PubMed Health⌕ Search

Biomedical subjects

M V Swain

Publications and source records attributed to M V Swain.

At least 19 recordsLinked to original sources

Functional significance of strain distribution in the human mandible under masticatory load: numerical predictions.

A common feature of studies of mandibular morphology is the assumption that there is some functional relation between the form of the lower jaw and masticatory stress. It was noted that the local variation in cortical bone thickness in the mandibular corpus appears to be stereotypical among anthropoids. This occurs at sections under the molars, where the lingual cortical plate is thinner than buccal one. In this study we investigate and contrast the strain pattern along buccal and lingual surfaces of the mandibular corpus during mastication using a numerical model of a human mandible. We show that strain distribution differs in alveolar and mid-corpus segments of the mandible and that the latter develops an alternate pattern between the buccal and lingual aspects of the working and balancing sides of the jaw. We then relate the magnitude of these strains to Frost's mechanostat. Our results suggest that the cortical asymmetry of the human mandible is in fact not related to strain patterns generated during mastication.

Adult↗

Modelling of fracture behaviour in biomaterials.

One of the most frequent causes of degradation and failure of quasi-brittle biomaterials is fracture. Mechanical breakdown, even when not catastrophic, is of particular importance in the area of biomaterials, as there are many clinical situations where it opens the path for biologically mediated failures. Over the past few decades the materials/biomaterials community has developed a number of numerical models, but only with limited incorporation of brittle failure phenomena. This article investigates the ability of a non-linear elastic fracture mechanics (NLEFM) model to reliably predict failure of biomaterials with a specific focus on the clinical settings of restorative dentistry. The approach enables one to predict fracture initiation and propagation in a complex biomechanical status based on the intrinsic material properties of the components. In this paper, we consider five examples illustrating the versatility of the present approach, which range from the failure of natural biomaterials, namely dentine and enamel, to a restored tooth, a three unit all ceramic bridge structure and contact-induced damage in the restorative layered materials systems. It is anticipated that this approach will have ramifications not only to model fracture events but also for the design and optimisation of the mechanical properties of biomaterials for specific clinically determined requirements.

Biocompatible Materials↗

Influence of the bonder on the adhesion of porcelain to machined titanium as determined by the strain energy release rate.

OBJECTIVE: To determine the adhesion at the titanium-porcelain interface using a fracture mechanics approach, and to investigate the bonding mechanism using SEM. METHODS: Specimens of five different titanium-porcelain and one base metal-porcelain bonding systems were prepared for a four-point bending interfacial delaminating test on a universal testing machine. The pre-cracked specimen was subjected to load and the strain energy release rate (G, J/m(2)) was calculated from the critical load to induce stable crack extension in each system. The interface for the various materials was investigated in an SEM and compared. RESULTS: The titanium-porcelain with Gold Bonder showed the highest G-value (72.39+/-13.21J/m(2)) among the groups whilst titanium-porcelain with cross-cut-bur preparation showed the lowest (5.78+/-1.39J/m(2)). The former was significantly higher than that of Wiron 99 (base-metal, BEGO, Germany) porcelain (40.01+/-6.67J/m(2)), a clinically accepted bonding system for many years. The G-values of porcelain fused to titanium-Rocatec, titanium-sandblasted and/or titanium-GC-Bonder were 10.81+/-1.49, 12.64+/-3.01 and 35.74+/-5.20J/m(2), respectively. SEM images of the interface fracture crack path for the different bonders enabled the mechanisms responsible for the differences in strain energy release rates to be appreciated. CONCLUSION: The strain energy release rate (G) of titanium-porcelain with a Gold Bonder interface layer was highest among the five different systems.

Adhesives↗

Mechanical evaluation of cervical glass-ionomer restorations: 3D finite element study.

OBJECTIVES: The aim of this paper was to investigate the influence of lesion shape and depth as well as the direction of occlusal loading on the mechanical response of cervical GIC restorations. METHODS: A finite element model of a lower first premolar was created. Both wedged and rounded lesions were then modelled with incremental depth after which the tooth was loaded at different angles. First principal stress (tension) was employed as an indicator of material failure, by contrasting our calculated stresses with the ultimate tensile strength of the GIC and known values of bond strength between material and tooth substrate. RESULTS: Obliquely loaded teeth exhibited significantly higher tensile stress in the cervical region of the restoration. For forces inclined at angles of 30 degrees and higher to the vertical tooth axis, the tensile stresses in the cervical margin of the restoration exceeded the ultimate material and bond strength. In contrast, lesion shape and depth have only a minor influence on tensile stress development. CONCLUSIONS: Lesion depth and shape are not of primary concern from a mechanical perspective for a restorative treatment decision. By contrast, occlusal diagnosis and subsequent re-adjustments of tooth contacts do form a critical part of the treatment of non-carious cervical lesions (NCCLs).

Dental Materials↗

A randomised clinical trial to investigate bond failure rates using a self-etching primer.

This clinical trial evaluated, over a 12-month period, the performance of brackets bonded to teeth etched and primed with Transbond Plus Self-Etching Primer (SEP) when compared with a conventional separate two-step etch and primer system. Thirty-nine randomly selected patients requiring fixed appliance therapy were entered into the study. Random allocation of each etching system, along with a 'split-mouth cross-quadrant' design was used. A total of 661 brackets were placed by two operators. The failure and survival rates of the brackets were determined for age and gender of the patients, each etching system, operator, mode of failure, tooth position in the dental arch, and number of manipulations prior to curing the adhesive. Statistical analysis showed that SEP had a significantly higher bond failure rate (11.2 per cent) than the conventional etch and primer system (3.9 per cent) at the P = 0.001 level. Cox's proportional hazards regression showed the conventional etch and primer system to have a 60 per cent reduced chance of bracket failure over a 12-month observation period, while males had a 2.4 times increased risk compared with females. The predominant mode of failure was at the composite enamel interface for the SEP, while for the conventional etch and primer system, it was within the composite adhesive. No statistically significant differences were found for the failure rate with respect to the age of the patient, operator, tooth location, or the number of manipulations of the bracket. This in vivo study showed that brackets bonded using SEP had an increased clinical bond failure rate compared with the conventional, separate, etch and prime system.

Adolescent↗

Changes in the physical properties of human premolar cementum after application of 4 weeks of controlled orthodontic forces.

This study was performed to assess the relationship between the magnitude of orthodontic force and physical properties of individual human cementum, and to identify the sites that may be predisposed to root resorption. The findings may assist in relating physical properties of dental root cementum and its susceptibility to root resorption. Sixteen maxillary first premolar teeth were selected in eight orthodontic patients (three males and five females), mean age 14.8 years (range 11.2-17.5 years), requiring first premolar extractions. In each patient, a light orthodontic force of 25 cN was applied buccally using a sectional archwire on the first premolar on one side, while a heavy force of 225 cN was applied to the contralateral side. The teeth were extracted 4 weeks after initial force application. Hardness and elastic modulus were measured on the buccal and the lingual surfaces of the cementum at the cervical, middle, and apical third of the root. The results showed that the mean hardness and elastic modulus of cementum in the light force group were greater than in the heavy force group at all positions. There were highly significant differences in both hardness and elastic modulus between the heavy and light force groups (P < 0.01). The mean hardness and elastic modulus of cementum gradually decreased from the cervical to the apical regions for buccal as well as lingual surfaces in both groups. There was, however, an insignificant difference between hardness and elastic modulus on the buccal surface compared with the lingual surface (P < 0.05). It was concluded that the hardness and elastic modulus of cementum were affected by the application of orthodontics forces.

Adolescent↗

Influence of water, loading rate and bonder on the adhesion of porcelain to titanium.

OBJECTIVES: The aim of this study was to measure the influence of water on the adhesion between titanium and porcelain by means of the strain energy release rate (G-value or interfacial toughness). METHODS: Rectangular specimens of grade II titanium and a reference gold-palladium porcelain fused to metal (PFM) alloy were veneered with feldspathic porcelains. In the case of the titanium, two gold and one ceramic bonder systems were used to enhance the adhesion of the porcelain. The G-value was measured with a four-point bending configuration developed by Charalambides et al. (Journal of Applied Mechanics (Trans ASME). 1989;56:77-82), at four different loading rates (from 0.1 to 15 N/s) in water and at one loading rate (1.5 N/s) in kerosine. RESULTS: There was a significant difference (ANOVA, p<0.01) in the interfacial toughness between the different bonding systems, with the two goldbonder systems exhibiting higher toughness in kerosine and water than the ceramic bonder. The two goldbonders achieved the best results across all loading rates. Their interfacial toughness, tested in kerosine, varied between 45.83+/-6.72 and 73.54+/-17.01 J/m(2) and tested in water from 40.86+/-2.23 to 69.17+/-12.33 J/m(2), respectively. The ceramic Ti bonder achieved the lowest G-values throughout (30.15+/-5.52 J/m(2) in kerosine to 11.08+/-2.18 J/m(2) in water). The gold-palladium PFM alloy showed more constant behaviour (33.48+/-2.24 J/m(2) to 23.07+/-0.53 J/m(2) in kerosine and water, respectively). CONCLUSION: Compared to the gold-palladium PFM alloy, the goldbonders achieved much higher G-values whereas the ceramic Ti bonder G-values were lower when tested in water and in kerosine.

Adhesiveness↗

Behaviour of primary incisor caries: a micromechanical study.

OBJECTIVES: To date, there has been no attempt to assess the mechanical properties of the entirety of a smooth-surface carious lesion in primary teeth, despite the fact that these lesions are not only common, but clinically challenging. Therefore, the aim of this study was to describe the hardness and modulus of elasticity across smooth surface lesions of primary incisors. STUDY DESIGN: An in vitro study of the micromechanical properties of primary incisors. MATERIALS AND METHODS: Carious primary incisor teeth were set in resin, sectioned and polished. A series of indentations using the ultra-micro-indentation system were conducted in fully hydrated carious and sound dentine from the minimally affected pulpal region towards the tooth surface. A single set of indentations were duplicated for sound dentine. RESULTS: Although the mechanical properties of the carious dentine varied between the test teeth, the median hardness of the surface, middle and inner (pulpal) region of the carious dentine was 0.01, 0.10 and 0.28 GPa, respectively. The modulus of elasticity of the surface, middle and inner (pulpal) carious dentine was 0.12, 2.16 and 5.98 GPa, respectively. The mechanical properties of the sound dentine varied less, and were consistent between the pulpal and surface regions. Examination of the individual series of indentations indicated that, although the majority of the test teeth showed a decrease in the mechanical properties from the 'unaffected dentine' to the surface of the lesion, in the last 300-500 microm, both the hardness and modulus of elasticity showed a dramatic increase. CONCLUSIONS: This study has confirmed that the carious process has a deleterious effect on the mechanical properties of dentine in primary incisors. This, in turn, increases the likelihood of restorative failure. However, the slight increase in mechanical properties seen at the surface of the carious lesion suggests an increase in mineral content.

Biomechanical Phenomena↗

Mandibular stiffness in humans: numerical predictions.

The chin is a feature unique to humans. This study evaluates the effect of mandibular symphyseal design on biomechanical masticatory effectiveness as determined by structural stiffness and stress developed under flexural and torsional loading. A simple model of three symphyseal shapes (chin, flat symphysis and lingual buttress), was built to represent human, Neanderthal and higher primate symphyses and these were subjected to wishboning and torsional forces. Additionally, an anatomically detailed reconstruction was made of the CT scan of an actual human mandible, which was then also morphed into a chinless model. The results of a 3-D finite element analysis show firstly, that none of the three different symphyseal shapes is biomechanically more advantageous than the others for the given loading condition. Secondly, we show in a CT-derived model, that the presence of a chin does not confer significantly improved stiffness to torsional or flexural loading. These results indicate that the acquisition of a chin in modern humans is not related to the functional demands placed upon the mandible during mastication, but suggest that it may have developed in response to other biomechanical demands.

Animals↗

Hydroxyapatite-coated metals: interfacial reactions during sintering.

Electrophoretic deposition (EPD) is a low cost flexible process for producing HA coatings on metal implants. Its main limitation is that it requires heating the coated implant in order to densify the HA. HA typically sinters at a temperature below 1150 degrees C, but metal implants are degraded above 1000 degrees C. Further, the metal induces the decomposition of the HA coating upon sintering. Recent developments have enabled EPD of metathesis-synthesised uncalcined HA which sinters at approximately 1000 degrees C. The effects of temperature on HA-coated Ti, Ti6Al4V, and 316L stainless steel were investigated for dual coatings of metathesis HA sintered at 1000 degrees C. The use of dual HA coatings (coat, sinter, coat, sinter) enabled decomposition to be confined to the "undercoat" (HA layer 1), with the surface coating decomposition free. The tensile strength of the three metals was not significantly affected by the high sintering temperatures (925 degrees C < T < 1000 degrees C). XRD/SEM/EDS analyses of the interfacial zones revealed that 316L had a negligible HA:metal interfacial zone (approximately 1 microm) while HA:Ti and HA:Ti6Al4V had large interfacial zones (>10 microm) comprising a TiO2 oxidation zone and a CaTiO2 reaction zone.

Alloys↗

The influence of Goldbonder and pre-heat treatment on the adhesion of titanium alloy and porcelain.

The present study examines the influence of a goldbonder and pre-heat treatment of the titanium on the adhesion of porcelain. Three groups of titanium substrates were given various heat treatments, namely; none, 200 degrees and 600 degrees C, respectively before applying goldbonder. The surfaces of the titanium specimens following heat treatment were examined with an electron spectroscopy for chemical analysis (ESCA). The adhesion strength was measured by the strain energy release rate (G), which was proposed by Suansuwan N and Swain MV (Int J Prosthodont. 1999;12:547). After bonding porcelain onto titanium substrates with the aid of the goldbonder, the porcelain side of specimens was notched to the interface with a thin diamond saw. Then the samples were subject to a four-point bending test. Following fracture testing, specimens were examined with a scanning electron microscope (SEM) and SEM with energy-dispersive spectroscopic analysis (EDS). The mean G-values were 38.87, 28.64 and 16.33 J m(-2), respectively. ESCA analysis showed the composition of aluminium of the surface of 600 degrees C pre-heat treatment became richer than that of the others. SEM images of the fracture surfaces showed that for the 600 degrees C pre-heat treatment fracture occurred within the oxidation layer on the titanium. High temperature pre-heat treatment prior to bonding significantly reduces porcelain bonded to titanium with the goldbonder. The Influence of Goldbonder and Pre-heat Treatment on the Adhesion of Titanium Alloy and Porcelain.

Adhesiveness↗

Fibre reinforced composite dental bridge. Part I: Experimental investigation.

This experimental investigation aims at revealing the mechanical behaviour and failure pattern of direct fibre-reinforced resin-bonded dental bridge with various designs. To evaluate the overall effects of some newly developed dental materials, in the experiment, genuine composite dental bridge specimens are prepared and tested. The ultimate load, stiffness and mode at the failure of the bridges are measured and compared with the design variations. A good agreement between test and some clinical observations is demonstrated. It is verified that the weakest region appears across the pontic-abutment interface in the composite bridges. This study suggests that the composite bridges reinforced by fibres and supported by adjacent teeth could be of a higher structural strength and stiffness; therefore would provide better clinical performances.

Composite Resins↗

Fibre reinforced composite dental bridge. Part II: Numerical investigation.

Motivated by the clinical success and limitations on experimental investigation of the fibre-reinforced composite dental bridge, this paper aims at providing a numerical investigation into the bridge structure. The finite element (FE) model adopted here is constructed from computer tomography images of a physical bridge specimen. The stress and strain distributions in the bridge structure especially in the bonding interfaces are analyzed in detail. The peak stresses and their variations with the different bridge designs are evaluated. Due to the lower bond strengths of adhesives and the high stress concentration in the pontic-abutment interface, the likelihood of failure in the interface is predicted by finite element analysis. The validity of the numerical results is established by a good agreement between the FE prediction and the tests in the load-deflection responses, the structural stiffness as well as the failure location of the composite dental bridge.

Composite Resins↗

Mechanical properties and microstructure of hypomineralised enamel of permanent teeth.

Isolated enamel defects are commonly seen in first permanent molar teeth but there has been little work on the physical and morphological composition of affected molars. The aim of this study was to determine the mechanical and morphological properties of hypomineralised first permanent molar teeth, utilising the Ultra-Micro-Indentation System (UMIS) and scanning electron microscope, respectively. Further investigations using Energy Dispersive X-ray Spectrometery (EDS), Back Scatter Electron (BSE) Imaging, and X-ray diffraction were employed to attempt to determine the chemical composition, mineral content and crystalline structure of the hypomineralised tissue, respectively, of eight first permanent molars with severe enamel hypomineralisation. The hardness and modulus of elasticity were found to be statistically significantly lower (0.53+/-0.31 and 14.49+/-7.56 GPa, respectively) than normal enamel (3.66+/-0.75 and 75.57+/-9.98 GPa, respectively). Although the fractured surface of the hypomineralised enamel was significantly more disorganised and the relative mineral content was reduced by approximately 5% in comparison to sound enamel, the mineral phase and Ca/P ratio was similar in hypomineralised and sound enamel. The dramatic reduction in the mechanical properties of first permanent molar teeth has ramifications when clinicians are choosing restorative materials to restore the defects. The reason for the dramatic reduction in mechanical properties of hypomineralised first permanent molar teeth is at present unknown.

Absorptiometry, Photon↗

The effect of Goldbonder on the adhesion between porcelain and pure titanium.

The present study examines the effect of a Goldbonder on the adhesion between titanium and porcelain as measured by the strain energy release rate (G) associated with the interfacial fracture of porcelain and titanium. The influence of surface treatment of titanium prior to Goldbonder application was also examined. The porcelain side of the specimens was notched to the interface with a thin diamond saw, and then a pre-crack was made at the metal-porcelain interface by a special jig. The samples were subjected to a four-point bending test resulting in stable crack extension from which G was calculated. Both the cracked cross-section of interface and peeled fracture surface were examined with scanning electron microscope (SEM). The mean G values were 81.57 +/- 10.34, 46.01 +/- 14.83, and 15.98 +/- 1.76 J m(-2) for the sandblasted surface with the Goldbonder, polished surface with the Goldbonder, and sandblasted surface with the Pastebonder, respectively. The G values revealed significant differences (P < 0.01) between Goldbonder and Pastebonder, and between the sandblasted and polished surfaces with Goldbonder. The SEM photographs and elemental analysis showed that Goldbonder developed both chemical and mechanical bonding to titanium and porcelain.

Dental Bonding↗

Root resorption and its association with alterations in physical properties, mineral contents and resorption craters in human premolars following application of light and heavy controlled orthodontic forces.

OBJECTIVES: To study the effect of different orthodontic force levels on cementum, investigating from the point of view of its physical properties, alterations in the mineral components, type and location of the resorption craters and the exploration in 3D of space. DESIGN: In vivo human premolars subjected to heavy and light forces were employed for this study. After a period of movement they were analyzed for hardness and elasticity. Also, the mineral composition measuring Ca, P and F of the cementum root surface was investigated. A new method for volumetric analysis of resorption craters was developed. RESULTS: There were no significant differences for hardness and elastic modulus between the light and heavy force groups and no significant effects for different tooth positions. Significant inter-individual variation in the Ca, P and F concentrations was noted. Force-related data showed that mean volume of the resorption crater in light-force group was 3.49-fold greater than the control group, and the heavy-force group 11.59-fold more than control group. The heavy force group had 3.31-fold greater total resorption volume then light force group. Buccal cervical and lingual apical regions demonstrated significantly more resorption craters than the other regions. The 2D measurements were strongly correlated to 3D measurements. CONCLUSION: The application of light and heavy forces did not show any statistically significant differences in hardness and elastic modulus when compared with untreated teeth. The inconsistent increase or decrease of Ca, P and F contents between control and experimental teeth at sites of compression and tension were difficult to explain. There was more resorption by volume in the heavy force group as compared with the light group and controls. Our data also suggested that the high-pressure zones might be more susceptible to resorption after 28 days of force application.

Adolescent↗

Comparison of failure characteristics of a range of cancellous bone-bone cement composites.

Over the past decade, orthopedic surgery has embraced an increase in the depth of cement penetration into the adjacent cancellous bone structure. The resultant interdigitation transforms this zone into a thick layer of continuous interpenetrating composite material. The failure behavior of the composite formed with a number of potential bone cements with different bonding ability was investigated. The cancellous bone-cement composites exhibit considerable resistance to crack extension, and in situ optical observation indicates that the contribution of the cancellous bone is analogous to that of a typical fiber bridging process. The critical stress intensity factor and the work of fracture have been used to quantify the failure characteristics of the cancellous bone-cement composites. The nature of the crack propagation through these cement-bone composites was also captured via optical microscopy, and scanning electron microscopic images were taken of the failure surfaces. The R-curve behavior, or crack extension characteristic, of the cancellous bone-cement composite was also determined. The interesting outcome is that the cancellous bone-PMMA (poly-methylmethacrylate) composite, despite the absence of chemical bonding with bone, required the highest energy to fracture. In addition, the dimensional stability of the cement has a great effect on the interface.

Animals↗

Topical administration of the nitric oxide donor glyceryl trinitrate modifies the structural and biomechanical properties of ovine articular cartilage.

OBJECTIVE: To examine the effect of topical administration of glyceryl trinitrate (GTN), an exogenous nitric oxide (NO) donor, on the structural and biomechanical properties of uncalcified articular cartilage (UCC) in aged ewes. DESIGN: Twelve ewes were used for this study. Six of these were treated with 2% GTN ointment (0.7 mg/kg) twice per week (GTN), and the remaining six were used as normal controls (NOC). After sacrifice at 26 weeks, dynamic biomechanical indentation testing and thickness determination (by needle penetration) were performed on tibial plateau articular cartilage at 18 locations. Using histological sections prepared from the lateral and medial femoral condyles (LFC, MFC) and tibial plateau (LTP, MTP), the thickness of UCC, cartilage proteoglycan content (intensity of toluidine blue staining; LFC, MFC only), and collagen birefringence (LTP, MTP, LFC only) were quantified by computer-assisted image analysis. RESULTS: Phase lag of tibial plateau cartilage was reduced in GTN sheep relative to NOC (mean of all testing locations 11.0+/-1.9 degrees vs 12.1+/-2.3 degrees; P=0.0001). GTN treatment also globally reduced UCC thickness across the joint (ANOVA for all measured zones, P<0.0001). UCC thinning was most pronounced in the MFC (P=0.025) and LTP (P=0.0002). Proteoglycan content was reduced in the MFC(P=0.019), while collagen birefringence was increased in superficial cartilage zones of the LTP. CONCLUSIONS: NO donation via topical administration of GTN to normal ewes reduced the thickness and phase lag of femoro-tibial articular cartilage, suggesting a disturbance in chondrocyte metabolism. Regional alterations of collagen organisation and proteoglycan content were consistent with this interpretation.

Administration, Topical↗