PubMed Health⌕ Search

Biomedical subjects

M V Carneiro

Publications and source records attributed to M V Carneiro.

2 recordsLinked to original sources

Soluble transferrin receptor in sickle cell diseases: correlation with spleen function.

OBJECTIVE: To correlate spleen function with soluble transferrin receptor (sTfR) levels and red cell ferritin (RCF) values in patients with sickle cell diseases. DESIGN: Prospective study. LOCATION: University Hospital, School of Medical Sciences, State University of Campinas; a tertiary hospital. PARTICIPANTS: 60 patients with sickle cell diseases, in a steady state, who had not received blood transfusions for 3 months; 28 normal individuals with no clinical or laboratory signs of anemia. MEASUREMENTS: Determination of serum iron, transferrin iron-binding capacity, serum ferritin, RCF and sTfR. Evaluation of spleen function: erythrocytes with pits were quantified. RESULTS: Patients with sickle cell anemia had sTfR levels significantly higher than in normal individuals or those with HbSC (p=0.0001) and there was an inverse correlation between sTfR and fetal Hb (p=0.0016). RCF values were significantly higher in sickle cell anemia patients than in normal individuals or those with HbSC (p=0.0001), and there was a correlation between RCF and pitted erythrocytes (p=0.0512). CONCLUSION: The association between sTfR and fetal Hb confirms the contribution of fetal Hb to improving the hemolytic state by minimizing the consequent reactive erythrocyte expansion. High sTfR levels are not related to the degree of spleen function deficiency seen in sickle cell disease patients. The deficiency in the exocytosis process of the spleen occurring in sickle cell anemia patients may contribute to their accumulation of RCF.

Adult↗

Intraaortic balloon pump support during coronary angioplasty. Initial experience.

OBJECTIVE: To evaluate the use of the intraaortic balloon (IAoB) in association with coronary angioplasty in high-risk patients. METHODS: Fourteen high-risk patients unresponsive to clinical therapy and with formal contraindication to surgical revascularization were treated by coronary angioplasty, most of which was followed by stenting. All procedures were performed with circulatory support with the IAoB. This study reports the early results and the late findings after 12 months of follow-up. Six patients had multivessel coronary disease; of these, four had left main equivalent lesions and two had unprotected left main coronary artery disease, one of whom had severe "end-vessel" stenosis and the other was a patient with Chagas' disease with single-vessel lesion. Eleven patients had a left ventricular ejection fraction < 30%. RESULTS: In 100% of the patients, the procedures were initially successful. Two patients had severe bleeding during the withdrawal of the left femoral sheath. At the end of twelve months, 4 patients were asymptomatic and the others were clinically controlled. There were two late deaths in the 7th and 11th months. CONCLUSION: The combined use of the intraaortic balloon pump and percutaneous coronary angioplasty in high-risk patients with acute ischemic syndromes provides the necessary hemodynamic stability to successfully perform the procedures.

Aged↗