PubMed Health⌕ Search

Biomedical subjects

M W LeChevallier

Publications and source records attributed to M W LeChevallier.

36 records · Page 2Linked to original sources

Health significance and occurrence of injured bacteria in drinking water.

Enteropathogenic and indicator bacteria become injured in drinking water with exposure to sublethal levels of various biological, chemical and physical factors. One manifestation of this injury is the inability to grow and form colonies on selective media containing surfactants. The resulting underestimation of indicator bacteria can lead to a false estimation of water potability. m-T7 medium was developed specifically for the recovery of injured coliforms (both "total" and fecal) in drinking water. The m-T7 method was used to survey operating drinking water treatment and distribution systems for the presence of injured coliforms that were undetected with currently used media. The mean recovery with m-Endo LES medium was less than 1/100 ml while it ranged between 6 and 68/100ml with m-T7 agar. The majority of samples giving positive results with m-T7 medium yielded no detectable coliforms with m-Endo LES agar. Over 95% of the coliform bacteria in these samples were injured. Laboratory experiments were also done to ascribe the virulence of injured waterborne pathogens. Enteropathogens including Salmonella typhimurium, Yersinia enterocolitica and Shigella spp. required up to 20 times the chlorine levels to produce the same injury in enterotoxigenic Escherichia coli (ETEC) and nonpathogenic coliforms. Similar results were seen with Y. enterocolitica exposed to copper. The recovery of ETEC was followed by delayed enterotoxin production, both in vitro and in the gut of experimental animals. This indicates that injured waterborne enteropathogenic bacteria can be virulent.

Chlorine↗

Interactions between heterotrophic plate count bacteria and coliform organisms.

Studies were initiated to investigate the interactions between heterotrophic plate count bacteria and coliform organisms. We used spiked samples to show that heterotrophic plate count bacteria could reduce coliform densities by more than 3 logs within 8 days. Some heterotrophic plate count bacteria were able to cause injury to the coliform population. A significant correlation (r = 0.66; P less than 0.05) was observed between the initial level of heterotrophic plate count bacteria and the rate of coliform decline. Competition for limiting organic carbon was hypothesized to be responsible for the observed effects.

Bacteria↗

Reduced virulence of Yersinia enterocolitica by copper-induced injury.

A sublethal concentration of copper (0.75 mg/liter) caused substantial injury (87 to 95%) of Yersinia enterocolitica serotype O:8 cells in 72 h at 4 degrees C without producing extensive cell death. Copper-injured cells had a higher 50% lethal dose in mice (2,700 CFU) than uninjured cells (150 CFU). This reduced virulence correlated with more rapid clearance of the injured cells from the blood of mice after intravenous inoculation. A possible role of the liver in this process was shown by significant cell accumulation in mouse livers when copper-injured Y. enterocolitica cells were administered, compared with uninjured bacteria. In vitro studies with isolated mouse liver membranes showed higher titers of aggregation with copper-injured cells than control cells. The in vitro aggregation reaction and blood clearance activity in vivo were abolished by sugars that are known to interact with a hepatic lectin. Our data suggest that copper-induced injury reduces the virulence of Y. enterocolitica and that the liver may be involved in nonimmune rapid clearance of the injured cells, probably by interaction with a hepatic lectin(s).

Animals↗

Changes in virulence of waterborne enteropathogens with chlorine injury.

We designed experiments to assess the effect of chlorine injury on the virulence of waterborne enteropathogens. Higher chlorine doses (0.9 to 1.5 mg/liter) were necessary to produce injured Yersinia enterocolitica, Salmonella typhimurium, and Shigella spp. than to produce injured enterotoxigenic Escherichia coli or coliform bacteria (0.25 to 0.5 mg/liter) in the test system used; 50% lethal dose experiments in which mice were used showed that injured Y. enterocolitica cells were 20 times less virulent than uninjured control cells (3,300 and 160 CFU, respectively). This decrease in virulence was not related to reduced attachment to Henle 407 intestinal epithelial cells, but could be related to a loss of HeLa cell invasiveness. In contrast, injured S. typhimurium and enterotoxigenic E. coli cells lost their ability to attach to Henle cells. These data show that some enteropathogens and coliform bacteria differ in their sensitivities to chlorine injury and that the virulence determinants affected by chlorine may vary from one pathogen to another.

Animals↗

Growth and persistence of pathogens on granular activated carbon filters.

Three enteric pathogens Yersinia enterocolitica O:8, Salmonella typhimurium, and enterotoxigenic Escherichia coli, were examined for their ability to colonize granular activated carbon (GAC) in pure cultures and in the presence of autochthonous river water organisms. All three organisms readily colonized sterile GAC and maintained populations of ca. 10(5) to 10(7) CFU g-1 for 14 days when suspended in sterile river water. Exposure of pathogen biofilms on GAC to unsterile river water resulted in a gradual decline in pathogens on the carbon (0.08 to 0.14 log day-1). When pathogens were introduced to sterile GAC in the presence of heterotrophic plate count organisms, they attached at levels similar to those in the pure cultures and then decreased (0.10 to 0.22 log day-1). When added with heterotrophic plate count bacteria to GAC supporting a mature biofilm of native river water bacteria, they attached at a lower level (1.0 X 10(4) to 4.6 X 10(4) CFU g-1) and decreased at a more rapid rate (0.11 to 0.70 log day-1).

Carbon↗

Evidence for the role of copper in the injury process of coliform bacteria in drinking water.

Low levels of copper in chlorine-free distribution water caused injury of coliform populations. Monitoring of 44 drinking water samples indicated that 64% of the coliform population was injured. Physical and chemical parameters were measured, including three heavy metals (Cu, Cd, and Pb). Copper concentrations were important, ranging from 0.007 to 0.54 mg/liter. Statistical analyses of these factors were used to develop a model to predict coliform injury. The model predicted almost 90% injury with a copper concentration near the mean observed value (0.158 mg/liter) in distribution waters. Laboratory studies with copper concentrations of 0.025 and 0.050 mg/liter in an inorganic carbon buffer under controlled conditions of temperature and pH caused over 90% injury within 6 and 2 days, respectively. Studies of the metabolism of injured Escherichia coli cells indicated that the respiratory chain is at least one site of damage in injured cells.

Cadmium↗

Evaluation of m-T7 agar as a fecal coliform medium.

m-T7 agar, designed to improve recoveries of injured total coliforms, was evaluated for its effectiveness as a fecal coliform medium. The time and temperature of preincubation were found to be crucial to the optimal recovery of fetal coliforms. Isolation rates for fecal coliforms on m-T7 agar from sewage effluents were the highest when plates were preincubated at 37 degrees C for 8 h before transfer to 44.5 degrees C for 12 h. The medium was found to produce consistently higher fecal coliform counts than all the other methods tested. Recoveries were 3.1 times greater than the standard m-FC method and 1.7 times greater than the two-layer enrichment, temperature acclimation procedure. Verification rates for fecal coliforms isolated on m-T7 agar averaged 89.0%, whereas verification rates for m-FC agar averaged only 82.8%. Both media isolated similar fecal coliform populations. The advantages of a single medium, highly effective for the isolation of both total and fecal coliforms, are discussed.

Agar↗

Disinfection of bacteria attached to granular activated carbon.

Heterotrophic plate count bacteria, coliform organisms, and pathogenic microorganisms attached to granular activated carbon particles were examined for their susceptibility to chlorine disinfection. When these bacteria were grown on carbon particles and then disinfected with 2.0 mg of chlorine per liter (1.4 to 1.6 mg of free chlorine residual per liter after 1 h) for 1 h, no significant decrease in viable counts was observed. Washed cells attached to the surface of granular activated carbon particles showed similar resistance to chlorine, but a progressive increase in sublethal injury was found. Observations made by scanning electron microscope indicated that granular activated carbon was colonized by bacteria which grow in cracks and crevices and are coated by an extracellular slime layer. These data suggest a possible mechanism by which treatment and disinfection barriers can be penetrated and pathogenic bacteria may enter drinking water supplies.

Adhesiveness↗

New medium for improved recovery of coliform bacteria from drinking water.

A new membrane filter medium was developed for the improved recovery of injured coliforms from drinking water. The new medium, termed m-T7, consists of 5.0 g of Difco Proteose Peptone no. 3, 20 g of lactose, 3.0 g of yeast extract, 0.4 ml of Tergitol 7 (25% solution), 5.0 g of polyoxyethylene ether W-1, 0.1 g of bromthymol blue, 0.1 g of bromcresol purple, and 15 g of agar per liter of distilled water. Additional selectivity may be obtained by aseptically adding 0.1 microgram of penicillin G per ml to the medium after autoclaving. In laboratory studies, m-T7 agar recovered 86 to 99% more laboratory-injured coliforms than did m-Endo agar. m-T7 agar also recovered an average of 43% more verified coliforms from 67 surface and drinking water samples than did the standard m-Endo membrane filter technique. From drinking water, m-T7 agar recovered nearly three times more coliforms than did m-Endo agar. Less than 0.5% of the colonies on m-T7 agar gave false-negative reactions, whereas greater than 70% of the typical yellow colonies from m-T7 agar produced gas in lauryl tryptose broth. Most of the verified coliforms isolated on m-T7 agar belonged to one of the four common coliform genera: Escherichia, 17.6%; Klebsiella, 21.7%; Citrobacter, 17.3%; Enterobacter, 32.2%. The results demonstrate that m-T7 agar is superior to m-Endo agar, especially for the isolation of injured coliforms from drinking water.

Citrobacter↗

Comparison of verification procedures for the membrane filter total coliform technique.

Verification of membrane filter total coliform colonies from drinking water was increased 87% by testing for the presence of beta-galactosidase and cytochrome oxidase, compared with verification by determination of gas production in lauryl tryptose broth. Over 90% of the coliforms verified by testing for beta-galactosidase and cytochrome oxidase were representative of the typical coliform genera.

Bacteriological Techniques↗

Influence of diluents, media, and membrane filters on detection fo injured waterborne coliform bacteria.

Pure cultures of Escherichia coli, Klebsiella pneumoniae, Enterobacter aerogenes, and Citrobacter freundii were injured ( greater than 90%) in water from a dead-end section of the Bozeman, Montana, distribution system. The effects of the following laboratory variables on the enumeration efficiency of injured and undamaged control cells were examined: (i) diluent composition, temperature, and time of exposure; (ii) media, using various formulations employed in enumerating gram-negative bacteria; and (iii) surface pore morphology of membrane filters. The addition of peptone or milk solids to diluents and low temperature (4 degrees C) maximized the recovery of injured cells, but had little effect on undamaged cells. Control cells were recovered with high efficiencies on most media tested, but recoveries of injured cells ranged from 0 to near 100%. Most of the media commonly used in water analysis recovered less than 30% of injured cells. This was explained in part by the sensitivity of injured bacteria to deoxycholate concentrations greater than 0.01%, whereas control cells were unaffected by 0.1%. Membrane filter surface pore morphology (at 35 degrees C) had a negligible effect on total coliform recoveries. Recommendations are made regarding procedures to improve the recovery of injured coliforms by routine laboratory practices.

Citrobacter↗

Failure of the most-probable-number technique to detect coliforms in drinking water and raw water supplies.

A procedure was developed to detect false-negative reactions (interference) in the standard most-probable-number (S-MPN) technique for coliform enumeration of untreated surface water and potable water supplies. This modified MPN (M-MPN) procedure allowed a quantitative assessment of the interference with coliform detection in untreated surface water and potable water supplies. Coliform interference was found to occur in the presumptive, confirmed, and completed tests of the S-MPN technique. When coliforms were present, interference with their detection occurred in over 80% of the samples. The inferior nature of the S-MPN was revealed by the 100% increase in the incidence of completed coliform-positive drinking water samples obtained with the M-MPN technique. The M-MPN procedure was also superior to the standard membrane filter technique. Eight different species of coliforms were recovered from false-negative tests, including Citrobacter, Enterobacter, Klebsiella, and Escherichia coli (in decreasing order of occurrence). The use of standard MPN techniques for monitoring potable water supplies may lead to a false security that the drinking water supply is potable, i.e., free from indicator bacteria.

Bacteriological Techniques↗

Coliform species recovered from untreated surface water and drinking water by the membrane filter, standard, and modified most-probable-number techniques.

The species of total coliform bacteria isolated from drinking water and untreated surface water by the membrane filter (MF), the standard most-probable-number (S-MPN), and modified most-probable-number (M-MPN) techniques were compared. Each coliform detection technique selected for a different profile of coliform species from both types of water samples. The MF technique indicated that Citrobacter freundii was the most common coliform species in water samples. However, the fermentation tube techniques displayed selectivity towards the isolation of Escherichia coli and Klebsiella. The M-MPN technique selected for more C. freundii and Enterobacter spp. from untreated surface water samples and for more Enterobacter and Klebsiella spp. from drinking water samples than did the S-MPN technique. The lack of agreement between the number of coliforms detected in a water sample by the S-MPN, M-MPN, and MF techniques was a result of the selection for different coliform species by the various techniques.

Bacteriological Techniques↗

Impact of verification media and resuscitation on accuracy of the membrane filter total coliform enumeration technique.

Verification of membrane filter total coliform colonies was compared in lauryl tryptose broth, and m-LAC broth primary media and brilliant green-lactose-bile broth and EC broth secondary media. Verification in m-LAC broth yielded the greatest number of aerogenic isolates for both untreated surface water and drinking water samples. Verification in brilliant green-lactose-bile broth increased the number of false-negative reactions. At least 90% of the isolates aerogenic in primary verification media and anaerogenic in brilliant green-lactose-bile broth were representative of the coliform genera. The addition of a resuscitation step in the membrane filter technique did not yield greater numbers of verified coliforms per sample. Verification of both typical and atypical colonies in m-LAC broth resulted in a 10-fold increase in coliform numbers from untreated surface water. With drinking water, verification of both colony types resulted in an increase from less than 1 coliform per 100 ml to greater than 1/100 ml. A single-step verification in m-LAC broth is proposed as a more rapid and sensitive coliform verification procedure than the standard technique.

Aerobiosis↗

Effect of turbidity on chlorination efficiency and bacterial persistence in drinking water.

To define interrelationships between elevated turbidities and the efficiency of chlorination in drinking water, experiments were performed to measure bacterial survival, chlorine demand, and interference with microbiological determinations. Experiments were conducted on the surface water supplies for communities which practice chlorination as the only treatment. Therefore, the conclusions of this study apply only to such systems. Results indicated that disinfection efficiency (log10 of the decrease in coliform numbers) was negatively correlated with turbidity and was influenced by season, chlorine demand of the samples, and the initial coliform level. Total organic carbon was found to be associated with turbidity and was shown to interfere with maintenance of a free chlorine residual by creating a chlorine demand. Interference with coliform detection in turbid waters could be demonstrated by the recovery of typical coliforms from apparently negative filters. The incidence of coliform masking in the membrane filter technique was found to increase as the turbidity of the chlorinated samples increased. the magnitude of coliform masking in the membrane filter technique increased from less than 1 coliform per 100 ml in water samples of less than 5 nephelometric turbidity units to greater than 1 coliform per 100 ml in water samples of greater than 5 nephelometric turbidity units. Statistical models were developed to predict the impact of turbidity on drinking water quality. The results justify maximum contaminant levels for turbidity in water entering a distribution system as stated in the National Primary Drinking Water Regulations of the Safe Drinking Water Act.

Chlorine↗

Bacterial contamination of drinking water supplies in a modern rural neighborhood.

On six occasions during a 15-month period, the private well and spring water supplies in a modern rural neighborhood of 78 households were examined for total coliforms, fecal coliforms, Staphylococcus aureus, and standard plate count bacteria. More than one-third of the water supplies were unsatisfactory on at least one occasion as judged by standard plate counts over 10(3)/ml and the presence of coliforms, fecal coliforms, and/or S. aureus. Citrobacter freundii, Klebsiella pneumoniae, and Escherichia coli were the most frequently isolated total coliforms. At least 12 other genera of bacteria were identified from standard plate count agar. Coliform contamination was found to be higher after periods of rainfall, and high standard plate counts were more prevalent during warmer weather. These observations probably reflect leakage of surface water into improperly sealed wells or aquifer contamination during winter and the lack of chlorination to control microbial regrowth during the warm season. An inverse correlation was found between the presence of high standard plate counts and incidence of coliforms. Consumer education and at least a twice yearly monitoring of private water supplies (winter and summer) are suggested methods to signal that treatment may be necessary to reduce the risk of waterborne disease.

Bacteria↗

Staphylococcus aureus in rural drinking water.

Coagulase-positive Staphylococcus aureus was isolated from over 6% of 320 rural drinking water specimens. Well water was the most common source examined. The presence of S. aureus was not found to correlate with the presence of coliform bacteria. Strains of Staphylococcus that produced enterotoxin A were found in 40% of the samples containing S. aureus. Additional studies showed that faucet aerator screens were common sources of high cell densities of S. aureus.

Enterobacteriaceae↗

Enumeration and characterization of standard plate count bacteria in chlorinated and raw water supplies.

Nearly 700 standard plate count (SPC) bacteria were isolated from drinking water and untreated surface water and identified according to a scheme developed to permit the rapid, simple classification of microorganisms to genus, species, or group. Actinomycetes and Aeromonas species were the two most common groups of SPC bacteria in chlorinated distribution water. Aeromonas spp. and Enterobacter agglomerans were the two most common groups of SPC bacteria in raw water. Identification of bacterial populations before and after contact with chlorine (1 to 2 mg/liter) for 1 h revealed that chlorination selected for gram-positive bacteria. Water that contained high densities of bacteria known to be antagonistic to coliforms had low coliform isolation rates. The membrane filtration technique for enumerating SPC bacteria recovered significantly higher numbers (P < 0.001) than the standard pour plate technique.

Actinomycetaceae↗