PubMed Health⌕ Search

Biomedical subjects

M V Rocco

Publications and source records attributed to M V Rocco.

43 records · Page 3Linked to original sources

Risk factors for hypertension in chronic hemodialysis patients: baseline data from the HEMO study.

A cross-sectional analysis was performed to determine risk factors associated with hypertension in 1,238 chronic hemodialysis patients upon enrollment into the HEMO Study. The mean pre- and post-dialysis systolic blood pressure were 152.4 +/- 25.0 (mean +/- SD) and 137.8 +/- 24.6 mm Hg, respectively. The mean pre- and post-dialysis diastolic blood pressures were 82.1 +/- 14.8 and 74.7 +/- 13.8 mm Hg, respectively. Less than 30% of the study cohort had blood pressures that were normotensive by JNC VI guidelines. Risk factors associated with higher pre- and post-dialysis systolic blood pressures included the presence of diabetes mellitus, older age, increased number of prescribed antihypertensive medications, lower hematocrit, and absence of arrhythmias. Variables associated with higher pre- and post-dialysis diastolic blood pressures included younger age, increased number of prescribed anti-hypertensive medications and absence of arrhythmias. There was also a nonlinear relationship between blood pressure and prescribed total ultrafiltration volume. A total ultrafiltration volume of >2.5 kg was associated with an elevation in pre-dialysis systolic and diastolic blood pressures. A total ultrafiltration volume of < or =2.5 kg was associated with an elevation in post-dialysis systolic and diastolic blood pressures. These data on ultrafiltration volume suggest that higher pre-dialysis blood pressures may be associated with excessive interdialytic weight gains due to patient noncompliance with fluid restriction and that higher post-dialysis blood pressures may be associated with a prescribed dry weight that is higher than the patient's true dry weight. Better management of these parameters may improve the prevalence and severity of hypertension in this population.

Clinical Trials as Topic↗

Measurement of continuous ambulatory peritoneal dialysis prescription adherence using a novel approach.

OBJECTIVE: The purpose of the study was to test a novel approach to monitoring the adherence of continuous ambulatory peritoneal dialysis (CAPD) patients to their dialysis prescription. DESIGN: A descriptive observational study was done in which exchange behaviors were monitored over a 2-week period of time. SETTING: Patients were recruited from an outpatient dialysis center. PARTICIPANTS: A convenience sample of patients undergoing CAPD at Piedmont Dialysis Center in Winston-Salem, North Carolina was recruited for the study. Of 31 CAPD patients, 20 (64.5%) agreed to participate. MEASURES: Adherence of CAPD patients to their dialysis prescription was monitored using daily logs and an electronic monitoring device (the Medication Event Monitoring System, or MEMS; APREX, Menlo Park, California, U.S.A.). Patients recorded in their logs their exchange activities during the 2-week observation period. Concurrently, patients were instructed to deposit the pull tab from their dialysate bag into a MEMS bottle immediately after performing each exchange. The MEMS bottle was closed with a cap containing a computer chip that recorded the date and time each time the bottle was opened. RESULTS: One individual's MEMS device malfunctioned and thus the data presented in this report are based upon the remaining 19 patients. A significant discrepancy was found between log data and MEMS data, with MEMS data indicating a greater number and percentage of missed exchanges. MEMS data indicated that some patients concentrated their exchange activities during the day, with shortened dwell times between exchanges. Three indices were developed for this study: a measure of the average time spent in noncompliance, and indices of consistency in the timing of exchanges within and between days. Patients who were defined as consistent had lower scores on the noncompliance index compared to patients defined as inconsistent (p = 0.015). CONCLUSIONS: This study describes a methodology that may be useful in assessing adherence to the peritoneal dialysis regimen. Of particular significance is the ability to assess the timing of exchanges over the course of a day. Clinical implications are limited due to issues of data reliability and validity, the short-term nature of the study, the small sample, and the fact that clinical outcomes were not considered in this methodology study. Additional research is needed to further develop this data-collection approach.

Adult↗

Intermediate outcomes by race and ethnicity in peritoneal dialysis patients: results from the 1997 ESRD Core Indicators Project. National ESRD Core Indicators Workgroup.

BACKGROUND: Hispanics are the fastest growing minority group in the United States, and approximately 10% of all end-stage renal disease (ESRD) patients are Hispanic. Few data are available, however, regarding dialysis adequacy and anemia management in Hispanic patients receiving peritoneal dialysis in the U.S. METHODS: Data from the Health Care Financing Administration (HCFA) ESRD Core Indicators Project were used to assess racial and ethnic differences in selected intermediate outcomes for peritoneal dialysis patients. RESULTS: Of the 1219 patients for whom data were available from the 1997 sample, 9% were Hispanic, 24% were non-Hispanic blacks, and 59% were non-Hispanic whites. Hispanics were more likely to have diabetes mellitus as a cause of ESRD compared to blacks or whites, and both Hispanics and blacks were younger than white patients (both p < 0.001). Although whites had higher weekly Kt/V and creatinine clearance values compared to blacks or Hispanics (p < 0.05), blacks had been dialyzing longer (p < 0.01) and were more likely to be anuric compared to the other two groups (p < 0.001). Blacks had significantly lower mean hematocrit values (p < 0.001) and a greater proportion of patients who had a hematocrit level less than 28% (p < 0.05) compared to Hispanics or whites, despite receiving significantly larger weekly mean epoetin alfa doses (p < 0.05) and having significantly higher mean serum ferritin concentrations (p < 0.01). Multivariate logistic regression analysis revealed significant differences by race/ethnicity for experiencing a weekly Kt/V urea < 2.0 and hypertension, but not for other intermediate outcomes examined (weekly creatinine clearance < 60 L/week/1.73 m2, Hct < 30%, and serum albumin < 3.5/3.2 g/dL). CONCLUSION: Hispanics had adequacy values similar to blacks and anemia parameters similar to whites. Additional studies are needed to determine the etiologies of the differences in intermediate outcomes by racial and ethnic groupings in peritoneal dialysis patients.

Adolescent↗

Nutritional markers during peritoneal dialysis: data from the 1998 Peritoneal Dialysis Core Indicators Study.

OBJECTIVE: This analysis explores the nutritional status of adult U.S. peritoneal dialysis (PD) patients. DESIGN: The Peritoneal Dialysis Core Indicators Study is a prospective cross-sectional prevalence survey describing the care provided to a random sample of adult U.S. PD patients. METHODS AND POPULATION: Prevalence data were collected from a national random sample of 1381 adult PD patients participating in the United States End Stage Renal Disease (ESRD) program. RESULTS: The median age of these patients was 55 years, 61% were Caucasian; the leading cause of ESRD was diabetes mellitus. Age, sex, size, peritoneal permeability, dialysis adequacy, and nutritional indices did not differ between patients on continuous ambulatory PD and patients on automated PD. The dialysis prescriptions employed achieved mean weekly Kt/V urea (wKt/V) and creatinine clearance (wCCr) values of 2.22 +/- 0.57 and 67.8 +/- 22.5 L/1.73 m2/week, respectively. The PD patients were large, with a mean body weight of 77 +/- 21 kg and body mass index (BMI) of 27 +/- 8.6 kg/m2. The mean serum albumin of these patients was 3.5 +/- 0.51 g/dL, and 43% of values fell below the National Kidney Foundation Dialysis Outcomes Quality Initiative's desired range. The PD patients had a normalized protein equivalent of nitrogen appearance (nPNA) of 1.0 +/- 0.57 g/kg/day, a normalized creatinine appearance rate (nCAR) of 17 +/- 7.3 mg/kg/day, and an estimated lean body mass (%LBM) of 62% +/- 18% of body weight. Serum albumin correlated positively with patient size, nCAR, and nPNA, but negatively with age, the presence of diabetes mellitus, female gender, erythropoietin dose, the creatinine dialysate-to-plasma ratio results of peritoneal equilibration testing, and the dialysis portion of the wCCr. The duration of ESRD experience correlated negatively with both serum albumin and patient size, although these relationships were complex. CONCLUSION: Peritoneal dialysis patients generally have marginal serum albumin levels, a finding incongruent with alternative measures of nutritional status, such as weight, BMI, and creatinine generation. Serum albumin is reduced in patients with high peritoneal permeability (i.e., rapid transporters) and, because these patients generally have higher than average wCCr values, serum albumin is inversely correlated with the dialysis component of the wCCr. The presumptive nutritional indicators (BMI, %LBM, nPNA, and serum albumin) provide disparate estimates, varying from 10% to 50% for the prevalence of nutritionally stressed PD patients.

Adult↗

24-hour dialysate collection for determination of peritoneal membrane transport characteristics: longitudinal follow-up data for the dialysis adequacy and transport test (DATT).

OBJECTIVE: To determine the ability of the dialysis adequacy and transport test (DATT) to monitor changes in peritoneal transport characteristics over time. SETTING: University-based peritoneal dialysis program. PATIENTS: One hundred patients on continuous ambulatory peritoneal dialysis who underwent 226 simultaneous DATTs and peritoneal equilibration tests (PET). METHODS: Retrospective analysis of DATT and PET data. RESULTS: The mean 24-hour dialysate-to-plasma creatinine (cr) concentration ratio (D/P cr) from the DATT was 0.70 +/- 0.10, and the mean four-hour D/P cr from the PET was 0.68 +/- 0.10. The correlation coefficient between the four-hour and 24-hour D/P cr was 0.81, and the standard error of estimate was 0.065. The mean (+/- SD) difference between the four-hour and 24-hour D/P cr was 0.023 +/- 0.061. Fifty-eight patients had two or more sequential DATTs and PETs. For these 94 sets of sequential DATTs and PETs, the mean (+/- SD) difference between the change in the four-hour D/P cr and the change in the 24-hour D/P cr was 0.020 +/- 0.024, and the standard error of estimate was 0.064. In 17 patients a change in dwell volume from 2.0 L to 2.5 L occurred between the first and second measures of peritoneal membrane transport characteristics. The mean (+/- SD) difference between the change in the four-hour D/P cr and the change in the 24-hour D/P cr was 0.036 +/- 0.055, and the standard error of estimate was 0.087. CONCLUSION: The DATT can be used to monitor for changes in peritoneal transport over time. It should not be used in patients receiving cycler therapy or in patients whose dwell times and dextrose concentrations vary markedly from day to day.

Biological Transport↗

Body surface area limitations in achieving adequate therapy in peritoneal dialysis patients.

OBJECTIVE: To estimate the maximal body surface area (BSA) at which anuric chronic peritoneal dialysis patients can achieve adequate peritoneal dialysis using a variety of continuous ambulatory peritoneal dialysis (CAPD) and cycler regimens. Adequate dialysis was defined as a creatinine clearance of either 60 L/week/1.73 m2 or 70 L/ week/1.73 m2. DESIGN: Calculation of daily peritoneal creatinine clearances using standard formulas. For CAPD patients, creatinine clearance was calculated using published values for dialysate-to-plasma ratios for creatinine (D/P cr) measured over a 24-hour period and assuming a daily ultrafiltration rate of 1.5 to 2.0 L/day. For cycler patients, creatinine clearance was calculated for both one- and two-hour dwell volumes, using published values for D/P cr from the peritoneal equilibration test and assuming a daily ultrafiltration rate of 2.0 L/day. All clearances were corrected to a normalized body surface area of 1.73 m2. RESULTS: For CAPD patients, 2-L dwell volumes can provide a weekly creatinine clearance of 60 L/week/1.73 m2 in patients with BSA < 1.45 m2 in the high transporter group and with BSA < 1.2 m2 in the low-average transporter group. Increasing dwell volume from 2.0 to 2.5 L increases these BSA limits in the four transport groups by 0.2-0.3 m2. Cycler therapy is not a viable option for patients in the low transporter group, and this therapy can achieve adequate creatinine clearances in patients in the low-average transport group only with large dwell volumes and in patients with BSA < 1.55 m2. However, in the high-average and high transporter groups, cycler therapy provides for superior creatinine clearances compared to CAPD patients using similar dwell volumes. CONCLUSIONS: Adequate creatinine clearances in anuric patients are most likely to be achieved in patients with BSA > 2.0 m2 if they have high-average or high transport characteristics and are receiving cycler therapy with large dwell volumes and at least one daytime dwell. However, adequate creatinine clearances may be difficult to achieve in anuric patients who have a large BSA and a low or low-average transport type, regardless of peritoneal dialysis modality. These patients should be considered for either high-dose peritoneal dialysis (multiple daytime and nighttime exchanges) or hemodialysis therapy.

Body Surface Area↗

1996 Peritoneal Dialysis Core Indicators Study: report on nutritional indicators.

OBJECTIVE: The 1996 Peritoneal Dialysis Core Indicators Study illustrates the conduct of peritoneal dialysis in the United States during 1996. DESIGN AND PATIENT POPULATION: The survey is a medical records audit of 1317 randomly selected adult U.S.A. Medicare patients using peritoneal dialysis during 1996. OUTCOME MEASURES: Abstracted data included basic demographic characteristics, dialysis prescription, delivered dialysis dose, residual renal function, serum albumin, hematocrit, anemia management, and patient status. RESULTS: The survey included 785 patients using continuous ambulatory peritoneal dialysis (CAPD) and 423 using automated peritoneal dialysis (APD) primarily in the form of continuous cycling peritoneal dialysis (CCPD). Except for the prescription mechanics and a greater likelihood that African-Americans would use CAPD, the groups did not differ substantially from one another. Evaluation of patient weight (W), body mass index (BMI), residual renal function, average serum albumin, protein equivalent of nitrogen appearance (nPNA), and dialysis efficiency as weekly fractional urea nitrogen removal (wKt/Vurea) and weekly creatinine clearance (wCrCl) revealed a picture of reasonable dialysis delivery and marginal protein nutrition. Additionally, there was little evidence that "dialysis efficiency," over the range assessed, had a major influence on nutritional status. Despite a tendency toward obesity (body weight = 76.6+/-20.0 kg and BMI = 27+/-7), 47% of patients had an average serum albumin below"normal" (3.5 g/dL by bromcresol green) and 70% had a nPNA below 1.0 g/kg/day. CONCLUSIONS: Peritoneal dialysis patients appear to have marginal protein reserves despite surfeit energy stores.

Adult↗