PubMed Health⌕ Search

Biomedical subjects

M Watzich

Publications and source records attributed to M Watzich.

3 recordsLinked to original sources

Aperture modulated arc therapy.

We show that it is possible to translate an intensity modulated radiation therapy (IMRT) treatment plan and deliver it as a single arc. This technique is referred to in this paper as aperture modulation arc therapy (AMAT). During this arc, the MLC leaves do not conform to the projection of the target PTV and the machine output of the accelerator has a constant value. Dose was calculated using the CORVUS 4.0 IMRT system, which uses a pencil beam dose algorithm, and treatments were delivered using a Varian 2100C/D Clinac. Results are presented for a head and neck and a prostate case, showing the equivalence of the IMRT and the translated AMAT delivery. For a prostate AMAT delivery, coronal plane film dose for the IMRT and AMAT deliveries agreed within 7.19 +/- 6.62%. For a meningioma the coronal plane dose distributions were similar to a value of 4.6 +/- 6.62%. Dose to the isocentre was measured as being within 2% of the planned value in both cases.

Algorithms↗

Bladder and rectal doses from external-beam boosts after gynecologic brachytherapy.

PURPOSE: To establish a typical value for radiation doses under pelvic midline shields. MATERIALS AND METHODS: Three methods were used to determine bladder and rectal doses under 5- or 6-half-value layer (HVL) shields for 10- and 24-MV external beams. First, dose was computed with a standard irregular field routine in 25 consecutive patients (aged 35-70 years) with stage IIB or IIIB disease treated with cesium-137 brachytherapy followed by a parametrial external-beam boost. Second, in vivo measurements with a solid-state probe were recorded during the first boost after completion of brachytherapy in each patient. Third, measurements obtained with an ionization chamber in a solid phantom (water-equivalent material) were compared with computed and in vivo results. RESULTS: All three dosimetric methods yielded bladder and rectal doses higher than the commonly assumed 5% of the unshielded primary beam dose. Doses within the shielded volume may be as high as 15% of the unshielded dose. Doses are similar under 5- and 6-HVL midline shields. Often, the actual bladder and rectal doses exceeded the planned dose limits and their corresponding maximum radiation dose tolerance levels. CONCLUSION: Bladder and rectal doses are higher than previously understood. Parametrial boosts may contribute as much as 3.0 Gy to the bladder and rectal doses.

Adult↗

A novel applicator for low-dose-rate brachytherapy of gynecological cancers.

The standard low-dose-rate (LDR) delivery system utilized in the definitive management of patients with cervical carcinoma involves an intrauterine tandem and a pair of vaginal colpostats (ovoids). This well-known application system may deliver inadequate dosage if the tumor extends to the lower vaginal mucosa. During the gauze packing of the ovoids, either operator error or narrowing of the vaginal apex can result in mal-alignment of the colpostats and subsequent inadequate dosing to the ecto-cervix. A novel vaginal cylinder has been designed to address these concerns. Beginning January 1, 2001, patients with cancer of the cervix, endometrium, or vagina requiring LDR brachytherapy have been enrolled into an institutionally sanctioned clinical trial. As of May 31, 2001, a total of 11 patients have been entered but only 10 were successfully implanted with the test device. Patient follow-up has ranged from 0.81 years to 1.2 years (median: 0.96 years). Using our study applicator, all patients received within 10% of the preimplant prescribed dose to tumor. Also, no one had cumulative dosage that exceeded 10% of the maximum allowed dose to the critical normal tissues. Thus far, all study patients have had no clinical evidence of persistence/recurrence of disease or complications from treatment. The preliminary results presented herein clearly demonstrate the feasibility of this novel LDR vaginal cylinder in the treatment of a variety of clinical situations involving gynecological cancers. Our institutional trial is continuing.

Adult↗