Emergence and spread of rifampicin-resistant, methicillin-resistant Staphylococcus aureus during vancomycin-rifampicin combination therapy in an intensive care unit.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Woolley.
Explore the source record for details and available documents.
The self-retaining urinary catheter is used for long-term drainage of urine from the bladder only as a last resort because of serious associated complications, yet it remains a routine method for managing older and disabled patients with loss of bladder control. Blockage of the catheter from calcified deposits within its lumen is a common occurrence, obstructing the passage of urine and causing an urgent, unpredictable problem for patients, carers and the nursing staff. The need for further research on the subject has been recognized for many years. The SuPort Project aimed to develop an alternative suprapubic urine collection system. This report outlines the approach adopted towards the design and selection of the novel device, the production problems that ensued and the small clinical trial of a modified prototype.
OBJECTIVE: To investigate reports from district nursing staff of difficulty in removing long-term urinary catheters (LTCs) because of the formation of a 'cuff' on deflating the self-retaining balloon. PATIENTS AND METHODS: Problems experienced by district nurses when removing urethral and suprapubic LTCs were audited, noting the type of problem, the catheter and any action taken. Quantitative in vitro studies were conducted on the deflated self-retaining balloons after incubating a similar range of catheters in saline at 37 degrees C for 6 weeks, using suprapubic profilometry to assess the resistance to withdrawal (retention force). RESULTS: Questionnaires were returned on 154 patients with LTCs; 56% had urethral and 44% suprapubic catheters. The catheters were hydrogel-coated (83%), all-silicone (13%) and PTFE-coated (3%). Twenty-two (14%) of the sample reported problems with catheter removal in the previous year, including 15 (68%) with all-silicone catheters and 15 (68%) with suprapubic catheters; cuff formation was noted in 60%. In the laboratory, 10 of the balloons formed a 'cuff' on deflation, but there was great variability in the effect this had on the retention force, with values of 0.5-3 N for different catheters. CONCLUSIONS: Most problems with catheter removal involved all-silicone and suprapubic catheters. Suprapubic profilometry confirmed increased resistance to withdrawal by formation of a 'cuff' on deflation of the balloon of all-silicone catheters. These results suggest that the first choice of catheter material for long-term urethral and suprapubic use should be hydrogel-coated latex.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
As managed care and government actions threaten the financial base of research and education at America's teaching hospitals, they must find new sources of funds. Mary Woolley of the advocacy group Research!America notes that the heads of healthcare systems can help reverse the downward trend in funding and gain a competitive edge with the public, who favor spending more on research.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.