PubMed Health⌕ Search

Biomedical subjects

M Y Menetrez

Publications and source records attributed to M Y Menetrez.

5 recordsLinked to original sources

Solvent comparison in the isolation, solubilization, and toxicity of Stachybotrys chartarum spore trichothecene mycotoxins in an established in vitro luminescence protein translation inhibition assay.

It is well known that non-viable mold contaminants such as macrocyclic trichothecene mycotoxins of Stachybotrys chartarum are highly toxinigenic to humans. However, the method of recovering native mycotoxin has been without consensus. Inconsistencies occur in the methods of isolation, suspension, preparation, and quantitation of the mycotoxin from the spores. The purpose of this study was to provide quantitatively comparative data on three concurrent preparations of 10(6)S. chartarum spores. The experiments were designed to specifically evaluate a novel method of mycotoxin extraction, solubilization, and the subsequent inhibitory effect in an established in vitro luminescence protein translation assay from 30 day-old spores. The mycotoxin-containing spores swabbed from wallboard cultures were milled with and without glass beads in 100% methanol, 95% ethanol, or water. Milled spore lysates were cleared of cell debris by filter centrifugation followed by a second centrifugation through a 5000 MWCO filter to remove interfering proteins and RNases. Cleared lysate was concentrated by centrivap and suspended in either alcohol or water as described. The suspensions were used immediately in the in vitro luminescence protein translation assay with the trichothecene, T-2 toxin, as a control. Although, mycotoxin is reported to be alcohol soluble, the level of translation inhibition was not reliably satisfactory for either the methanol or ethanol preparations. In fact, the methanol and ethanol control reactions were not significantly different than the alcohol prepared spore samples. In addition, we observed that increasing amounts of either alcohol inhibited the reaction in a dose dependent manner. This suggests that although alcohol isolation of mycotoxin is desirable in terms of time and labor, the presence of alcohol in the luminescence protein translation reaction was not acceptable. Conversely, water extraction of mycotoxin demonstrated a dose dependent response, and there was significant difference between the water controls and the water extracted mycotoxin reactions. In our hands, water was the best extraction agent for mycotoxin when using this specific luminescence protein translation assay kit.

Ethanol↗

Method for evaluating mold growth on ceiling tile.

A method to extract mold spores from porous ceiling tiles was developed using a masticator blender. Ceiling tiles were inoculated and analyzed using four species of mold. Statistical analysis comparing results obtained by masticator extraction and the swab method was performed. The masticator method was demonstrated as efficient for bulk sampling of ceiling tiles.

Colony Count, Microbial↗

Evaluating the potential efficacy of three antifungal sealants of duct liner and galvanized steel as used in HVAC systems.

Current recommendations for remediation of fiberglass duct materials contaminated with fungi specify complete removal, which can be extremely expensive, but in-place duct cleaning may not provide adequate protection from regrowth of fungal contamination. Therefore, a common practice in the duct-cleaning industry is the postcleaning use of antifungal surface coatings with the implication that they may contain or limit regrowth. However, even the proper use of these products has generally been discouraged because little research has been conducted on the effectiveness of most products as used in heating, ventilating, and air-conditioning (HVAC) systems. Three different coatings were evaluated on fiberglass duct liner (FGDL). Two of the three coatings were able to limit growth in the 3-month study; the third did not. One of the coatings that was able to limit growth was further evaluated in a comparison of FGDL or galvanized steel (GS) under conditions that mimicked their use in HVAC systems. The results showed that both moderately soiled and heavily soiled uncoated FGDL and GS duct material can support fungal growth, but that GS duct material was more readily cleaned. The use of an antifungal coating helped limit, but did not fully contain, regrowth on FGDL. No regrowth was detected on the coated GS.

Air Conditioning↗

Investigation of the potential antimicrobial efficacy of sealants used in HVAC systems.

Recent experiments confirm field experience that duct cleaning alone may not provide adequate protection from regrowth of fungal contamination on fiberglass duct liner (FGDL). Current recommendations for remediation of fungally contaminated fiberglass duct materials specify complete removal of the materials. But removal of contaminated materials can be extremely expensive. Therefore, a common practice in the duct-cleaning industry is the postcleaning use of antimicrobial surface coatings with the implication that they may contain or limit regrowth. Little information is available on the efficacy of these treatments. This paper describes a study to evaluate whether three commercially available antimicrobial coatings, placed on a cleaned surface that 1 year previously had been actively growing microorganisms, would be able to prevent regrowth. The three coatings contained different active antimicrobial compounds. All three of the coatings were designed for use on heating, ventilation, and air conditioning (HVAC) system components or interior surfaces of lined and unlined duct systems. Coating I was a polyacrylate copolymer containing zinc oxide and borates. Coating II was an acrylic coating containing decabromodiphenyl oxide and antimony trioxide. Coating III was an acrylic primer containing a phosphated quaternary amine complex. The study included field and laboratory assessments. The three treatments were evaluated in an uncontrolled field setting in an actual duct system. The laboratory study broadened the field study to include a range of humidities under controlled conditions. Both static and dynamic chamber laboratory experiments were performed. The results showed that two of the three antimicrobial coatings limited the regrowth of fungal contamination, at least in the short term (the 3-month time span of the study); the third did not. Before use in the field, testing of the efficacy of antimicrobial coatings under realistic use conditions is recommended because antimicrobials have different baseline activities and interact differently with the substrate that contains them and their local environment.

Air Conditioning↗

An analytical method for the measurement of nonviable bioaerosols.

Exposures from indoor environments are a major issue for evaluating total long-term personal exposures to the fine fraction (<2.5 microm in aerodynamic diameter) of particulate matter (PM). It is widely accepted in the indoor air quality (IAQ) research community that biocontamination is one of the important indoor air pollutants. Major indoor air biocontaminants include mold, bacteria, dust mites, and other antigens. Once the biocontaminants or their metabolites become airborne, IAQ could be significantly deteriorated. The airborne biocontaminants or their metabolites can induce irritational, allergic, infectious, and chemical responses in exposed individuals. Biocontaminants, such as some mold spores or pollen grains, because of their size and mass, settle rapidly within the indoor environment. Over time they may become nonviable and fragmented by the process of desiccation. Desiccated nonviable fragments of organisms are common and can be toxic or allergenic, depending upon the specific organism or organism component. Once these smaller and lighter fragments of biological PM become suspended in air, they have a greater tendency to stay suspended. Although some bioaerosols have been identified, few have been quantitatively studied for their prevalence within the total indoor PM with time, or for their affinity to penetrate indoors. This paper describes a preliminary research effort to develop a methodology for the measurement of nonviable biologically based PM, analyzing for mold and ragweed antigens and endotoxins. The research objectives include the development of a set of analytical methods and the comparison of impactor media and sample size, and the quantification of the relationship between outdoor and indoor levels of bioaerosols. Indoor and outdoor air samples were passed through an Andersen nonviable cascade impactor in which particles from 0.2 to 9.0 microm were collected and analyzed. The presence of mold, ragweed, and endotoxin was found in all eight size ranges. The presence of respirable particles of mold and pollen found in the fine particle size range from 0.2 to 5.25 microm is evidence of fragmentation of larger source particles that are known allergens.

Aerosols↗