCN) or were cultured with mouse bone marrow cells to create a surface with osteoclast (OC) resorption pits or left untreated. Profilometry, x-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM) were used to evaluate the 3 different dentin surfaces. MG63 osteoblast-like cells were cultured on the 3 different surfaces and the effect of dentin surface preparation technique on MG63 cell proliferation (cell number), differentiaton (alkaline phosphatase specific activity of isolated cells and cell layer lysates; osteocalcin production), and local factor production (transforming growth factor (TGF)-beta1 and prostaglandin E2 (PGE2) compared. RESULTS: Profilometry showed the polished and TCN surfaces were smooth with comparable Ra values, whereas the OC surfaces were slightly rougher due to resorption pits which covered 3.7% of the surface. XPS measurements showed that TCN treatment reduced the Ca and P content of the surface, indicating that it had dissolved the mineral. Osteoclast-resorption also reduced the Ca and P content, but to a lesser extent. MG63 cell proliferation on polished dentin and tissue culture polystyrene was equivalent. In contrast, cells grown on the TCN- and OC-treated surfaces exhibited increased proliferation. No effect of surface treatment on cell alkaline phosphatase activity was observed, but activity in the cell layer lysates was increased on the TCN- and OC-treated surfaces. Osteocalcin production was reduced on all dentin surfaces, but the greatest reduction was found on the TCN-treated surface. Production of both TGF-beta1 and PGE2 was increased on the treated surfaces. All effects were greatest in cultures grown on the TCN-treated dentin. CONCLUSIONS: These data indicate that demineralization of the dentin surface promotes proliferation of osteoblasts and early differentiation events like production of alkaline phosphatase and autocrine mediators such as PGE2 and TGF-beta1. However, later differentiation events like osteocalcin production are decreased. Osteoclast-mediated bone resorption elicits similar responses; less than 4% of the dentin surface resulted in approximately 75% of the response caused by TCN treatment. These observations suggest that greater attention should be paid to the effects of osteoclastic resorption in designing methods for enhancing bone and cementum formation adjacent to root surfaces.

Alkaline Phosphatase↗

Surface characterization of implant materials c.p. Ti, Ti-6Al-7Nb and Ti-6Al-4V with different pretreatments.

The biocompatibility of commercially pure titanium and its alloys is closely related to their surface properties, with both the composition of the protecting oxide film and the surface topography playing an important role. Surfaces of commercially pure titanium and of the two alloys Ti-6Al-7Nb and Ti-6Al-4V (wt %) have been investigated following three different pretreatments: polishing, nitric acid passivation and pickling in nitric acid-hydrogen fluoride. Nitric acid treatment is found to substantially reduce the concentration of surface contaminants present after polishing. The natural 4-6 nm thick oxide layer on commercially pure titanium is composed of titanium oxide in different oxidation states (TiO2, Ti2O3 and TiO), while for the alloys, aluminium and niobium or vanadium are additionally present in oxidized form (Al2O3, Nb2O5 or V-oxides). The concentrations of the alloying elements at the surface are shown to be strongly dependent on the pretreatment process. While pickling increases the surface roughness of both commercially pure titanium and the alloys, different mechanisms appear to be involved. In the case of commercially pure titanium, the dissolution rate depends on grain orientation, whereas in the case of the two alloys, selective alpha-phase dissolution and enrichment of the beta-phase appears to occur.

Journal Article↗

Characterization of anodic spark-converted titanium surfaces for biomedical applications.

The aim of the present study was to characterize the surface morphology, microstructure and the chemical composition of anodic spark-converted titanium surfaces. The coatings were prepared in an electrochemical cell by the anodic spark deposition technique in an aqueous solution of Ca(H2PO4)2. The coatings were characterized by X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), electron probe microanalysis (EPMA) and X-ray diffraction (XRD). The properties of the coatings are described in terms of morphology.

Journal Article↗

The implant material, Ti6Al7Nb: surface microstructure, composition and properties.

The excellent biocompatibility of titanium and its alloys is intimately related with the properties of the surface in contact with the biological environment, and therefore it is closely connected with the stable, passivating oxide layer that forms on its surface. In the present paper, the oxide layer on the alloy Ti6Al7Nb has been characterized using X-ray photoelectron spectroscopy, scanning Auger microscopy and pH-dependent lateral force microscopy. The alloying elements Al and Nb are incorporated in the oxide layer and detected in their most stable oxidized form, as Al2O3 and Nb2O5. Their distribution in the oxide reflects the underlying alpha-beta microstructure, with enrichment of Al in the alpha- and of Nb in the beta-phase (determined by electron microprobe). Friction measurements (lateral force microscopy) indicate slightly different, pH-dependent, lateral forces above the alpha- and beta-phase structures that point to small local variations in surface charges.

Journal Article↗

Phosphorylcholine-containing polyurethanes for the control of protein adsorption and cell attachment via photoimmobilized laminin oligopeptides.

In this study, we synthesized a biomaterial whose surface inhibits non-specific protein and cell attachment. The polymer was designed to mimic the external cell plasma membrane properties through the introduction of particular chemical constituents of the cell membrane: phospholipid polar headgroups. This was done by copolymerizing phosphorylcholine (PC) groups into a polyurethane polymer backbone (PCPUR). Peptides known to induce specific cell attachment were subsequently bound to the surface of this copolymer in a photoadressible manner to obtain surfaces that allowed the attachment of cells in a specific pattern. Two polymers with different phosphorylcholine concentrations were synthesized and their bulk and surface properties were characterized through differential scanning calorimetry, wettability measurements, angle-resolved X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry. Protein and lipid adsorption investigation using optical waveguide light mode spectroscopy showed that the irreversible adsorption of both proteins and lipids is drastically reduced as a result of simultaneous contributions of the PC groups, molecular mobility and strong hydrophilicity of the polymers. Consequently, this leads to a marked reduction in the cellular attachment response, which further decreases with increasing PC concentration. Finally, when the polymer surface was photo-derivatized, attachment of the neural NG108-15 cell line occurred only on the areas of the PCPUR where the laminin CDPGYIGSR peptide sequence was photoimmobilized. Cell attachment was nevertheless found to be non-specific with respect to the peptide sequence used and reasons for such results are therefore discussed.

Adsorption↗

Immobilization of the cell-adhesive peptide Arg-Gly-Asp-Cys (RGDC) on titanium surfaces by covalent chemical attachment.

Surface modification of acid-pretreated titanium with 3-aminopropyltriethoxylsilane (APTES) in dry toluene resulted in covalently bonded siloxane films with surface coverage that was relatively controllable by regulating the reaction conditions. A hetero-bifunctional cross-linker, N-succinimidyl-3-maleimidopropionate (SMP), reacted with the terminal amino groups, forming the exposed maleimide groups. Finally, a model cell-binding peptide, Arg-Gly-Asp-Cys (RGDC), was immobilized on the surface through covalent addition of the cysteine thiol groups to the maleimide groups. X-ray photoelectron spectroscopy, radiolabelling techniques, and ellipsometry were used to quantify and characterize the modified surfaces.

Journal Article↗

Surface activation of polyetheretherketone (PEEK) and formation of calcium phosphate coatings by precipitation.

Plasma activation of polyetheretherketone (PEEK) surfaces and the influence on coating formation in a supersaturated calcium phosphate solution was investigated in this study. It was observed that plasma treatment in a N2/O2 plasma had a significant effect on the wettability of the PEEK surface. The contact angle decreased from 85 degrees to 25 degrees after plasma treatment. Cell culture testing with osteoblastic cell lines showed plasma activation not to be disadvantageous to cell viability. X-ray photoelectron spectroscopy (XPS) analysis was performed to characterize the chemical composition of the PEEK surfaces. It was observed that the O1s intensity increased with plasma activation time. At the C1s peak the appearance of a shoulder at higher binding energies was observed. Coating of PEEK was performed in a supersaturated calcium phosphate solution. Coating thicknesses of up to 50 microm were achieved after 24 days of immersion. Plasma activation followed by nucleation in a highly saturated hydroxyapatite solution had a positive effect on the growth rate of the layer on PEEK. Chemical analysis revealed that the coating consists of a carbonate-containing calcium phosphate.

Journal Article↗

Wavelength-dependent roughness: a quantitative approach to characterizing the topography of rough titanium surfaces.

Topographies of grit-blasted, etched, grit-blasted and etched, and microfabricated and etched surfaces of commercially pure titanium have been investigated. Such surface topographies vary across the scale range of interest for dental implants, extending from nanometers to millimeters. The complete characterization of topography requires the use of complementary methods. This study compared the topographic characterization methods of non-contact laser profilometry, interference microscopy, stereo-scanning electron microscopy (stereo-SEM), and atomic force microscopy. Non-contact laser profilometry was shown to be a useful method to characterize topographic features in the micron to millimeter range, whereas interference microscopy and stereo-SEM can be employed down to the submicron range. Stereo-SEM is particularly useful for quantifying topographies with complex, strongly corrugated ("sharp"), and high-aspect-ratio features and was shown to be complementary to non-contact laser profilometry and interference microscopy. Because of tip-related envelope problems, atomic force microscopy was not found to be suitable for the type of surfaces investigated in this study. Independent of the method used, the commonly used "integral" amplitude roughness parameters, such as Ra, Rq, or Rt, were often of limited value in the description of actual implant surfaces. The application of the wavelength-dependent roughness approach was shown to be an effective method for the description of surface topographies in the complete range of characteristic roughness and is also a useful means of examining the effects of surface treatment processes.

Analysis of Variance↗